Allicdata Part #: | 277-7052-ND |
Manufacturer Part#: |
2788977 |
Price: | $ 93.56 |
Product Category: | Filters |
Manufacturer: | Phoenix Contact |
Short Description: | LINE FILTER 264VAC 10A DIN RAIL |
More Detail: | N/A |
DataSheet: | 2788977 Datasheet/PDF |
Quantity: | 22 |
1 +: | $ 85.05000 |
10 +: | $ 78.24600 |
50 +: | $ 72.29250 |
Specifications
Series: | -- |
Part Status: | Active |
Filter Type: | Single Phase |
Configuration: | Single Stage |
Voltage - Rated DC: | -- |
Voltage - Rated AC: | 264V |
Current: | 10A |
Frequency - Operating: | 50/60Hz |
Applications: | General Purpose |
Approvals: | GOST, UR, VDE |
Operating Temperature: | -25°C ~ 100°C |
Mounting Type: | DIN Rail |
Termination Style: | Terminal Block |
Inductance: | 1.8mH |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Introduction
Power line filter modules are widely used in different areas such as consumer and industrial electronics, automotive systems, consumer AC power systems, etc. They are basically designed to ensure the harmonic integrity of an electrical system, that is, reduce the unexpected or distorted electrical signal caused by interference. Typically, the filter module contains two components, an inductive element (inductance) and a capacitive element (capacitance).Application field
Generally speaking, the most common application of a power line filter module is to reduce the effects of conducted interference on the supplied power lines. In order to achieve this goal, the filter must effectively reduce how much of the conducted interference energy reaches the device that is being protected. The most important application of power line filter modules is to reduce harmful electromagnetic interference (EMI). EMI is a form of pollution where low levels of energy are usually generated by electrical or electronic devices and radiated through air. In addition, a power line filter module can also be used to reduce high frequency noise on power supply lines.Working Principle
The working principle of power line filter modules is to create an inductive field that absorbs and reduces the unwanted electrical signals from reaching the device it is protecting. This is done by providing an impedance to the interference signal so that the unwanted energy is effectively blocked or "filtered" away from reaching the device. The inductive element of the power line filter module works to reduce the effects of high frequency interference. It does this by creating an inductive field with its coils and the capacitive element works to reduce the effects of low frequency interference. The capacitor acts as a short circuit and absorbs the low frequency energy.Conclusion
Power line filter modules are an important element of any electrical system. Their main advantage is that they help reduce the amount of conducted interference that is reaching the device they are protecting, thus improving the performance of the electrical system. Additionally, they can also be used to reduce the amount of high frequency noise on power supply lines. No matter what type of power line filter module is used, it is important to ensure that it has the correct components and is properly implemented to reduce the negative effects of interference on the system. In this way, the system can operate at peak performance, which can increase its overall efficiency and reliability.The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "2788" Included word is 28
Part Number | Manufacturer | Price | Quantity | Description |
---|
2788935 | Phoenix Cont... | 0.0 $ | 1000 | DIN RAIL MODULE W/SURGE P... |
IULHK12-27887-1 | Sensata-Airp... | 134.24 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
2788401 | Phoenix Cont... | 9.99 $ | 57 | BASE ELEMENT W/FOOT |
IEGH66-27889-3-V | Sensata-Airp... | 57.6 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
2788-3 | Eaton | 325.9 $ | 1000 | BUSS FUSEBLOCKFuse |
IULHK112-27886-1 | Sensata-Airp... | 188.21 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
IULN004-27884-2 | Sensata-Airp... | 193.06 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
2788977 | Phoenix Cont... | 93.56 $ | 22 | LINE FILTER 264VAC 10A DI... |
MIKROE-2788 | MikroElektro... | 20.71 $ | 9 | PIC32MZ CLICKERPIC32MZ Cl... |
M39003/01-2788/TR | Vishay Sprag... | 7.59 $ | 1000 | CAP TANT 27UF 10% 35V AXI... |
M39003/01-2788 | Vishay Sprag... | 9.89 $ | 1000 | CAP TANT 27UF 10% 35V AXI... |
M39003/01-2788H | Vishay Sprag... | 9.89 $ | 1000 | CAP TANT 27UF 10% 35V AXI... |
2788061 | Phoenix Cont... | 14.69 $ | 1000 | CONN TERM BLK DISCONN 12-... |
2788281 | Phoenix Cont... | 18.41 $ | 1000 | CONN TERM BLK DISCONNECT ... |
2788090 | Phoenix Cont... | 18.92 $ | 1000 | CONN TERM BLK FEED THRU 1... |
2788249 | Phoenix Cont... | 24.26 $ | 1000 | CONN TERM BLK FEED THRU 1... |
2788278 | Phoenix Cont... | 27.13 $ | 1000 | CONN TERM BLK DISCONNECT ... |
2788207 | Phoenix Cont... | 31.35 $ | 1000 | CONN TERM BLK FEED THRU 1... |
2788210 | Phoenix Cont... | 32.29 $ | 1000 | CONN TERM BLK DISCONN 12-... |
2788236 | Phoenix Cont... | 0.0 $ | 1000 | CONN TERM BLK DISCONNECT ... |
2788 | Adafruit Ind... | 0.67 $ | 47 | 3.5 / 1.3MM OR 3.8 / 1.1M... |
2788896 | Phoenix Cont... | 280.39 $ | 1000 | BOX ALUM GRAY 5.28"L X 4.... |
2788304 | Phoenix Cont... | 9.12 $ | 1000 | CONN TERM BLKTerminal Blo... |
IEL111-27888-1-V | Sensata-Airp... | 149.0 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
2788391 | Phoenix Cont... | 9.08 $ | 1000 | VARISTOR 24V 350A MODULE2... |
2788.0 | Altech Corpo... | 2.16 $ | 1000 | H120.0/27 INSULATED4/0AWG... |
70156-2788 | Omron Automa... | 3.47 $ | 1000 | SYSTEM |
M39003/01-2788/HSD | Vishay Sprag... | 9.96 $ | 1000 | CAP TANT 27UF 10% 35V AXI... |
Latest Products
20EB11
LINE FILTER 250VAC 20A CHASS MNT
5500.2133
LINE FILTER 125/250VAC 4A TH
FTA-100-104-H
LINE FILTER 500VAC 100A CHASSIS
F3480T050
LINE FILTER 480VAC 50A CHASS MNT
FMAC-0934-3610
LINE FILTER 480/520VAC 36A CHASS
FMBC-0997-6500
LINE FILTER 480VAC 65A CHASS MNT