2DU8L Allicdata Electronics
Allicdata Part #:

1920-1591-ND

Manufacturer Part#:

2DU8L

Price: $ 34.93
Product Category:

Circuit Protection

Manufacturer: Altech Corporation
Short Description: CIR BRKR THRM-MAG 8A LEVER
More Detail: N/A
DataSheet: 2DU8L datasheet2DU8L Datasheet/PDF
Quantity: 12
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1 +: $ 31.75200
5 +: $ 30.24000
10 +: $ 27.97200
50 +: $ 24.19200
100 +: $ 22.68000
250 +: $ 21.16800
Stock 12Can Ship Immediately
$ 34.93
Specifications
Series: L
Part Status: Active
Lead Free Status / RoHS Status: --
Breaker Type: Thermal Magnetic
Moisture Sensitivity Level (MSL): --
Current Rating: 8A
Voltage Rating - AC: 480V
Voltage Rating - DC: 250V
Number of Poles: 2
Actuator Type: Lever
Illumination: None
Illumination Voltage (Nominal): --
Mounting Type: DIN Rail
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Circuit breakers have become essential components of electronic electrical systems, particularly in areas requiring frequent or extreme power switching. With advances in technology, the components of a circuit breaker and their working principles have changed over the years. This article will discuss the 2DU8L application field and working principle as they relate to circuit breakers.

The 2DU8L series is a heavy-duty industrial-grade, three-pole circuit breaker designed for the toughest environment. It has the capability to control and protect high voltage and current surges in different locations, such as airport runway lighting, low voltage lighting, pump stations, and water and sewer systems. This circuit breaker has an advanced solenoid control system that allows it to easily switch from a normal open to a normal closed position in just milliseconds, which gives it the ability to quickly respond to large power surges which could potentially be hazardous.

The working principle of the 2DU8L circuit breaker relies on the solenoid principle. A solenoid core consists of two coils of wire wound around an inert ferrous core. When there is a power surge, the solenoid will pull the circuit breaker’s core in towards the center of the solenoid, which will cause the entire circuit breaker to completely shut off. The solenoid is also designed to prevent false trips, so that it won’t switch off even if there is a sudden or minor power surge. When the power surge is large enough, however, the solenoid core is pulled in quickly and the circuit breaker will shut down immediately.

The 2DU8L circuit breaker has a number of safety features thathelp protect equipment from potential damage due to power surges. For example, it has a self-resetting thermal overload protection feature that will trip the breaker when the current is excessive and automatically reset itself when the current flow decreases. This helps to protect expensive and sensitive equipment from the damage that can be caused by surges. Additionally, the circuit breaker is equipped with a reset timer that prevents it from causing damage to eqmpuipment by limiting the duration of the electrical current.

The 2DU8L circuit breaker is also equipped with a capacitor that increases the response time of the circuit breaker. This helps the breaker respond more quickly to large surges and helps protect sensitive and expensive equipment from damaging power spikes. Furthermore, the breaker is designed to be used in environments with temperatures ranging from minus 40 to 60 degrees Celsius, as well as in areas with high humidity levels.

The 2DU8L series is an industrial-grade, three-pole circuit breaker that has been designed for the most extreme circumstances. It offers advanced control and protection of high voltage and current surges in different locations, such as airport runway lighting, low voltage lighting, pump stations, and water and sewage systems. The working principle of the 2DU8L relies on the solenoid principle, which consists of two coils of wire wound around an inert ferrous core. Additionally, this circuit breaker includes a number of safety features to protect equipment from potential damage caused by power surges. It has a number of response time increasing capabilities, as well as a built-in temperature range tolerance, which makes it suitable for extreme conditions.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "2DU8" Included word is 2
Part Number Manufacturer Price Quantity Description
2DU8L Altech Corpo... 34.93 $ 12 CIR BRKR THRM-MAG 8A LEVE...
2DU8R Altech Corpo... 16.63 $ 1000 2DU8R8A MCBDCHAR2P 480Y/2...
Latest Products
UPG11-4038-10

CIRCUIT BREAKER MAG-HYDR LEVER

UPG11-4038-10 Allicdata Electronics
299-3-3283-14

CIRCUIT BREAKER MAG-HYDR LEVER

299-3-3283-14 Allicdata Electronics
JLE-1-1REG4-52-3-B1-200-A...

CIR BRKR MAG-HYDR 200A 160VDC

JLE-1-1REG4-52-3-B1-200-A-V Allicdata Electronics
IEGH666-1REC4-72-32.0-01-...

CIR BRKR MAG-HYDR

IEGH666-1REC4-72-32.0-01-V Allicdata Electronics
483-G641-K1M1-A1S0ZN-5A

CIRC BRKR THRM

483-G641-K1M1-A1S0ZN-5A Allicdata Electronics
IEG111-1-52-10.0-01-V

CIR BRKR MAG-HYDR LEVER 10A

IEG111-1-52-10.0-01-V Allicdata Electronics