| Allicdata Part #: | 495-76166-ND |
| Manufacturer Part#: |
B88069X8170C203 |
| Price: | $ 1.51 |
| Product Category: | Circuit Protection |
| Manufacturer: | EPCOS (TDK) |
| Short Description: | GDT 250V 20% 10KA |
| More Detail: | Gas Discharge Tube 250V 10000A (10kA) ±20% 3 Pole ... |
| DataSheet: | B88069X8170C203 Datasheet/PDF |
| Quantity: | 2000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1 +: | $ 1.36710 |
| 5 +: | $ 1.30410 |
| 10 +: | $ 1.23921 |
| 50 +: | $ 0.99981 |
| 100 +: | $ 0.84767 |
| 250 +: | $ 0.82593 |
| 500 +: | $ 0.69552 |
| 1000 +: | $ 0.61945 |
| 5000 +: | $ 0.54338 |
| Series: | -- |
| Packaging: | Bulk |
| Lead Free Status / RoHS Status: | -- |
| Part Status: | Active |
| Moisture Sensitivity Level (MSL): | -- |
| Voltage - DC Spark Over (Nom): | 250V |
| Impulse Discharge Current (8/20µs): | 10000A (10kA) |
| Tolerance: | ±20% |
| Number of Poles: | 3 |
| Fail Short: | No |
| Mounting Type: | User Defined |
| Package / Case: | Cylinder No Lead, 3 Terminal |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are an important part of our power system electrical protection. Technically, GDT is a device used for limiting transient overvoltage and protecting electrical components from damage as a result of short-term overvoltage. This type of device consists of a glass or porcelain housing and two or more electrodes, as well as the components necessary for it to perform the intended purpose. B88069X8170C203 is a gas discharge tube arrester and it can be used in different application fields with specific working principles.
Application Field
The application field of B88069X8170C203 gas discharge tube arrester includes:
- Telecommunication: B88069X8170C203 can be used for voltage surge protection in digital transmission lines, signaling systems, and optical fiber networks. It can help to ensure the signal accuracy and quality of the transmission line, preventing the signal distortion and other communication errors.
- Automation: B88069X8170C203 can be used for voltage surge protection in automation systems, such as relay-type variable frequency drives, PLCs, HVAC systems, etc. This arrester provides a reliable protection against voltage surges and other disturbances in these systems, which can help to improve the system performance and extend the lifespan of the equipment.
- Power Supply Networks: B88069X8170C203 can be used for voltage surge protection in grid substations and other power supply systems. The arrester can protect the components of the system from high-voltage and can improve the safety of the system.
Working Principle
The working principle of B88069X8170C203 gas discharge tube arrester is based on the principles of attenuation and rectification. When an over voltage occurs, the arrester will act as an attenuator, reducing the voltage to a safe level. The attenuation is followed by a rectification process, which helps to limit the amount of current flowing through the overvoltage protection device. The attenuation and rectification processes work together to ensure that the device can efficiently and effectively provide protection from transient overvoltage.
B88069X8170C203 gas discharge tube arrester also offers protection from arc fault. The arrester is equipped with two electrodes, one of which is made of a spark retardant material. When the arc generated during an overvoltage passes through the spark retardant electrode, it is limited so that it can be safely dissipated, preventing it from damaging the equipment.
In addition, the device also has a self restorative function, which helps to restore the arrester to its original condition once the over voltage event has passed. This helps to ensure that the device is always ready to provide the necessary protection for the equipment.
