Allicdata Part #: | CB222-30-ND |
Manufacturer Part#: |
CB222-30 |
Price: | $ 15.04 |
Product Category: | Circuit Protection |
Manufacturer: | Eaton |
Short Description: | CIR BRKR 30A PUSH-RESET |
More Detail: | N/A |
DataSheet: | CB222-30 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
10 +: | $ 13.67980 |
Series: | CB222 |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | -- |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 30A |
Number of Poles: | 1 |
Actuator Type: | Push to Reset |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Holder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are critical components of electrical systems, providing protection in the event of an overload. CB222-30 circuit breakers are used in multiple applications and come in a variety of sizes and ratings.
One application that the CB222-30 circuit breaker is used in is distribution circuits. These circuits are used in a variety of electrical installations, such as commercial buildings, industrial settings, and residential areas. It is important to have a reliable circuit breaker to protect the circuit from overloads or short circuits. The CB222-30 is an ideal choice for distribution circuits, as it provides reliable protection with a current rating of 30 amps.
The CB222-30 circuit breaker is also used in motor control circuits. Motors are often used in industrial, commercial, and residential settings, and it is important that they are protected from overloads and short circuits. The CB222-30 provides reliable protection with a current rating of 30 amps. In addition, the CB222-30 has a thermal-magnetic trip, meaning the breaker will trip if there is an overload or an electrical fault.
The CB222-30 circuit breaker is also used in motor control circuits, such as in elevators. Elevators require reliable protection from overloads, short circuits, and ground faults, as well as other potential hazards. The CB222-30 has a current rating of 30 amps, as well as a thermal-magnetic trip, providing the necessary protection. The CB222-30 is an ideal choice for motor control circuits and elevator applications.
The working principle of the CB222-30 circuit breaker is fairly simple. The breaker is designed with a thermal element that monitors the current flowing through the circuit. If the current exceeds the rated amount, the thermal element will cause the breaker to trip and shut off the power to the circuit. This protects the circuit from overloads or short circuits.
In addition to protecting the circuit from overloads, the CB222-30 is also designed with a magnetic trip. This trip is triggered in the event of a ground fault, protecting the circuit from damaging electrical shocks and fires. The magnetic trip will also trip the breaker if the current exceeds the rating, as it works in tandem with the thermal element.
The CB222-30 circuit breaker is designed to provide reliable protection for distribution circuits, motor control circuits, and elevators. It has a current rating of 30 amps and a thermal-magnetic trip that protect against overloads, short circuits, and ground faults. The working principle of the CB222-30 is based on the thermal element, which monitors the current flow and trips the breaker if the current exceeds the rating. The magnetic trip protects against ground faults and provides an additional layer of protection for the circuit.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HLMP-CB22-SV000 | Broadcom Lim... | 0.0 $ | 1000 | LED BLUE CLEAR 5MM ROUND ... |
HLMP-CB22-SV0DD | Broadcom Lim... | 0.0 $ | 1000 | LED BLUE CLEAR 5MM ROUND ... |
CB227-05 | Eaton | 7.97 $ | 1000 | CIR BRKR 5A PUSH-RESET |
CB227-06 | Eaton | 7.97 $ | 1000 | CIR BRKR 6A PUSH-RESET |
CB227-10 | Eaton | 7.97 $ | 1000 | CIR BRKR 10A PUSH-RESET |
CB227-15 | Eaton | 7.97 $ | 1000 | CIR BRKR 15A PUSH-RESET |
CB227-20 | Eaton | 7.97 $ | 1000 | CIR BRKR 20A PUSH-RESET |
CB227-25 | Eaton | 7.97 $ | 1000 | CIR BRKR 25A PUSH-RESET |
CB227-30 | Eaton | 7.97 $ | 1000 | CIR BRKR 30A PUSH-RESET |
CB227-7-1/2 | Eaton | 7.97 $ | 1000 | CIR BRKR 7.5A PUSH-RESET |
BK/CB221-7-1/2 | Eaton | 9.76 $ | 1000 | CIR BRKR 7.5A 14V AUTOMAT... |
CB225-56-QY | Panduit Corp | 0.0 $ | 1000 | CONN TERM RECT LUG 4/0-2A... |
CB22901-1.5 | Eaton | 6.87 $ | 1000 | TVS DIODE CIRC BREAKER |
CB223-7-1/2 | Eaton | 14.95 $ | 1000 | CIR BRKR 7.5A PUSH-RESET |
CB221-10 | Eaton | 15.04 $ | 1000 | CIR BRKR 10A AUTO RESET |
CB221-15 | Eaton | 15.04 $ | 1000 | CIR BRKR 15A AUTO RESET |
CB221-20 | Eaton | 15.04 $ | 1000 | CIR BRKR 20A AUTO RESET |
CB221-25 | Eaton | 15.04 $ | 1000 | CIR BRKR 25A AUTO RESET |
CB221-30 | Eaton | 15.04 $ | 1000 | CIR BRKR 30A AUTO RESET |
CB221-7-1/2 | Eaton | 15.04 $ | 1000 | CIR BRKR 7.5A AUTO RESET |
CB222-10 | Eaton | 15.04 $ | 1000 | CIR BRKR 10A PUSH-RESET |
CB222-15 | Eaton | 15.04 $ | 1000 | CIR BRKR 15A PUSH-RESET |
CB222-20 | Eaton | 15.04 $ | 1000 | CIR BRKR 20A PUSH-RESET |
CB222-25 | Eaton | 15.04 $ | 1000 | CIR BRKR 25A PUSH-RESET |
CB222-30 | Eaton | 15.04 $ | 1000 | CIR BRKR 30A PUSH-RESET |
CB223-10 | Eaton | 16.98 $ | 1000 | CIR BRKR 10A PUSH-RESET |
CB223-15 | Eaton | 16.98 $ | 1000 | CIR BRKR 15A PUSH-RESET |
CB223-20 | Eaton | 16.98 $ | 1000 | CIR BRKR 20A PUSH-RESET |
CB223-25 | Eaton | 16.98 $ | 1000 | CIR BRKR 25A PUSH-RESET |
CB223-30 | Eaton | 16.98 $ | 1000 | CIR BRKR 30A PUSH-RESET |
CB225-56HKR-Q | Panduit Corp | 10.38 $ | 1000 | COPPER MECH LUG, 1 HOLE, ... |
BK/CB221-10 | Eaton | 9.76 $ | 1000 | CIRCUIT BREAKE |
BK/CB221-15 | Eaton | 9.76 $ | 1000 | CIRCUIT BREAKE |
BK/CB221-25 | Eaton | 9.76 $ | 1000 | CIRCUIT BREAKE |
SL12-CB220 | Omron Automa... | 8.6 $ | 1000 | BULB FOR CONDUIT LIGHT 22... |
CB2279-000 | TE Connectiv... | 0.92 $ | 1000 | 55PC CABLEConductor Cabl... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A