| Allicdata Part #: | BR2D4UC-ND |
| Manufacturer Part#: |
BR2D4UC |
| Price: | $ 37.28 |
| Product Category: | Circuit Protection |
| Manufacturer: | Weidmuller |
| Short Description: | CB MCB 489 2P D 4A ACDC |
| More Detail: | N/A |
| DataSheet: | BR2D4UC Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1 +: | $ 33.88770 |
| Series: | BRxxxUC |
| Part Status: | Active |
| Lead Free Status / RoHS Status: | -- |
| Breaker Type: | Thermal Magnetic |
| Moisture Sensitivity Level (MSL): | -- |
| Current Rating: | 4A |
| Voltage Rating - AC: | 480V |
| Voltage Rating - DC: | 125V |
| Number of Poles: | 2 |
| Actuator Type: | Lever |
| Illumination: | None |
| Illumination Voltage (Nominal): | -- |
| Mounting Type: | DIN Rail |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are essential to the overall safety and operation of an electrical system. Most circuit breakers have a range of ratings for different loads and applications. In industrial applications, it is particularly important to have a circuit breaker that is specialized for a particular load and environment. A BR2D4UC circuit breaker, which is a term specific to North America, is a type of circuit breaker that is ideal for high current applications where frequent or automatic resetting of the breaker is desirable. This type of breaker may also be referred to by other names such as BR2 and BR4.
A BR2D4UC circuit breaker is specifically designed for heavy industrial applications such as vehicle charging stations and electric forklifts, as well as electric motors, generators, vacuum pumps and air compressors. It is rated for continuous operation at currents up to 1000A and has a reply of 1/2 second. The BR2D4UC circuit breaker also has a thermal magnetic trip unit that responds to overcurrents in order to protect against electric shock and fire hazards.
The working principle of the BR2D4UC circuit breaker is based on the fact that electricity flows in loops, and a circuit breaker essentially interrupts the flow of electricity in a particular part of the loop when it detects an overload or short circuit. In the case of the BR2D4UC , an internal thermal-magnetic trip unit is used to detect when an unsafe amount of current is flowing. When this happens, an internal contactor is opened and the current is interrupted, triggering the breaker to trip.
The BR2D4UC thermal-magnetic trip unit is equipped with adjustable long time, short time, and instantaneous trip adjusting settings. This allows the user to select the appropriate setting for the application in order to ensure the circuit breaker trips when necessary, but does not trip when the load is close to, but below the rated load. This type of circuit breaker also has a manual reset button so the user can reset the breaker when necessary.
The versatility of the BR2D4UC circuit breaker makes it an ideal choice for a wide range of applications. The thermal-magnetic trip unit helps protect against overloads and short circuits, while the adjustable settings and manual reset button give the user a level of control over their circuit breaker. By properly selecting and setting up the BR2D4UC, users can ensure the overall safety of their electrical system and get the most out of the breaker.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| BR2D25AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D8AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D1AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D05AC | Weidmuller | 38.54 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D12UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 12A ACDC |
| BR2D2UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 2A ACDC |
| BR2D6AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D20UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 20A ACDC |
| BR2D40AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D30UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 30A ACDC |
| BR2D60AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D25UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 25A ACDC |
| BR2D3AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D32UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 32A ACDC |
| BR2D5UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 5A ACDC |
| BR2D4AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D60UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 60A ACDC |
| BR2D1UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 1A ACDC |
| BR2D50AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D30AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D5AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D10AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D15UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 15A ACDC |
| BR2D20AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D40UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 40A ACDC |
| BR2D7UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 7A ACDC |
| BR2D63UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 63A ACDC |
| BR2D15AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D12AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D2AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D4UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 4A ACDC |
| BR2D35UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 35A ACDC |
| BR2D13AC | Weidmuller | 0.0 $ | 1000 | BRANCH/2P CCTBRKR/D CURVE... |
| BR2D50UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 50A ACDC |
| BR2D10UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 10A ACDC |
| BR2D6UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 6A ACDC |
| BR2D8UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 8A ACDC |
| BR2D3UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 3A ACDC |
| BR2D13UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 13A ACDC |
| BR2D16UC | Weidmuller | 37.28 $ | 1000 | CB MCB 489 2P D 16A ACDC |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A
BR2D4UC Datasheet/PDF