Overall, B88069X8170C203 gas discharge tube arrester provides reliable protection against transient overvoltage, which can help to ensure the safety and reliability of our power systems.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| B88069X9410B502 | EPCOS (TDK) | -- | 1000 | GDT 350V 10KA T/H FAIL SH... |
| B88069X2040S102 | EPCOS (TDK) | 2.23 $ | 631 | GDT 680V 5KA THROUGH HOLE... |
| B88069X2780S102 | EPCOS (TDK) | 0.8 $ | 167 | GDT 500V 20% 2.5KA THROUG... |
| B88069X8920B252 | EPCOS (TDK) | 1.61 $ | 586 | GDT 230V 20% 20KA THROUGH... |
| B88069X7960B502 | EPCOS (TDK) | -- | 337 | GDT 420V 20% 10KA THROUGH... |
| B88069X4890C103 | EPCOS (TDK) | 0.99 $ | 975 | GDT 90V 20% 10KAGas Disch... |
| B88069X4420B152 | EPCOS (TDK) | 15.72 $ | 3 | GDT 2200V 20% 20KA THREAD... |
| B88069X4630C253 | EPCOS (TDK) | 0.8 $ | 2340 | GDT 350V 20% 5KAGas Disch... |
| B88069X8360C203 | EPCOS (TDK) | 1.51 $ | 1975 | GDT 90V 20% 10KAGas Disch... |
| B88069X8091B502 | EPCOS (TDK) | 0.78 $ | 401 | GDT 75V 1KA 2 POLE THROUG... |
| B88069X3880T502 | EPCOS (TDK) | 0.71 $ | 500 | GDT 1000V 15% 10KA THROUG... |
| B88069X4920S102 | EPCOS (TDK) | 1.06 $ | 2142 | GDT 350V 20% 10KA THROUGH... |
| B88069X2580S102 | EPCOS (TDK) | 3.02 $ | 500 | GDT 800V THROUGH HOLEGas ... |
| B88069X4180B502 | EPCOS (TDK) | 1.3 $ | 490 | GDT 300V 15% 2.5KA THROUG... |
| B88069X4230C101 | EPCOS (TDK) | 24.45 $ | 10 | GDT 3000V 25% 20KAGas Dis... |
| B88069X8680B502 | EPCOS (TDK) | 1.71 $ | 1000 | SURGE ARRESTER 230V GASTU... |
| B88069X3560T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
| B88069X1360C103 | EPCOS (TDK) | 1.65 $ | 798 | GDT 90V 20% 20KA THROUGH ... |
| B88069X0850T502 | EPCOS (TDK) | 0.41 $ | 1000 | GDT 230V 15% 5KA THROUGH ... |
| B88069X4530C102 | EPCOS (TDK) | 0.69 $ | 1000 | GDT 260V 15% 5KA THROUGH ... |
| B88069X7970B502 | EPCOS (TDK) | 0.8 $ | 1000 | T83-A420XF4Gas Discharge ... |
| B88069X1240B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
| B88069X2243T203 | EPCOS (TDK) | 0.28 $ | 1000 | GDT 500V 1KA 2 POLEGas Di... |
| B88069X8910B102 | EPCOS (TDK) | 0.76 $ | 1000 | 3 ELECT / 230VGas Dischar... |
| B88069X9370B502 | EPCOS (TDK) | 0.87 $ | 1000 | T23-A260XF4Gas Discharge ... |
| B88069X2010T502 | EPCOS (TDK) | 1.11 $ | 1000 | 2 ELECT / 470vGas Dischar... |
| B88069X6381T902 | EPCOS (TDK) | 0.29 $ | 1000 | GDT 150V 20% 2.5KA SURFAC... |
| B88069X3180C253 | EPCOS (TDK) | 0.48 $ | 1000 | GDT 350V 20% 10KAGas Disc... |
| B88069X3831B502 | EPCOS (TDK) | 0.0 $ | 1000 | ER6-A230XGas Discharge Tu... |
| B88069X5111B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
| B88069X7631B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
| B88069X6051T902 | EPCOS (TDK) | -- | 1000 | GDT 90V 20% 10KA SURFACE ... |
| B88069X6191T103 | EPCOS (TDK) | 0.36 $ | 1000 | M50-A600XGas Discharge Tu... |
| B88069X8910B502 | EPCOS (TDK) | -- | 1354 | GDT 230V 20% 10KA THROUGH... |
| B88069X0270S102 | EPCOS (TDK) | 3.72 $ | 1000 | GDT 5000V THROUGH HOLEGas... |
| B88069X3450T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 1000V THROUGH HOLEGas... |
| B88069X4600C253 | EPCOS (TDK) | 0.8 $ | 2375 | GDT 230V 20% 5KAGas Disch... |
| B88069X210S102 | EPCOS (TDK) | 2.08 $ | 394 | GDT 2000V THROUGH HOLEGas... |
| B88069X8350B502 | EPCOS (TDK) | 1.58 $ | 500 | GDT 90V 10KA T/H FAIL SHO... |
| B88069X1790C103 | EPCOS (TDK) | 0.96 $ | 448 | GDT 230V 15% 5KAGas Disch... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X8170C203 Datasheet/PDF