Allicdata Part #: | 734-1170-ND |
Manufacturer Part#: |
P51-05-G-UC-I36-4.5V-000-000 |
Price: | $ 110.80 |
Product Category: | Sensors, Transducers |
Manufacturer: | SSI Technologies Inc |
Short Description: | SENS 5PSIG 0.5-4.5 V 1/4-18 NPT |
More Detail: | Pressure Sensor 5 PSI (34.47 kPa) Vented Gauge Mal... |
DataSheet: | P51-05-G-UC-I36-4.5V-000-000 Datasheet/PDF |
Quantity: | 46 |
1 +: | $ 100.72400 |
5 +: | $ 89.53070 |
10 +: | $ 83.93490 |
25 +: | $ 81.13700 |
50 +: | $ 78.33910 |
Specifications
Series: | MediaSensor™ |
Part Status: | Active |
Pressure Type: | Vented Gauge |
Operating Pressure: | 5 PSI (34.47 kPa) |
Output Type: | Analog Voltage |
Output: | 0.5 V ~ 4.5 V |
Accuracy: | ±2% |
Voltage - Supply: | 5V |
Port Size: | Male - 1/4" (6.35mm) NPT |
Port Style: | Threaded |
Features: | Amplified Output, Temperature Compensated |
Termination Style: | Cable 3' |
Maximum Pressure: | -- |
Operating Temperature: | -40°C ~ 105°C |
Package / Case: | Cylinder |
Supplier Device Package: | -- |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Pressure Sensors, Transducers
Pressure sensors and transducers provide a highly precise way of measuring and monitoring pressure. From industrial production processes to medical diagnostics, these devices serve a wide range of applications. P51-05-G-UC-I36-4.5V-000-000 is an example of a pressure sensor and transducer.In order to understand the application field and working principle of pressure sensors and transducers such as P51-05-G-UC-I36-4.5V-000-000, it is important to first gain an understanding of the primary types of pressure sensors and transducers used in various applications. These include: absolute pressure transducers, gauge pressure transducers, differential pressure transducers,manometer transducers, and air pressure transducersAbsolute pressure transducers measure relative to atmospheric pressure, so a reading at sea level would always show +1 bar. Absolute pressure transducers generate an electrical output which is proportional to the difference in pressure, relative to atmosphere. Gauge pressure transducers measure relative to ambient pressure. This means that if atmospheric pressure is zero then a reading of +1 bar represents a pressure of +1 bar relative to atmospheric pressure.Differential pressure transducers are used to measure the difference between two absolute pressures or between two gauge pressure. This device is used to measure the pressure of a process gas pressurised pipe at two points, for example, the inlet and outlet of a turgo turbine, to measure flow. It is also used to measure gas through a filter, to calculate gas quantity, or to monitor liquid level in tanks. Manometer transducers measure the vertical height of a liquid column in a sealed container or pipe, to convert pressure units.Air pressure transducers measure air pressure in air ducts, fan or other equipment, to ensure proper air flow and ventilation. These sensors use capacitive sensing and temperature compensation to ensure accurate readings over a wide range of temperatures.P51-05-G-UC-I36-4.5V-000-000 is an example of a differential pressure transducer based on a silicon capacitive sensing element. This type of transducer couples a stainless steel pressure diaphragm with a thin film membrane capacitor. When pressure is applied to the membrane, its capacitance changes in proportion to the pressure. The membrane is electrically connected to an impedance matching circuit, which amplifies and converts the signal into a linear output. This transducer is ideal for use in 16-bit systems with a low-pressure range of 0 to 10mbar, making it suitable for a range of applications.In applications such as process gas pressurised pipes, differential pressure transducers can be used to maintain the correct pressure at the output and also to monitor the flow rate. By measuring both the pressure and the flow rate, it is possible to control the rate of flow and the pressure levels for optimum performance. In air flow monitoring applications, air pressure transducers can be used to measure the pressure in air ducts, fans, and other equipment in order to ensure the correct air flow and ventilation.P51-05-G-UC-I36-4.5V-000-000 is an example of a pressure sensor and transducer suitable for a wide range of applications. Its use of a stainless steel diaphragm combined with a thin film membrane capacitor enables it to accurately measure and monitor pressure levels and flow rates in process gas pressurised pipes, air ducts, and other equipment. In conclusion, pressure sensors and transducers are a highly precise and reliable way of measuring and monitoring pressure for a variety of applications.
The specific data is subject to PDF, and the above content is for reference
Latest Products
9781101
SST PRESSURE TRANSDUCERPressure Sensor
IPSU-G1003-5
PRSSR TRNS 0-100BR 4-20MA DINPressure Se...
SSCSLNT001BD3A3
BRD MNT PRESSURE SENSORSPressure Sensor ...
SSCMRRN005NDAA5
BRD MNT PRESSURE SENSORSPressure Sensor ...
PX2EG1XX040BSCHX
HEAVY DUTY PRESSURE TRANSDUCERPressure S...
NBPMANS100MGUNV
BRD MNT PRESSURE SENSORSPressure Sensor ...