UPGH666-2274-4 Circuit Protection |
|
Allicdata Part #: | UPGH666-2274-4-ND |
Manufacturer Part#: |
UPGH666-2274-4 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CIRCUIT BREAKER MAG-HYDR LEVER |
More Detail: | N/A |
DataSheet: | UPGH666-2274-4 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | UPG |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Magnetic (Hydraulic Delay) |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | -- |
Number of Poles: | 3 |
Actuator Type: | Lever |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Panel Mount |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers, in essence, are protective devices for electrical systems. They are designed to detect faults in a circuit and open the circuit to prevent further damage and interruption of power. The UPGH666-2274-4 is one such circuit breaker device. This article will discuss the application field and working principle of the UPGH666-2274-4.
The UPGH666-2274-4 is a circuit breaker with a small size and high sensitivity rating. It is designed for low-voltage protection requirements. This makes it suitable for a variety of applications including lighting, air conditioning, alarm systems, security systems, and motor control. The UPGH666-2274-4 is also suitable for signal transmission lines and IT/telecommunication systems. The device has a voltage rating of up to 1000V and a short-circuit-performance rating of up to 6kA.
The UPGH666-2274-4 circuit breaker consists of two parts: the contact system and the tripping mechanism. The contact system is designed to ensure the circuit can be opened and closed in a safe manner. The contacts have a silver-plated surface to improve their electrical conductivity. The tripping mechanism is responsible for detecting faults and automatically opening the circuit to prevent further damage. The tripping mechanism is designed so that it can accurately detect faults very quickly and automatically trip the circuit breaker. It also uses a bimetal disc that can sense temperature changes in the circuit.
The working principle of the UPGH666-2274-4 is very simple. The device operates by using a bimetal disc that is connected to the tripping mechanism. When the temperature of the circuit increases, the disc bends and triggers the tripping mechanism. This causes the contacts to open, thus interrupting the circuit and preventing further damage.
The UPGH666-2274-4 is a versatile and reliable circuit breaker. It is suitable for a variety of applications where low-voltage protection is required. It is designed with a sensitive tripping mechanism, which can accurately detect faults very quickly and automatically trip the circuit breaker if necessary. This ensures that any faults that occur in a circuit will be handled quickly and effectively.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
UPGHX11-3246-1 | Sensata-Airp... | 98.83 $ | 998 | CIR BRKR 28A 277VAC 80VDC |
UPGH04-1REC2-23806-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH04-1REC2-9589-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH04-9528-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH1111-4389-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH1111-9338-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-11-632 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-15 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-16 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-17 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-19 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-20 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-21 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-22 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-24 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-25 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-27 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-28 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-29 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-30 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-31 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-32 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC2-2919-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-1928-91 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-4 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-5 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-1REC4-2630-9 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-20225-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-2919-11 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-3REC2-2919-33 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH111-3REC2-2919-6 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-1REC2-7944-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH112-20924-1 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-22161-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
UPGH11-2397-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A