IULN0-0 Circuit Protection |
|
Allicdata Part #: | IULN0-0-ND |
Manufacturer Part#: |
IULN0-0 |
Price: | $ 65.49 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | IULN0-0 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
3 +: | $ 59.53500 |
Series: | * |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Moisture Sensitivity Level (MSL): | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
The IULN0-0 circuit breaker is an excellent electrical protective device used in industrial operations. It is designed to open or close an electrical circuit based on an electrical fault event. When an overload current or short circuit event occurs, the IULN0-0 will quickly break the circuit to prevent further damage to the electrical equipment and components. The IULN0-0 circuit breaker can handle excessive and momentary overloads and short circuit events, as well as other abnormal overcurrent situations due to electrical faults. Along with its fast-acting trip and reset capabilities, the IULN0-0 is ideal for protecting sensitive equipment from overcurrent events.
The IULN0-0 circuit breaker is commonly found in many industrial applications. It is used for electrical protection in manufacturing plants, commercial/industrial buildings, power distribution systems, and other specialized industrial systems. Its main purpose is to provide dependable protection against short circuits, overloads, and other overcurrent events that can occur in large electrical systems. It is also used in motor control and air conditioning systems to protect against overcurrent, short circuit, and motor stalling conditions. Other applications include protection of outdoor power lines, battery chargers, and power sources in hazardous locations.
The IULN0-0 circuit breaker is designed to operate in a variety of environments. It is suitable for both indoor and outdoor applications that require protection against overcurrent and short circuit conditions. It is designed to be reliable, efficient, and safe while operating in hazardous and high voltage environments. As it has a long life expectancy, it is also suitable for use in remote locations that require long-term protection of equipment.
The IULN0-0 circuit breaker does not require complicated setup and installation. It is typically mounted on a DIN rail or an appropriate mounting bracket for easy installation and connection. It is also well suited for retrofit applications in which existing devices need to be replaced or upgraded. The IULN0-0 is equipped with a three-pole construction, multiple contact points, and a wide variety of tripping characteristics, allowing it to be tailored to a wide range of applications. The IULN0-0 is a time-current device, meaning that it will trip in response to changing current load.
The IULN0-0 circuit breaker’s working principle is simple. It utilizes a thermal-magnetic mechanism to detect an overcurrent event or short circuit condition. The breaker has an overloaded thermal element, which trips in response to a sustained or momentary overcurrent situation. At the same time, it also has a magnetic element, which trips in response to an instantaneous current level. If either of the elements detects an overcurrent condition, the breaker trips, opening the circuit and preventing further damage to the electrical components.
The IULN0-0 circuit breaker is a great electrical protective device that is perfect for many industrial applications. Its fast-acting trip and reset capabilities, reliable construction, and wide range of tripping characteristics make it ideal for protecting equipment from electrical faults. Its thermal-magnetic mechanism provides safe and dependable protection against short circuits, overloads, and other overcurrent events. When properly installed and maintained, the IULN0-0 is an efficient and reliable electrical protective device that can be used safely in hazardous and high voltage environments.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
IULNK0-33763-1 | Sensata-Airp... | 49.35 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-40 | Sensata-Airp... | 49.84 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-50 | Sensata-Airp... | 49.84 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-36337-15 | Sensata-Airp... | 50.12 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-1 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-2 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-3 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-31269-14 | Sensata-Airp... | 51.48 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-31269-4 | Sensata-Airp... | 51.48 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38904-70 | Sensata-Airp... | 63.35 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-4 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-60 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-70 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-80 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK2-35605-1 | Sensata-Airp... | 65.2 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULNK2-35605-4 | Sensata-Airp... | 65.2 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULN0-0 | Sensata-Airp... | 65.49 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK2-34355-2 | Sensata-Airp... | 65.91 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULN11-37173-1 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32920-2 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-35323-100 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-1REC4-40592-2 | Sensata-Airp... | 82.62 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULN1-1-53-70.0 | Sensata-Airp... | 82.97 $ | 1000 | CIR BRKR MAG-HYDR 70A TOG... |
IULNK1-1REC5-52-7.50 | Sensata-Airp... | 83.26 $ | 1000 | CIR BRKR MAG-HYDR |
IULN2-39986-60 | Sensata-Airp... | 83.76 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULN1-1REC4-71F-7.50 | Sensata-Airp... | 84.4 $ | 1000 | CIR BRKR MAG-HYDR 7.5A TO... |
IULNK1-40522-70 | Sensata-Airp... | 84.97 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-1REC4-52-.500 | Sensata-Airp... | 85.53 $ | 1000 | CIR BRKR MAG-HYDR |
IULNK1-1-51-100. | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-51-100.-A | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-51-60.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 60A TOG... |
IULNK1-1-51-70.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 70A TOG... |
IULNK1-1-51-80.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-51-80.0-A | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-52-100. | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-52-60.0-K | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 60A TOG... |
IULNK1-1-52-65.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 65A TOG... |
IULNK1-1-52-75.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 75A TOG... |
IULNK1-1-52-80.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-52-90.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 90A TOG... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A