Allicdata Part #: | 2035-40-SM-ND |
Manufacturer Part#: |
2035-40-SM |
Price: | $ 0.32 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GDT 400V 15% 5KA SURFACE MOUNT |
More Detail: | Gas Discharge Tube 400V 5000A (5kA) ±15% 2 Pole Su... |
DataSheet: | 2035-40-SM Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.28319 |
Series: | 2035-SM |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 400V |
Impulse Discharge Current (8/20µs): | 5000A (5kA) |
Tolerance: | ±15% |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Surface Mount |
Package / Case: | 2-SMD Cylinder Square End |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
The principle behind Gas Discharge Tube Arresters (GDT) is that of a relationship between electrical discharge and the presence of a combustible gas environment. These devices have been in use since the early 20th century, but have seen a surge in popularity in recent years due to their efficiency, longevity and reliability.
GDTs work by taking advantage of a property known as Joule heating. Joule heating is the process by which electrical power is converted into thermal energy. GDTs utilize this process to prevent an overload of electrical energy from damaging a circuit. When an electrical current exceeds a certain threshold (known as the switching current), a spark will discharge from the GDT and cause an electrical arc. The electrical arc disrupts the path of the electrical current, causing it to disperse and prevent further damage to a circuit.
GDTs are used in many different kinds of electronic systems, including the infrastructures of telecommunications, computers, data centers and industrial automation. GDTs are also particularly effective at protecting electrical equipment from spikes caused by lightning or other sources of excessive current.
One of the more popular uses of GDTs in recent years has been in the field of motor control. In this application, GDTs can be used to protect motors by providing a resistor which can absorb unwanted spikes or drops in voltage. GDTs can be configured to provide either positive or negative voltage protection; and they are also easily adjustable to the exact specifications of any given motor.
Another important application of GDTs is in electrical surge protection. There are many different types of electrical surges, such as static electricity, line switching, electric arcs, and lightning strikes. GDTs are designed to absorb the surge before it has a chance to damage electrical equipment. The GDT can be configured to either sample the incoming voltage and open the circuit in order to dissipate the surge, or create an arc at the end point of the surge in order to dissipate it safely.
In the years leading up to 2035, GDTs had become increasingly important in the field of information technology due to the massive increases in computing power and the convergence of communication networks. GDTs are also becoming a popular choice for in-building applications, with local businesses and residences utilizing their ability to regulate power usage and reduce the impact of power surges.
In the years since 2040, GDTs have become an integral part of many complex applications. With the continued advancement of semiconductors and microcontrollers, GDTs are often found in applications such as automotive, aerospace, medical and industrial settings. GDTs are also becoming increasingly important as a tool for protecting electronics from unintended higher than normal voltage levels.
