Allicdata Part #: | BR2C4UC-ND |
Manufacturer Part#: |
BR2C4UC |
Price: | $ 37.28 |
Product Category: | Circuit Protection |
Manufacturer: | Weidmuller |
Short Description: | CB MCB 489 2P C 4A ACDC |
More Detail: | N/A |
DataSheet: | BR2C4UC Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 33.88770 |
Series: | BRxxxUC |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal Magnetic |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 4A |
Voltage Rating - AC: | 480V |
Voltage Rating - DC: | 125V |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | None |
Illumination Voltage (Nominal): | -- |
Mounting Type: | DIN Rail |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers
Circuit breakers are an important protective device in the power distribution system. These devices are developed to protect electrical equipment from damage and excessive loads. They are also used to minimize the possibility of electrical fire hazards.
BR2C4UC is a type of circuit breaker that is used for the protection of any electrical system. This type of circuit breaker has a thermal-magnetic trip unit and a quick response Bimetallic strip. It is built with high breaking capacity and is designed to protect against short circuit and overcurrent conditions.
Application Field
BR2C4UC circuit breakers are designed to operate in low voltage systems (less than 1000 Volts AC). It is typically used in commercial, industrial and mining applications such as power plants, elevator systems, air conditioning systems and powering of large machines. It can be used to protect against short-circuit, overload and earth leakage current.
Working Principle
BR2C4UC circuit breakers are composed of a thermal-magnetic trip unit, current transformers and a bimetallic strip. The thermal-magnetic trip unit is a small device that senses the amount of current flowing through the device. The current transformer is a device which transforms the high current to a low voltage so that the trip unit can detect it. The bimetallic strip is a device which bends when subjected to high temperatures, pushing the trip unit into the circuit breaker opening in order to interrupt the electrical flow.
The thermal-magnetic trip unit has two sensing elements: one that senses the current and the other that senses the temperature. The first element allows the unit to detect any overloads, while the second element allows it to detect high temperature. When both elements detect any abnormality, the trip unit will activate, causing the bimetallic strip to bend, which opens the circuit breaker.
Conclusion
BR2C4UC circuit breakers are important protective devices that are designed to offer protection against short circuit and overcurrent conditions. The thermal-magnetic trip unit, current transformers and bimetallic strip are the main components of the device and allow it to detect any abnormality in the power system. They are primarily used in low voltage systems and can be used in commercial, industrial and mining applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
BR2C10UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 10A ACDC |
BR2C12UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 12A ACDC |
BR2C13UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 13A ACDC |
BR2C15UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 15A ACDC |
BR2C1UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 1A ACDC |
BR2C20UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 20A ACDC |
BR2C25UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 25A ACDC |
BR2C2UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 2A ACDC |
BR2C30UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 30A ACDC |
BR2C3UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 3A ACDC |
BR2C40UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 40A ACDC |
BR2C4UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 4A ACDC |
BR2C50UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 50A ACDC |
BR2C5UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 5A ACDC |
BR2C60UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 60A ACDC |
BR2C6UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 6A ACDC |
BR2C8UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 8A ACDC |
BR2C7UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 7A ACDC |
BR2C16UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 16A ACDC |
BR2C32UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 32A ACDC |
BR2C35UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 35A ACDC |
BR2C63UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P C 63A ACDC |
BR2C05AC | Weidmuller | 43.17 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C10AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C12AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C13AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C15AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C1AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C20AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C25AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C2AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C30AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C3AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2PCCTBRKR/C CURVE3 |
BR2C40AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C4AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C50AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C5AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C60AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C6AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
BR2C8AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/C CURVE... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A