Allicdata Part #: | DHR1000C420-ND |
Manufacturer Part#: |
DHR 1000 C420 |
Price: | $ 161.08 |
Product Category: | Sensors, Transducers |
Manufacturer: | LEM USA Inc. |
Short Description: | SENSOR CURRENT HALL 1000A AC/DC |
More Detail: | Current Sensor 1000A 1 Channel Hall Effect, Open L... |
DataSheet: | ![]() |
Quantity: | 1000 |
24 +: | $ 146.43400 |
Frequency: | DC ~ 6kHz |
Package / Case: | Module |
Mounting Type: | Panel Mount |
Polarization: | Bidirectional |
Operating Temperature: | -40°C ~ 70°C |
Current - Supply (Max): | 30mA |
Response Time: | 150ms |
Voltage - Supply: | 20 V ~ 50 V |
Accuracy: | ±1% |
Linearity: | ±1% |
Series: | DHR |
Sensitivity: | -- |
Output: | Ratiometric, 4mA ~ 20mA |
Number of Channels: | 1 |
Current - Sensing: | 1000A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current Transducers are widely used to monitor the electric power consumption of a particular device. The DHR1000 C420 is one of these types of transducers. This current transducer offers a variety of features and benefits, making it a great choice for a variety of applications. In this article, we\'ll look at the application field and working principle of the DHR1000 C420.
Application field: The DHR1000 C420 is commonly used in industrial and commercial applications. It can be used to monitor the current in motors, pumps, transformers, lighting systems, distribution lines and other electrical devices. It is also suitable for use in photovoltaic systems, wind turbines, hydroelectric plants and other renewable energy sources.
In addition, the DHR1000 C420 can be used to measure and monitor the current in equipment used in medical, military and research facilities. Some other potential applications for the DHR1000 C420 include air conditioning systems, HVAC systems, data centers, and energy management systems.
Working Principle: The DHR1000 C420 uses an inductive type of transducer. This type of transducer uses an inductor to measure the current in a circuit. The inductor creates a magnetic field in response to current flowing through it. The strength of this magnetic field is proportional to the current flowing through the circuit. The transducer then converts the magnetic field into an electrical signal, which is then sent to a display unit or recording device.
The DHR1000 C420 offers accurate and reliable current measurement. It can measure current within a wide range from 0.5A to 100A. It also has a response time of 25 microseconds, which makes it ideal for monitoring fast-changing currents. The transducer is also highly efficient, with a power consumption of less than 0.3 Watts. Furthermore, it is designed for durability and long-term use, with an operating temperature range of -40˚C to 175˚C.
The DHR1000 C420 is an ideal choice for monitoring current in many different applications. Its accuracy, reliability, efficiency and durability make it a great choice for many commercial and industrial applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
DHR14BD1 | TE Connectiv... | 15.25 $ | 1000 | DHR14BD1 |
DHR 100 C10 | LEM USA Inc. | 160.43 $ | 64 | SENSOR CURRENT HALL 100A ... |
DHR 500 C10 | LEM USA Inc. | 143.19 $ | 1000 | SENSOR CURRENT HALL 500A ... |
DHR 500 C5 | LEM USA Inc. | 125.25 $ | 1000 | SENSOR CURRENT HALL 500A ... |
EG-2102CA 125.0000M-DHRAL3 | Epson | 6.31 $ | 1000 | OSC SO 125.000MHZ LVPECL ... |
DHR 200 C420 | LEM USA Inc. | 172.77 $ | 13 | SENSOR CURRENT HALL 200A ... |
DHR25BG | TE Connectiv... | 11.09 $ | 1000 | DHR25BG=RELAY |
DHR 300 C240 | LEM USA Inc. | 199.3 $ | 1000 | SENSOR CURRENT HALL 300A ... |
EG-2121CA 156.2500M-DHRAB | Epson | 6.31 $ | 1000 | OSC SO 156.25MHZ LVPECL S... |
DHR14B | TE Connectiv... | 8.32 $ | 1000 | DHR14B=RELAY |
DHR 1000 C5 | LEM USA Inc. | 125.25 $ | 1000 | SENSOR CURRENT HALL 1000A... |
DHR 500 C420 | LEM USA Inc. | 179.12 $ | 1000 | SENSOR CURRENT HALL 500A ... |
DHR 200 C10 | LEM USA Inc. | 125.25 $ | 1000 | SENSOR CURRENT HALL 200A ... |
EG-2121CA 106.2500M-DHRAB | Epson | 6.31 $ | 1000 | OSC SO 106.25MHZ LVPECL S... |
DHR7B | TE Connectiv... | 10.4 $ | 1000 | DHR7B=CONTACTOR - 3PDT |
DHR 200 C5 | LEM USA Inc. | 79.27 $ | 1000 | SENSOR CURRENT HALL 200A ... |
DHR 1000 C420 | LEM USA Inc. | 161.08 $ | 1000 | SENSOR CURRENT HALL 1000A... |
DHR 1000 C10 | LEM USA Inc. | 151.03 $ | 1000 | SENSOR CURRENT HALL 1000A... |
DHR7BE | TE Connectiv... | 7.62 $ | 1000 | DHR7BE (FAA/PMA)=RELAY |
EG-2121CA 156.2500M-DHRNB | Epson | 5.88 $ | 1000 | OSC SO 156.25MHZ LVPECL S... |
DHR 100 C5 | LEM USA Inc. | 125.25 $ | 1000 | SENSOR CURRENT HALL 100A ... |
EG-2121CA 125.0000M-DHRAB | Epson | 6.31 $ | 1000 | OSC SO 125MHZ LVPECL SMD1... |
DHR 100 C420 | LEM USA Inc. | 125.25 $ | 1000 | SENSOR CURRENT HALL 100A ... |
DHR-KIT-DE | Murata Elect... | 62.55 $ | 7 | CAP KIT CER 100PF-1000PF ... |
DHR181 | TE Connectiv... | 9.7 $ | 1000 | DHR181 (FAA/PMA)=RELAY |
EG-2102CA 100.0000M-DHRAB | Epson | 6.31 $ | 1000 | OSC SO 100MHZ LVPECL SMD1... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...

SENSOR CURRENT XFMR 5A ACCurrent Sensor ...

SENSOR CURRENT HALL 15A AC/DCCurrent Sen...

3 PIECE KIT SENSOR CURRENT HALLCurrent S...

PACT RCP-4000A-1A-D190Current Sensor 100...

SENSOR CURRENT HALL 30A DCCurrent Sensor...