| Allicdata Part #: | 2036-07-B-ND |
| Manufacturer Part#: |
2036-07-B |
| Price: | $ 0.64 |
| Product Category: | Circuit Protection |
| Manufacturer: | Bourns Inc. |
| Short Description: | GDT 75V 20% 10KA THROUGH HOLE |
| More Detail: | Gas Discharge Tube 75V 10000A (10kA) ±20% 3 Pole T... |
| DataSheet: | 2036-07-B Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Contains lead / RoHS non-compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1000 +: | $ 0.58354 |
Specifications
| Series: | Mini-TRIGARD™ 2036 |
| Packaging: | Tray |
| Lead Free Status / RoHS Status: | -- |
| Part Status: | Active |
| Moisture Sensitivity Level (MSL): | -- |
| Voltage - DC Spark Over (Nom): | 75V |
| Impulse Discharge Current (8/20µs): | 10000A (10kA) |
| Tolerance: | ±20% |
| Number of Poles: | 3 |
| Fail Short: | No |
| Mounting Type: | Through Hole |
| Package / Case: | Axial Cylinder, 3 Lead (T-Shape) |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Introduction: A Gas Discharge Tube Arresters (GDT) is an arrester designed to protect electrical and electronic equipment against lightning, power transients, and high voltage surges. It works by interrupting the current flow when exposed to a predetermined level of electrical energy, and prevents further damage to the equipment. It has been a popular choice for protecting devices and systems from electrical surge related shocks and other types of damage since the mid-1960s.Overview of GDTGDTs are an effective and reliable means of protecting devices and systems from the high voltages and current transients caused by lightning. The arrester dissipates the energy of an electrical surge or impulse, often in a fraction of a second. It works by sensing the level of energy, then using a combination of specialized materials and mechanisms, such as spark gap, gas, and specific electrodes, to control the flow of electric current.In order for a GDT to be effective, it must be properly matched to the device and system that it will be protecting. For instance, different types of GDTs will have different levels of protection. For example, some are designed to provide greater protection against higher voltages while others are suitable for lower voltages. In addition, a GDT must also be able to dissipate the energy of an electrical surge or impulse without creating abnormal thermal losses.Application Field and Working Principle of GDTGDTs are commonly used in a variety of applications such as building protection in commercial and industrial settings, consumer electronics, medical and other sensitive equipment, and even in cars and trucks.The most basic form of GDT is composed of two electrodes, a spark gap, and a gas-filled tube. The process of current flow is enabled by the presence of a spark gap situated between the two electrodes. When a voltage surge is detected, the spark gap breaks the circuit and the gas-filled tube begins to dissipate the electrical energy.This process is known as an arc-over and can be used to protect devices from electrical surges. Each spark gap is tailored according to the voltage level at which an arrester must be triggered. This, in turn, ensures the GDT is triggered at the optimal point when the voltage passes through it and effectively protect the system from damage.In addition, GDTs incorporate other mechanisms and materials such as specific electrodes, electromechanical cabling, and metal oxide varistors (MOVs), to provide the maximum level of protection for the device or system that they are protecting.ConclusionGas Discharge Tube Arresters are an essential component of any electrical or electronic device or system. They are designed to protect against high voltage surges, power transients, lightning, and other types of damages. By carefully selecting the correct GDT for the application, users can ensure the highest level of protection for their device or system.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "2036" Included word is 40
