Allicdata Part #: | 2049-47-BLF-ND |
Manufacturer Part#: |
2049-47-BLF |
Price: | $ 0.55 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GDT 470V 30% 15KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 470V 15000A (15kA) ±30% 2 Pole ... |
DataSheet: | ![]() |
Quantity: | 990 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 0.50400 |
5 +: | $ 0.48888 |
10 +: | $ 0.45675 |
50 +: | $ 0.37800 |
100 +: | $ 0.31500 |
250 +: | $ 0.30714 |
500 +: | $ 0.25988 |
1000 +: | $ 0.22838 |
5000 +: | $ 0.20475 |
Series: | 2049 |
Packaging: | Tray |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 470V |
Impulse Discharge Current (8/20µs): | 15000A (15kA) |
Tolerance: | ±30% |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
A Gas Discharge Tube Arresters (GDT) is a device that is used to protect electrical circuits from damage due to external or internal overvoltage or overcurrent. GDTs are typically used in high voltage applications, such as power transmission and distribution systems, and are usually constructed of two ceramic insulators with a metal shield between them. The ceramic insulator acts as a dielectric, while the metal shield creates a spark gap between the two elements. As voltage and current build up within the system, the spark gap will breakdown and discharge an electric current to protect the system from damage. The 2049-47-BLF application field and working principle of GDTs is explained in detail below.
The primary purpose of the 2049-47-BLF application field is to provide an economical range of overvoltage protection products with high current handling capacity. It offers complete protection from transient overvoltages caused by lightning, electrical fault, or atmospheric disturbances. The 2049-47-BLF application field also provides protection from radio interference (RFI). These units are designed for both indoor and outdoor installation and feature a polyester powder coated aluminum enclosure.
The working principle of the 2049-47-BLF application field is based on the protection of electrical circuits from damage caused by overvoltage or overcurrent. As the voltage and current build up within the system, the spark gap between the two elements begins to breakdown and discharge an electric current. The electric current passes through the arrester, protecting the system from damage. The arrester contains two elements: a Zinc Oxide Varistor (ZOV) and a Gas Discharge Tube (GDT). The ZOV acts as a voltage regulator, while the GDT acts as an overvoltage absorber. When the GDT senses an overvoltage, it discharges current and absorbs the excess voltage. The ZOV then works to reduce the voltage that passes through the arrester.
The 2049-47-BLF application field and working principle provides a protective function to power distribution networks that require a reliable protection against intermittent overvoltages. GDTs provide excellent protection against fault currents in situations where a Solid-State Variator (SSV) may not be able to respond fast enough. With its high current handling capacity, the 2049-47-BLF application field and working principle ensures uninterrupted power supply for critical installations and processes.
In conclusion, the 2049-47-BLF application field and working principle provide an economical and reliable means of protecting electrical circuits from damage due to overvoltage or overcurrent. The combination of ZOV and GDT provides optimal protection against intermittent overvoltages, while still offering excellent protection against fault currents. Additionally, with its high current handling capacity, this GDT is an ideal choice for critical power distribution systems.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
2049-23-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 230V 30% 15KA THROUGH... |
UPGHX114-20496-2 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
2049/60 100SF | 3M | 0.0 $ | 1000 | CBL RIBN 60COND 0.025 WHI... |
203-11-20497-1 | Sensata-Airp... | 221.54 $ | 1000 | CIR BRKR ROCKER |
2049-09-BLF | Bourns Inc. | 0.55 $ | 356 | GDT 90V 30% 15KA THROUGH ... |
2049-23-BLF | Bourns Inc. | 0.55 $ | 750 | GDT 230V 30% 15KA THROUGH... |
2049-47-BLF | Bourns Inc. | 0.55 $ | 990 | GDT 470V 30% 15KA THROUGH... |
M39018/04-2049M | Cornell Dubi... | 71.22 $ | 1000 | ALUM-SCREW TERMINALAlumin... |
2049/68 300 | 3M | 0.0 $ | 1000 | CBL RIBN 68COND 0.025 WHI... |
204980 | Weidmuller | 4.03 $ | 1000 | DK 4/32;3 CLAMP THRU SDRB... |
2049-60-BLF | Bourns Inc. | -- | 26 | GDT 600V 30% 15KA THROUGH... |
M39003/09-2049/HSD | Vishay Sprag... | 24.91 $ | 1000 | CAP TANT 82UF 10% 20V AXI... |
70156-2049 | Omron Automa... | 4.16 $ | 1000 | SYSTEM |
2049/20 300 | 3M | 0.0 $ | 1000 | CBL RIBN 20COND 0.025 WHI... |
10124383-2049LF | Amphenol FCI | 17.82 $ | 1000 | BERGSTIK |
2049/80 300 | 3M | 0.0 $ | 1000 | CBL RIBN 80COND 0.025 WHI... |
2049/100 300 | 3M | 0.0 $ | 1000 | CBL RIBN 100COND 0.025 WH... |
2049261103 | Molex, LLC | -- | 1000 | WATER PROOF MICRO USBUSB ... |
2049-40-BLF | Bourns Inc. | 0.55 $ | 1579 | GDT 400V 30% 15KA THROUGH... |
2049-07-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 75V 30% 15KA THROUGH ... |
M39003/09-2049H | Vishay Sprag... | 24.86 $ | 1000 | CAP TANT 82UF 10% 20V AXI... |
2049-14-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 145V 30% 15KA THROUGH... |
2049-47-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 470V 30% 15KA THROUGH... |
204978-3 | TE Connectiv... | 5.83 $ | 1000 | CONN PIN SIZE 16 GOLDCont... |
20490-004-XTP | ON Semicondu... | 0.0 $ | 1000 | IC ENERGY MANAGEMENT |
20490-004-XTD | ON Semicondu... | 0.0 $ | 1000 | IC ENERGY MANAGEMENT |
2049/60 300 | 3M | 0.0 $ | 1000 | CBL RIBN 60COND 0.025 WHI... |
2049-35-BLF | Bourns Inc. | 0.55 $ | 3500 | GDT 350V 30% 15KA THROUGH... |
2049-13-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 130V 30% 15KA THROUGH... |
2049/40 100SF | 3M | 0.0 $ | 1000 | CBL RIBN 40COND 0.025 WHI... |
2049-09-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 90V 30% 15KA THROUGH ... |
RH31M-4/204988 | ebm-papst In... | 0.0 $ | 1000 | FAN IMP MTRZD 317X210MM 2... |
204968 | Weidmuller | 7.11 $ | 1000 | DK 4/32;3 CLAMP SPLIT SOL... |
2049-25-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 250V 30% 15KA THROUGH... |
2049-13-BLF | Bourns Inc. | 0.25 $ | 1000 | GDT 130V 30% 15KA THROUGH... |
2049-12-BLF | Bourns Inc. | 0.25 $ | 1000 | GDT 120V 30% 15KA THROUGH... |
UPGHX14-20496-3 | Sensata-Airp... | 0.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
203-11-2049-1 | Sensata-Airp... | 244.25 $ | 1000 | CIR BRKR ROCKER |
M39003/03-2049/HSD | Vishay Sprag... | 4.12 $ | 1000 | CAP TANT 3.9UF 10% 20V AX... |
2049-35-BT1LF | Bourns Inc. | 0.27 $ | 1000 | GDT 350V 30% 15KA THROUGH... |
GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...