In short, Gas Discharge Tube Arresters (GDT) are used in a variety of applications and have become invaluable tools to protect a wide variety of electronic equipment. With their ability to absorb electrical surges, regulate power usage, and provide protection from overloads, GDTs are a critical component of many modern electronic systems.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
XF2L-2035-1A | Omron Electr... | 0.0 $ | 1000 | CONN FPC BOTTOM 20POS 0.5... |
PT-2035FPQ | Mallory Sona... | 1.78 $ | 13 | AUDIO PIEZO XDCR 3-28V CH... |
PT-2035FPLQ | Mallory Sona... | 1.73 $ | 1000 | AUDIO PIEZO TRANSDUCER 3-... |
2035.0 | On Shore Tec... | 0.39 $ | 1000 | MARKING TAG BLANK 6MM STR... |
2035-2 | Pomona Elect... | 5.54 $ | 183 | PLUG MINI DOUBLE BANANA R... |
SP-2035 | Soberton Inc... | 2.56 $ | 572 | SPEAKER 8OHM 1W TOP PORT ... |
203540-1 | TE Connectiv... | 18.05 $ | 27 | CONN GROUNDING BLOCK 14 P... |
203535-2 | TE Connectiv... | 7.69 $ | 18 | CONN MALE JACKSCREW |
XF2L-2035-1 | Omron Electr... | 0.0 $ | 1000 | CONN FPC BOTTOM 20POS 0.5... |
2035-09-C | Bourns Inc. | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
2035-09-C5 | Bourns Inc. | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
2035-15-C | Bourns Inc. | 0.0 $ | 1000 | GDT 150V 15% 5KA THROUGH ... |
2035-20-C | Bourns Inc. | 0.0 $ | 1000 | GDT 200V 15% 5KA THROUGH ... |
2035-23-C | Bourns Inc. | 0.0 $ | 1000 | GDT 230V 15% 5KA THROUGH ... |
2035-35-C | Bourns Inc. | 0.0 $ | 1000 | GDT 350V 15% 5KA THROUGH ... |
2035-42-C | Bourns Inc. | 0.0 $ | 1000 | GDT 420V 15% 5KA THROUGH ... |
2035-60-C5 | Bourns Inc. | 0.0 $ | 1000 | GDT 600V 15% 5KA THROUGH ... |
2035-110-SM-RPLF | Bourns Inc. | 0.0 $ | 1000 | GDT 1100V 20% 2.5KA SMDGa... |
2035-9-C5LF | Bourns Inc. | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
2035-9-CLF | Bourns Inc. | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
2035-20-CLF | Bourns Inc. | 0.0 $ | 1000 | GDT 200V 15% 5KA THROUGH ... |
2035-47-C5LF | Bourns Inc. | 0.0 $ | 1000 | GDT 470V 15% 5KA THROUGH ... |
2035-60-C5LF | Bourns Inc. | 0.0 $ | 1000 | GDT 600V -12%, +15% 5KA T... |
2035-2.5KG | 3M | 5.54 $ | 1000 | THERMALLY CONDUCTIVE GREA... |
QK08A-2/203530 | ebm-papst In... | 0.0 $ | 1000 | FAN BLOWER CF 500X200MM 1... |
2035-0 | Pomona Elect... | 5.54 $ | 2054 | HDWR PLUG DBL BANANA SHOR... |
2035-35-BLF | Bourns Inc. | 0.74 $ | 790 | GDT 350V 15% 5KA THROUGH ... |
2035-42-SM-RPLF | Bourns Inc. | -- | 1000 | GDT 420V 15% 5KA SURFACE ... |
2035-09-A | Bourns Inc. | 0.32 $ | 1000 | GDT 90V 20% 5KAGas Discha... |
2035-09-ALF | Bourns Inc. | 0.32 $ | 1000 | GDT 90V 20% 5KAGas Discha... |
2035-15-A | Bourns Inc. | 0.32 $ | 1000 | GDT 150V 15% 5KAGas Disch... |
2035-15-SM | Bourns Inc. | 0.32 $ | 1000 | GDT 150V 15% 5KA SURFACE ... |
2035-15-SMLF | Bourns Inc. | 0.32 $ | 1000 | GDT 150V 15% 5KA SURFACE ... |
2035-20-A | Bourns Inc. | 0.32 $ | 1000 | GDT 200V 15% 5KAGas Disch... |
2035-20-SM | Bourns Inc. | 0.32 $ | 1000 | GDT 200V 15% 5KA SURFACE ... |
2035-23-A | Bourns Inc. | 0.32 $ | 1000 | GDT 230V 15% 5KAGas Disch... |
2035-23-SM | Bourns Inc. | 0.32 $ | 1000 | GDT 230V 15% 5KA SURFACE ... |
2035-23-SMLF | Bourns Inc. | 0.32 $ | 1000 | GDT 230V 15% 5KA SURFACE ... |
2035-25-A | Bourns Inc. | 0.32 $ | 1000 | GDT 250V 15% 5KAGas Disch... |
2035-25-SM | Bourns Inc. | 0.32 $ | 1000 | GDT 250V 15% 5KA SURFACE ... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...