HASS 200-S Sensors, Transducers |
|
Allicdata Part #: | 398-1064-ND |
Manufacturer Part#: |
HASS 200-S |
Price: | $ 15.79 |
Product Category: | Sensors, Transducers |
Manufacturer: | LEM USA Inc. |
Short Description: | SENSOR CURRENT HALL 200A AC/DC |
More Detail: | Current Sensor 200A 1 Channel Hall Effect, Open Lo... |
DataSheet: | ![]() |
Quantity: | 1668 |
1 +: | $ 14.34510 |
5 +: | $ 13.69490 |
10 +: | $ 12.39080 |
25 +: | $ 11.41280 |
50 +: | $ 10.10850 |
100 +: | $ 9.78243 |
500 +: | $ 9.13031 |
Frequency: | DC ~ 50kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -40°C ~ 85°C |
Current - Supply (Max): | 19mA |
Response Time: | 3µs |
Voltage - Supply: | 5V |
Accuracy: | ±1% |
Linearity: | ±0.5% |
Series: | HASS |
Sensitivity: | -- |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 200A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Tray |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are an important family of electrical sensors that measure and transform current such as electrical power, telecommunication, or industrial process control into another useful form of energy such as electrical signal, light signal, or some other type of information such as temperature. They are typically used in industrial, residential and commercial applications. In industrial applications, current transducers are used to collect and monitor power consumption, monitor and control power failure and to improve transmission and communication systems. In commercial applications, they are used to monitor power quality, detect transient current and electrical problem, or used to provide data for security systems and industrial automation.
HASS 200-S is a type of current transducer that is widely used for industrial, residential and commercial applications. This current transducer has a wide measurement range of up to 3600A, allowing it to be used in various applications ranging from automobile parts monitoring to power switchgear control. It has a measuring accuracy of ± 0.5% and a wide input voltage range of 15-480V. The HASS 200-S is also equipped with an isolated output which helps to protect the device and surrounding electrical components from damage due to induced interference.
The working principle of the HASS 200-S current transducer is based on the principle of mutual induction. This means that when a current is passed through the primary winding of the transducer, a voltage is induced in the secondary winding, which is then measured and utilized to compute the electrical power or energy consumed. The current transducer utilizes two “coils”: the primary and secondary. These coils are then connected through a permanent magnet. The current passing through the primary coil induces a magnetic field in the primary coil, which in turn induces a voltage in the secondary coil. This voltage is then measured and used to compute the amount of energy consumed. Additionally, the HASS 200-S current transducer has a built-in power calibration and supervision feature, which can easily detect and identify possible problems in the system before they can cause any damage.
The application of HASS 200-S current transducers is primarily in the industrial, residential and commercial sectors. In the industrial sector, these current transducers can be used to measure and monitor power consumption, to detect transient currents and electrical problems, or to provide data for security systems and industrial automation. In the residential sector, these devices help provide accurate readings of electricity and gas meters which are used to calculate bills. In the commercial sector, these devices are used to detect electrical problems such as power surges and voltage drops. Additionally, they can also be used to measure the power quality of electric systems, thereby assessing potential risks and weak points in the system.
The HASS 200-S current transducer is a reliable and accurate device for industrial, residential and commercial applications. Its wide range of measurement and high accuracy makes it suitable for a variety of applications and ensures that it consistently delivers accurate results. The built-in safety feature of the device helps to protect the device and surrounding components from any possible harm due to current or voltage fluctuations. Its easy installation and low supervision cost makes it a preferred choice for many commercial and industrial applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
HASS 100-S | LEM USA Inc. | 15.79 $ | 982 | SENSOR CURRENT HALL 100A ... |
HASS 500-S | LEM USA Inc. | 17.65 $ | 825 | SENSOR CURRENT HALL 500A ... |
HASS 600-S | LEM USA Inc. | 16.7 $ | 103 | SENSOR CURRENT HALL 600A ... |
HASS 300-S | LEM USA Inc. | 16.7 $ | 328 | SENSOR CURRENT HALL 300A ... |
HASS 50-S | LEM USA Inc. | 15.79 $ | 625 | SENSOR CURRENT HALL 50A A... |
HASS 200-S | LEM USA Inc. | 15.79 $ | 1668 | SENSOR CURRENT HALL 200A ... |
HASS 400-S | LEM USA Inc. | 16.7 $ | 387 | SENSOR CURRENT HALL 400A ... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...

SENSOR CURRENT XFMR 5A ACCurrent Sensor ...

SENSOR CURRENT HALL 15A AC/DCCurrent Sen...

3 PIECE KIT SENSOR CURRENT HALLCurrent S...

PACT RCP-4000A-1A-D190Current Sensor 100...

SENSOR CURRENT HALL 30A DCCurrent Sensor...