IULNPK11-36743-1 Circuit Protection |
|
Allicdata Part #: | IULNPK11-36743-1-ND |
Manufacturer Part#: |
IULNPK11-36743-1 |
Price: | $ 229.10 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIR BRKR MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | IULNPK11-36743-1 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
3 +: | $ 208.26300 |
Series: | IUL |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers are indispensable components of electrical systems that protect wiring and other components from overloads and short circuits. The IULNPK11-36743-1 is a two-pole circuit breaker featuring a common trip circuit breaker, which is especially useful when multiple breakers are wired in a two-pole set. It is designed for both AC and DC applications in the 10-40 Amp range.
The IULNPK11-36743-1 circuit breaker can be necessary in industrial settings where high-power currents are necessary for machines to operate. It is a breaker that is designed to trip when the current load exceeds its safe operational threshold. This helps to protect other devices, wiring, and circuits from electrical overloads and short circuits. In industrial settings, circuit breakers often include a manual reset option which provides an extra layer of protection against malfunctions. It is also a breaker that can be used to provide electrical power to the machines.
The working principle of the IULNPK11-36743-1 circuit breaker is based on the heat generated by the current passing through the breaker. The heat passes through a thermal element, which is triggered to open the contacts of the breaker. This action causes the current to be interrupted, or ‘tripped’, thus protecting the wiring and other components. It is important to note that the IULNPK11-36743-1 circuit breaker must be properly sized for the amount of current it is designed to interrupt.
In addition to its industrial application, the IULNPK11-36743-1 circuit breaker can also be used in residential settings as a form of protection against electrical overloads. Residential circuit breakers may typically have a lower rating than that of industrial use, but they are nonetheless effective in providing an extra layer of protection to the system. The IULNPK11-36743-1 circuit breaker can also be used to provide metering and isolation protection in commercial settings where current measurements are necessary.
In conclusion, the IULNPK11-36743-1 circuit breaker is a versatile component that can be used in a wide variety of applications. Its ability to protect wiring and other components from overload and short circuits makes it an invaluable tool in both industrial and residential settings. Its working principle is based on the heat generated by the flow of current, which triggers the breaker to interrupt the current and protect the system from further damage. The IULNPK11-36743-1 Circuit Breaker is thus an essential component in an electrical system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
IULNK0-33763-1 | Sensata-Airp... | 49.35 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-40 | Sensata-Airp... | 49.84 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-50 | Sensata-Airp... | 49.84 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-36337-15 | Sensata-Airp... | 50.12 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-1 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-2 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38279-3 | Sensata-Airp... | 51.34 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-31269-14 | Sensata-Airp... | 51.48 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-31269-4 | Sensata-Airp... | 51.48 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-38904-70 | Sensata-Airp... | 63.35 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-4 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-60 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-70 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32388-80 | Sensata-Airp... | 63.71 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK2-35605-1 | Sensata-Airp... | 65.2 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULNK2-35605-4 | Sensata-Airp... | 65.2 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULN0-0 | Sensata-Airp... | 65.49 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK2-34355-2 | Sensata-Airp... | 65.91 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
IULN11-37173-1 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-32920-2 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-35323-100 | Sensata-Airp... | 66.63 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-1REC4-40592-2 | Sensata-Airp... | 82.62 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULN1-1-53-70.0 | Sensata-Airp... | 82.97 $ | 1000 | CIR BRKR MAG-HYDR 70A TOG... |
IULNK1-1REC5-52-7.50 | Sensata-Airp... | 83.26 $ | 1000 | CIR BRKR MAG-HYDR |
IULN2-39986-60 | Sensata-Airp... | 83.76 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULN1-1REC4-71F-7.50 | Sensata-Airp... | 84.4 $ | 1000 | CIR BRKR MAG-HYDR 7.5A TO... |
IULNK1-40522-70 | Sensata-Airp... | 84.97 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULNK1-1REC4-52-.500 | Sensata-Airp... | 85.53 $ | 1000 | CIR BRKR MAG-HYDR |
IULNK1-1-51-100. | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-51-100.-A | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-51-60.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 60A TOG... |
IULNK1-1-51-70.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 70A TOG... |
IULNK1-1-51-80.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-51-80.0-A | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-52-100. | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 100A TO... |
IULNK1-1-52-60.0-K | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 60A TOG... |
IULNK1-1-52-65.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 65A TOG... |
IULNK1-1-52-75.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 75A TOG... |
IULNK1-1-52-80.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 80A TOG... |
IULNK1-1-52-90.0 | Sensata-Airp... | 85.75 $ | 1000 | CIR BRKR MAG-HYDR 90A TOG... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A