2095-250-BLF Allicdata Electronics
Allicdata Part #:

2095-250-BLF-ND

Manufacturer Part#:

2095-250-BLF

Price: $ 0.98
Product Category:

Circuit Protection

Manufacturer: Bourns Inc.
Short Description: GDT 2500V 20% 5KA THROUGH HOLE
More Detail: Gas Discharge Tube 2500V 5000A (5kA) ±20% 2 Pole T...
DataSheet: 2095-250-BLF datasheet2095-250-BLF Datasheet/PDF
Quantity: 375
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1 +: $ 0.88830
5 +: $ 0.85932
10 +: $ 0.80388
50 +: $ 0.66528
100 +: $ 0.55440
250 +: $ 0.54054
500 +: $ 0.45738
1000 +: $ 0.40194
5000 +: $ 0.36036
Stock 375Can Ship Immediately
$ 0.98
Specifications
Series: 2095
Packaging: Bulk 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 2500V
Impulse Discharge Current (8/20µs): 5000A (5kA)
Tolerance: ±20%
Number of Poles: 2
Fail Short: No
Mounting Type: Through Hole
Package / Case: Axial Cylinder
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube Arresters (GDT)

Gas discharge tube arrester (GDT) is a device used for protecting electrical circuits appointed during short depending spikes or electrical transients, usually during switching events or lightning strikes. It can be used for protecting equipments like transformers, circuit breakers, generators and so on in three phase and single phase AC circuits. GDT works based on the ability of gas discharge tubes to absorb the sudden and intense energy caused by a short or transient. GDT like 2095-250-BLF consists of a gas discharge tube and a spark gap. The spark gap has a threshold voltage. When the threshold voltage is reached, a spark will occur between the contacts, allowing the sudden peak transient energy to pass through, and then quickly extinguishes itself. The gas discharge tube (GDT) is placed downstream of the spark gap, creating an electrical reference point where the transient energy is grounded.The primary application of GDT like 2095-250-BLF is providing protection of telecomm and power equipment from overvoltages caused by external events such as lightning strikes or switching events. Its design and construction ensures that normal system voltage cannot exceed the level that triggers its operation.The working principle of GDT 2095-250-BLF consists of two stages. The first stage is the spark gap, which interrupts normal voltage, and then the second stage is the GDT, which dissipate large surges current depending on the selected rated current. The gap has a preset voltage rating and when the external voltage exceeds this rating, a spark will be created in which the energy is discharged. The gas discharge tube, on the other hand, acts as a preventative measure for any additional transient voltages that still pass through the spark gap. The GDT blocks further energy from passing and creates an electrical reference through which the energy is grounded.By nature, GDT devices can also provide surge protection against severe over-voltages caused by lightning, ensuring that the equipment is kept safe. GDT devices such as 2095-250-BLF are used in telecom, power generation and distribution system protection because of their high surge capacity and low energy loss. GDT like 2095-250-BLF helps to ensure the reliability of systems by protecting the electronic circuits and equipment from hazardous high-energy voltaic transients like power swings, switching transients and lightning. Such devices are becoming increasingly sophisticated, with more and more modular designs and multi-stage systems available. This allows users to customize a system to meet their particular needs.In summary, 2095-250-BLF GDT devices consists of two stages, namely the spark gaps and the GDT. The spark gap has a preset voltage rating and when the external voltage exceeds this rating, a spark will be created in which the energy is discharged. The GDT creates an electrical reference point where the transient energy is grounded. GDT are used for protecting telecom and power equipment from overvoltages caused by external events such as lightning strikes or switching events. The primary purpose of GDT is to maintain system reliability and protect electronic circuits and equipment from high-energy transients.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "2095" Included word is 40
Part Number Manufacturer Price Quantity Description
MS46LR-30-2095-Q1-10X-10R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46SR-30-2095-Q1-30X-15R-NC-A Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q2-10X-10R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q1-10X-10R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
2095-450-BT1LF Bourns Inc. 0.47 $ 1000 GDT 4500V 20% 5KA THROUGH...
2095-500-CLF Bourns Inc. 0.47 $ 1000 GDT 5000V 20% 5KA THROUGH...
2095-160-BLF Bourns Inc. 0.98 $ 176 GDT 1600V 20% 5KA THROUGH...
2095-80-BLF Bourns Inc. 0.98 $ 763 GDT 800V 20% 5KA THROUGH ...
2095-400-BLF Bourns Inc. 0.98 $ 893 GDT 4000V 20% 5KA THROUGH...
MS46LR-30-2095-Q1-10X-15R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q1-R-NC-FN Omron Automa... 0.0 $ 1000 SPARE RECEIVER
ATD 2095 Astro Tool C... 64.95 $ 1000 TOOL REMOVAL 20 GA
MS46SR-30-2095-Q1-15X-10R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
20952000004 HARTING 30.09 $ 3 DIN RAIL MOUNTING ADAPTER
MS46SR-30-2095-Q2-30X-15R-NC-A Omron Automa... 0.0 $ 1000 SYSTEM
2095-600-CT1LF Bourns Inc. 0.48 $ 1000 GDT 6000V 20% 5KA THROUGH...
20953000007 HARTING 23.16 $ 2 WALL MOUNTING KIT
MS46SR-30-2095-Q1-00X-00R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q1-R-NO-FP Omron Automa... 0.0 $ 1000 SPARE RECEIVER
MS46LR-30-2095-Q2-10X-10R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
2095-450-BLF Bourns Inc. 0.44 $ 1000 GDT 4500V 20% 5KA THROUGH...
MS46SR-30-2095-Q2-30X-30R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
22-01-2095 Molex, LLC 0.0 $ 1000 CONN HSNG 9POS .100 W/RAM...
MS46LR-30-2095-Q1-R-NC-FP Omron Automa... 0.0 $ 1000 SPARE RECEIVER
2095-250-BLF Bourns Inc. 0.98 $ 375 GDT 2500V 20% 5KA THROUGH...
MS46LR-30-2095-Q1-30X-30R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46SR-30-2095-Q2-10X-10R-NO-A Omron Automa... 0.0 $ 1000 SYSTEM
030-2095-000 ITT Cannon, ... 0.0 $ 1000 38999 II CON PIN 2225 HD ...
MS46SR-30-2095-Q1-15X-15R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q1-30X-30R-NC-A Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q2-30X-30R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
MS46LR-30-2095-Q2-15X-15R-NO-A Omron Automa... 0.0 $ 1000 SYSTEM
2095-250-BT1LF Bourns Inc. 0.47 $ 1000 GDT 2500V 20% 5KA THROUGH...
2095-200-BLF Bourns Inc. 0.44 $ 1000 GDT 2000V 20% 5KA THROUGH...
MS46SR-30-2095-Q1-R-NC-FN Omron Automa... 0.0 $ 1000 SPARE RECEIVER
2095-400-BT1LF Bourns Inc. 0.47 $ 1000 GDT 4000V 20% 5KA THROUGH...
MS46SR-30-2095-Q1-30X-15R-NC-F Omron Automa... 0.0 $ 1000 SYSTEM
PEF 20954 HT V1.1 Infineon Tec... 0.0 $ 1000 IC ECHO CANCELLER DGTL TQ...
MS46SR-30-2095-Q1-15X-15R-NC-A Omron Automa... 0.0 $ 1000 SYSTEM
MS46SR-30-2095-Q1-10X-10R-NO-F Omron Automa... 0.0 $ 1000 SYSTEM
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics