Allicdata Part #: | E52-CA20AD=3.28M-ND |
Manufacturer Part#: |
E52-CA20A D=3.2 8M |
Price: | $ 113.32 |
Product Category: | Sensors, Transducers |
Manufacturer: | Omron Automation and Safety |
Short Description: | RTD TEMPERATURE SENSOR |
More Detail: | K - Type Temperature Sensor 0 ~ 1050°C Non-Ground... |
DataSheet: | ![]() |
Quantity: | 1000 |
1 +: | $ 103.02400 |
Series: | E52 |
Part Status: | Active |
Element Type: | K - Type |
Temperature Range: | 0 ~ 1050°C |
Length - Lead Wire: | 26.247' (8m) |
Conductor Type: | Non-Grounded |
Terminal Type: | Exposed Lead Wires |
Length - Protective Tube: | 1.1m |
Diameter - Protective Tube: | 3.2mm |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
E52-CA20A D=3.2 8M is a temperature sensor - thermocouple and temperature probe from Omron. As a temperature measurement device, it is especially suitable for measuring the temperature of metals.--especially metals with high temperatures. It is widely used in industrial application fields, such as metal processing, steel making, glass making, and chemical industry.
The operating principle of E52-CA20A D=3.2 8M can be described as follows: First, two dissimilar metals, which are joined together, form a thermocouple. This thermocouple typically consists of an external cable that connects to the initial reference thermocouple and a measuring module. The measuring module is then connected to an instrument such as a thermometer that can measure the temperature difference across the thermocouple.
When a temperature difference occurs across the junctions of the two metals, an electromotive force (EMF) is generated. This EMF can be measured, and is proportional to the temperature difference. The EMF generated by the thermocouple can be measured and detected by a measuring instrument. This proves to be the most accurate and reliable way to measure temperature.
The E52-CA20A D=3.2 8M is the perfect choice of temperature measurement device for harsh industrial application fields. It can measure temperatures up to an accuracy of 0.5°C. The thermocouple probe is a robust device and can be used in temperatures from -170°C to +1250°C. It is designed for fast response times of 10ms, and can be used in dusty or wet enviroments.
To maintain the accuracy of the device, the thermocouple needs to be regularly calibrated. It is important to use a calibration source that covers the entire temperature range that the thermocouple measures. The device should also be regularly examined for any signs of damage as this can cause inaccurate measurements. This temperature sensor is relatively simple to use and can be easily integrated into existing system.
In conclusion, the E52-CA20A D=3.2 8M is a reliable and robust temperature sensor. It is perfect for use in harsh industrial application fields where accuracy and fast response times are vital. It has a wide temperature range and can be easily integrated into existing systems. Regular maintenance and calibration is important to maintain accuracy.
The specific data is subject to PDF, and the above content is for reference
THERMOCOUPLEK - Type Temperature Sensor ...