Allicdata Part #: | 0UCB010.XP-ND |
Manufacturer Part#: |
0UCB010.XP |
Price: | $ 6.71 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | CIR BRKR 10A 12VDC AUTO RESET |
More Detail: | N/A |
DataSheet: | 0UCB010.XP Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
5 +: | $ 6.10596 |
Series: | UCB |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | -- |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 10A |
Voltage Rating - DC: | 12V |
Number of Poles: | 1 |
Actuator Type: | Automatic Reset |
Illumination: | -- |
Illumination Voltage (Nominal): | -- |
Mounting Type: | Holder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
A circuit breaker is a device that is designed to protect electrical circuits from damage caused by excess current from an overload or short circuit. The 0UCB010.XP circuit breaker is one such device and it has a unique set of features that make it highly versatile, reliable and cost effective. The 0UCB010.XP is a non-fused, overcurrent protection device and is used to protect and control large electrical circuit loads in commercial, industrial, and institutional applications. It is designed to function quickly, accurately, and reliably and is able to reset itself after a short circuit occurs.
The 0UCB010.XP has a broad range of applications and can be used for a variety of different circuit protection needs. This includes thermal magnetic protection of emergency services power supplies, non-directional overload protection of heavy industrial applications, digital overload protection of commercial and institutional applications, and directionally sensitive overload protection of UPS systems. In addition, it can also be used as a main disconnect switch in various applications. The 0UCB010.XP can also be used in Automatic Transfer Switch (ATS) applications and is approved worldwide.
The 0UCB010.XP provides the highest level of safety and reliability, and its features include trip-free operation, advanced current-limiting capability, adjustable trip settings, and a high temperature rating. It also has excellent ambient temperature characteristics and is able to withstand extreme external temperatures. Additionally, it has a high current rating and can be used in applications up to 600A.
The 0UCB010.XP employs a thermal-magnetic technology, which is an integrated protection system that combines both a thermal and magnetic trip unit. The thermal trip unit has two primary functions; one is to detect overloads from sustained currents and the other is to detect short circuits from momentary overloads. The magnetic trip unit works in tandem with the thermal trip unit and is designed to detect overloads from starting motors and other heavily inductive current inrush faults. An overload is signaled when a certain point is reached and the breaker trip closes the circuit and shuts off the power.
To further enhance protection, the 0UCB010.XP has a built-in advanced current-limiting capability which helps to reduce the current to a normal level before the trip occurs. This means that the breaker can react faster than a conventional breaker and can also reduce the risk of damage to connected equipment. It also has adjustable trip settings that allow for specific overcurrent ratings to be set caters for different applications. The 0UCB010.XP has a very fast response time and can react rapidly to changes in current, enabling it to respond quickly and efficiently to various conditions.
Overall, the 0UCB010.XP is a highly reliable and cost effective circuit breaker that can be used in a variety of applications. Its advanced features make it suitable for a wide range of different applications, including thermal magnetic protection of emergency services power supplies, non-directional overload protection of heavy industrial applications, and digital overload protection of commercial and institutional applications. The 0UCB010.XP also has a high current rating and adjustable trip settings to cater for different situations.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
0UCB005.XP | Littelfuse I... | 5.43 $ | 1000 | CIR BRKR 5A 12VDC AUTO RE... |
0UCB020.XP | Littelfuse I... | 6.01 $ | 1000 | CIR BRKR 20A 12VDC AUTO R... |
0UCB005.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 5A 12VDC AUTO RE... |
0UCB020.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 20A 12VDC AUTO R... |
0UCB030.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 30A 12VDC AUTO R... |
0UCB025.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 25A 12VDC AUTO R... |
0UCB010.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 10A 12VDC AUTO R... |
0UCB015.X | Littelfuse I... | 6.59 $ | 1000 | CIR BRKR 15A 12VDC AUTO R... |
0UCB010.XP | Littelfuse I... | 6.71 $ | 1000 | CIR BRKR 10A 12VDC AUTO R... |
0UCB030.XP | Littelfuse I... | 7.06 $ | 1000 | CIR BRKR 30A 12VDC AUTO R... |
0UCB025.XP | Littelfuse I... | 7.06 $ | 1000 | CIR BRKR 25A 12VDC AUTO R... |
0UCB015.XP | Littelfuse I... | 7.06 $ | 1000 | CIR BRKR 15A 12VDC AUTO R... |
0UCB006.XP | Littelfuse I... | 0.0 $ | 1000 | CIR BRKR 6A 12VDC AUTO RE... |
0UCB008.XP | Littelfuse I... | 0.0 $ | 1000 | CIR BRKR 8A 12VDC AUTO RE... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A