| Allicdata Part #: | APL111-2REC4-5204-3-ND |
| Manufacturer Part#: |
APL111-2REC4-5204-3 |
| Price: | $ 0.00 |
| Product Category: | Circuit Protection |
| Manufacturer: | Sensata-Airpax |
| Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
| More Detail: | N/A |
| DataSheet: | APL111-2REC4-5204-3 Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1 +: | 0.00000 |
| Series: | APL |
| Part Status: | Obsolete |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Magnetic (Hydraulic Delay) |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | -- |
| Number of Poles: | 3 |
| Actuator Type: | Lever |
| Illumination: | -- |
| Illumination Voltage (Nominal): | -- |
| Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers serve as the foundation of any industrial or commercial building\'s electrical system. Providing protection from dangerous electrical problems, circuit breakers are an essential component in keeping a facility or building\'s electrical system running smoothly and safely. APL111-2REC4-5204-3 is a circuit breaker from ABB, which has a wide range of applications, as well as a unique working principle.
Applications of APL111-2REC4-5204-3 Circuit Breakers
The APL111-2REC4-5204-3 circuit breaker is designed for a variety of applications, including residential, commercial, and industrial applications. In residential applications, the circuit breaker can be used to protect a home from dangerous electrical surges and protect wiring from overloads. In a commercial building, it can be used to protect wiring from damage caused by power surges or sudden increases in electrical demand. In industrial settings, the circuit breaker can be used to protect high-voltage equipment from overloads and short circuits.
The circuit breaker is designed to handle a variety of voltages. It can be used with 120/240-volt AC single-phase systems, as well as with 115-volt AC three-phase systems. Additionally, the circuit breaker can also be used with 230-volt AC three-phase systems, making it a versatile choice for a variety of electrical system configurations.
Working Principle of APL111-2REC4-5204-3 Circuit Breakers
The APL111-2REC4-5204-3 circuit breaker utilizes ABB\'s patented magnetic field technology to provide protection from dangerous electrical overloads. This technology is based on the understanding that when current passes through a conductor, a magnetic field is generated around the conductor. This magnetic field is detected by the circuit breaker, which then trips the breaker when the field exceeds a certain level.
The circuit breaker also utilizes an internal temperature limit switch. This switch is designed to detect any sudden increases in temperature within the electrical system and trip the breaker should the temperature exceed a certain limit. This helps to prevent the circuit breaker from being overloaded and protects the wiring from overheating.
The APL111-2REC4-5204-3 circuit breaker is also designed with an automatic reset function. This feature helps the circuit breaker to reset itself after it has been tripped, allowing it to be quickly reused without having to be manually reset.
Conclusion
The APL111-2REC4-5204-3 circuit breaker is an essential component for any industrial or commercial building\'s electrical system. With its wide range of applications, as well as its unique working principle, the circuit breaker provides reliable protection from electrical problems. As such, it is an essential component for any building or facility\'s electrical system, providing protection from dangerous electrical overloads and short circuits.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| APL11-29426-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-20595-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1111-1REC2-6588-12 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11R-554-120 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-26469-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-4293-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-21568-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-31856-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-4301-10 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1669-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL13RE-468-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL14-1RE-564-21 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-4301-19 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-1REC4-2923-14 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1910-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-561-260 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1910-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1REC4-2920-29 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-6094-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1REC4-2920-34 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-22712-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-1690-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-8348-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-4088-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1RE-2659-02 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-21631-12 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-2831-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1REC4-2920-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-9253-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-1REC4-2920-50 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-30-5*429-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1911-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1111-25978-102 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111RR-1817-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-5114-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1669-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL111-2REC4-5204-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL11-4088-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1REC4-7906-8 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
| APL1-1REC4-7906-7 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
APL111-2REC4-5204-3 Datasheet/PDF