UPGH11-8355-1 Circuit Protection |
|
Allicdata Part #: | UPGH11-8355-1-ND |
Manufacturer Part#: |
UPGH11-8355-1 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | UPGH11-8355-1 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | UPG |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit Breakers: UPGH11-8355-1 Application Field and Working Principle
Circuit breakers have been used for a very long time in order to protect sensitive electrical components and equipment from dangerous levels of electricity. With the introduction of the UPGH11-8355-1 circuit breaker, these same protection abilities are now available at a much lower cost than traditional breakers. This makes the UPGH11-8355-1 a great choice for both home and industrial applications.
The UPGH11-8355-1 circuit breaker features both manual and automatic trip feature capabilities. This means that it can be used in a variety of situations. For example, it can be used to protect general-purpose circuits as well as industrial equipment. Additionally, it can be adjusted to trip at a specific current level. This ensures that it provides the necessary level of protection, even with extreme levels of current.
The UPGH11-8355-1 circuit breaker also features a built-in override system that allows it to operate even in the event of an overload or short-circuit condition. This makes it a great choice for applications that require a circuit breaker that is able to withstand high levels of current and is able to trip without causing further damage to the circuit or surrounding equipment.
The working principle of the UPGH11-8355-1 circuit breaker is quite simple. It work using a bimetal strip that contracts or expands depending on the amount of current flowing through it. This bimetal strip is connected to two contacts which act as the connections for the two terminals of the circuit breaker. When a certain amount of current is reached, the bimetal strip expands, pushing the contacts apart and thus breaking the circuit.
Additionally, the UPGH11-8355-1 circuit breaker features a built-in temperature sensor that is designed to detect when the temperature of the circuit exceeds a predetermined level. The temperature sensor will then send a signal to the trip mechanism, and this in turn will cause the circuit breaker to trip and de-energize the circuit. This prevents the circuit from becoming overloaded and potentially damaging sensitive components or equipment.
The UPGH11-8355-1 circuit breaker is a great choice for both home and industrial applications. With its built-in overload and short-circuit protection, as well as its adjustable trip mechanism, it provides reliable and cost-effective protection for both general-purpose and industrial circuits. It is also easy to install and maintain, which further adds to its appeal.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
UPGHX11-3246-1 | Sensata-Airp... | 98.83 $ | 998 | CIR BRKR 28A 277VAC 80VDC |
UPGH04-1REC2-23806-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH04-1REC2-9589-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH04-9528-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH1111-4389-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH1111-9338-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-11-632 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-16 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-17 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-19 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-21 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-22 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-24 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-25 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-27 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-28 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-29 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-30 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-31 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-32 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-1928-91 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-9 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-20225-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-2919-11 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-3REC2-2919-33 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-3REC2-2919-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-1REC2-7944-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH112-20924-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-22161-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-2397-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A