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 2036-07-B2 | Bourns Inc. | 0.68 $ | 1000 | GDT 75V 20% 10KA THROUGH ... |
| H1DXS-2036M | ASSMANN WSW ... | 2.3 $ | 1000 | IDC CBL - HHKR20S/AE20M/X... |
| 2036-23-SMLF | Bourns Inc. | 1.37 $ | 488 | GDT 230V 20% 10KA SURFACE... |
| 2036-20-B2LF | Bourns Inc. | 1.51 $ | 1985 | GDT 200V 20% 10KA THROUGH... |
| A3RRA-2036G | TE Connectiv... | 0.0 $ | 1000 | IDC CABLE-APR20A/ AE20G /... |
| 2036-23-C | Bourns Inc. | 0.0 $ | 1000 | GDT 230V 20% 10KA THROUGH... |
| M3FFK-2036R | 3M | 13.07 $ | 1000 | IDC CABLE - MCF20K/MC20M/... |
| A1BXB-2036M | TE Connectiv... | 3.39 $ | 1000 | IDC CABLE- ASR20B/AE20M/X... |
| C1BXS-2036M | CW Industrie... | 3.4 $ | 1000 | IDC CABLE - CSR20S/AE20M/... |
| 2036-09-B2LF | Bourns Inc. | -- | 2882 | GDT 90V 20% 10KA THROUGH ... |
| A3BBH-2036G | TE Connectiv... | 3.76 $ | 1000 | IDC CABLE - ASR20H/AE20G/... |
| A2MXS-2036G | TE Connectiv... | 2.7 $ | 1000 | ADM20S/AE20G/X20 Position... |
| H3DWH-2036G | ASSMANN WSW ... | 4.12 $ | 1000 | IDC CBL- HHKR20H/AE20G/HH... |
| M6MMH-2036J | 3M | 0.0 $ | 1000 | IDC CABLE - MDM20H/MC20G/... |
| A3KKA-2036M | TE Connectiv... | 0.0 $ | 1000 | IDC CABLE- APK20A/ AE20M ... |
| 2036-42-SMLF | Bourns Inc. | 0.62 $ | 1000 | GDT 420V 20% 10KA SURFACE... |
| 2036-09-B2 | Bourns Inc. | 0.68 $ | 1000 | GDT 90V 20% 10KA THROUGH ... |
| M3CCA-2036R | 3M | 4.31 $ | 1000 | IDC CABLE - MKC20A/MC20M/... |
| C3BEG-2036M | CW Industrie... | 8.18 $ | 1000 | IDC CABLE - CSR20G/AE20M/... |
| 2036-35-B | Bourns Inc. | 0.64 $ | 1000 | GDT 350V 20% 10KA THROUGH... |
| H8MMH-2036G | ASSMANN WSW ... | 1.93 $ | 1000 | DIP CABLE - HDM20H/AE20G/... |
| A1DXH-2036M | TE Connectiv... | 3.28 $ | 1000 | IDC CABLE - AKR20H/AE20M/... |
| M3DGK-2036R | 3M | 10.62 $ | 1000 | IDC CABLE - MKR20K/MC20M/... |
| A1BXH-2036M | TE Connectiv... | 3.28 $ | 1000 | IDC CABLE - ASR20H/AE20M/... |
| H2PXS-2036G | ASSMANN WSW ... | 0.0 $ | 1000 | DIP CABLE - HDP20S/AE20G/... |
| 2036-09-ALF | Bourns Inc. | 0.61 $ | 1000 | GDT 90V 20% 10KAGas Disch... |
| 2036-35-ALF | Bourns Inc. | 0.61 $ | 1000 | GDT 350V 20% 10KAGas Disc... |
| H8MMS-2036G | ASSMANN WSW ... | 1.99 $ | 1000 | DIP CBL - HHDM20S/AE20G/H... |
| A1CXH-2036G | TE Connectiv... | 2.24 $ | 1000 | IDC CABLE - AKC20H/AE20G/... |
| A3KKB-2036M | TE Connectiv... | 11.35 $ | 1000 | IDC CABLE - APK20B/AE20M/... |
| 2036-09-BLF | Bourns Inc. | 1.42 $ | 974 | GDT 90V 20% 10KA THROUGH ... |
| 2036-47-A | Bourns Inc. | 0.61 $ | 1000 | GDT 470V 20% 10KAGas Disc... |
| 2036-35-B3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 350V 20% 10KA THROUGH... |
| 2036-23-CLF | Bourns Inc. | 0.0 $ | 1000 | GDT 230V 20% 10KA THROUGH... |
| 2036-25-C3 | Bourns Inc. | 0.0 $ | 1000 | GDT 250V 20% 10KA THROUGH... |
| C3APS-2036M | CW Industrie... | 4.86 $ | 1000 | IDC CABLE - CSC20S/AE20M/... |
| 2036-07-SM-RPLF | Bourns Inc. | -- | 46000 | GDT 75V 20% 10KA SURFACE ... |
| C3DDG-2036M | CW Industrie... | 7.55 $ | 1000 | IDC CABLE - CKR20G/AE20M/... |
| M3AWK-2036J | 3M | 8.53 $ | 1000 | IDC CABLE - MSC20K/MC20G/... |
| M3TKK-2036R | 3M | 9.83 $ | 1000 | IDC CABLE - MSD20K/MC20M/... |
Latest Products
B88069X9960B102
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X9630C152
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X8591B102
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X8291S102
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X7831B502
GAS DISCHARGE TUBEGas Discharge Tube ...
B88069X5131B102
GAS DISCHARGE TUBEGas Discharge Tube ...
2036-07-B Datasheet/PDF