3404.0118.22 Circuit Protection |
|
Allicdata Part #: | 486-3871-2-ND |
Manufacturer Part#: |
3404.0118.22 |
Price: | $ 0.29 |
Product Category: | Circuit Protection |
Manufacturer: | Schurter Inc. |
Short Description: | FUSE BRD MNT 3A 125VAC/VDC 2SMD |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 3750 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
750 +: | $ 0.26555 |
1500 +: | $ 0.24784 |
5250 +: | $ 0.23545 |
Response Time: | Slow |
Size / Dimension: | 0.291" L x 0.122" W x 0.102" H (7.40mm x 3.10mm x 2.60mm) |
Color: | -- |
Operating Temperature: | -40°C ~ 85°C |
Approvals: | cURus |
Melting I²t: | 8.06 |
Breaking Capacity @ Rated Voltage: | 100A |
Mounting Type: | Surface Mount |
Package / Case: | 2-SMD, J-Lead |
Series: | OMT 125 |
Voltage Rating - DC: | 125V |
Voltage Rating - AC: | 125V |
Current Rating: | 3A |
Fuse Type: | Board Mount (Cartridge Style Excluded) |
Moisture Sensitivity Level (MSL): | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Packaging: | Tape & Reel (TR) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses
A fuse is an electromechanical device typically used to protect against over-current or short-circuiting in an electrical power system. It is a device used to protect against excessive current, usually caused by accidents, and may have a power cutoff range set so that it will be triggered in the event of an over-current/short-circuiting situation. The 3404.0118.22 Fuse is one such device designed to provide protection in the event of an electrical emergency. This article will discuss the application field and working principle of the 3404.0118.22 fuse.
Application Field
The 3404.0118.22 fuse has been designed primarily as a protection device in electrical appliances. It can be used in a variety of electrical applications, such as in air conditioners, refrigerators, TVs, and other electronic appliances. Additionally, the 3404.0118.22 fuse can also be used in heavy-duty industrial applications, such as power supplies, motor controllers, lighting systems, and more.
The 3404.0118.22 fuse is designed to provide protection against over-current/short-circuiting situations. It has a nominal voltage of 600 volts, a maximum continuous current rating of 32 amperes, and an interrupting current rating of 16 kiloampers. This fuse is also UL listed, meaning it has met the requirements of Underwriters Laboratories and is approved for use in the United States and Canada.
Working Principle
The 3404.0118.22 fuse is designed to protect electrical systems from over-current/short-circuiting situations. When the current flowing through the fuse exceeds its capabilities, the device\'s link material inside will expand and break the electrical circuit. This will protect the system by preventing any further damage due to the excessive current flow.
The 3404.0118.22 fuse is a one-time fuse. This means that, in the case of an over-current/short-circuiting situation, the fuse will be destroyed and will need to be replaced after the situation is resolved. The advantage of this is that the system will be protected from future overloads and short-circuiting occurrences.
The 3404.0118.22 fuse is a reliable and widely used protection device. It is a UL listed device, meaning it has been tested and approved for use in the United States and Canada, and can be used in a variety of applications, from light-duty appliances to heavy-duty industrial systems.
Conclusion
The 3404.0118.22 fuse is a reliable and widely used protection device designed to provide protection against over-current/short-circuiting situations. It is a UL listed device and can be used in light-duty appliances and heavy-duty industrial systems. Additionally, the 3404.0118.22 fuse is a one-time fuse, meaning it will need to be replaced after an over-current/short-circuiting event.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
133-3404-101 | Cinch Connec... | 3.86 $ | 102 | CONN MCX PLUG R/A 50OHM S... |
3404.0119.11 | Schurter Inc... | 0.43 $ | 400 | FUSE BRD MNT 3.5A 125VAC/... |
3404.0015.22 | Schurter Inc... | 0.3 $ | 1000 | FUSE BRD MNT 3.5A 125VAC/... |
3404.2466.11 | Schurter Inc... | -- | 1000 | FUSE BRD MNT 250VAC/125VD... |
3404.2326.11 | Schurter Inc... | 1.27 $ | 200 | FUSE BOARD MNT 2A 125VAC/... |
3404.0120.24 | Schurter Inc... | -- | 1000 | FUSE BRD MNT 4A 125VAC/VD... |
XG4T-3404 | Omron Electr... | 0.47 $ | 200 | STRAIN RELIEF 34POS FLAT ... |
135-3404-001 | Cinch Connec... | 6.94 $ | 50 | CONN MMCX PLUG STR 50 OHM... |
3404.0118.22 | Schurter Inc... | 0.29 $ | 3750 | FUSE BRD MNT 3A 125VAC/VD... |
3404.2321.23 | Schurter Inc... | 0.85 $ | 1000 | FUSE BOARD MNT 375MA 125V... |
3404.2345.11 | Schurter Inc... | 1.18 $ | 1000 | FUSE BOARD MNT 500MA 125V... |
131-3404-021 | Cinch Connec... | 5.08 $ | 1000 | CONN SMB PLUG STR 50 OHM ... |
3404.2330.11 | Schurter Inc... | 0.94 $ | 1000 | FUSE BRD MNT 4A 125VAC/VD... |
3404.2331.23 | Schurter Inc... | 0.85 $ | 1000 | FUSE BRD MNT 5A 125VAC/VD... |
133-3404-001 | Cinch Connec... | 3.77 $ | 1000 | CONN MCX PLUG STR 50 OHM ... |
3404.0020.24 | Schurter Inc... | 0.28 $ | 1000 | FUSE BRD MNT 8A 125VAC/VD... |
3404.2320.23 | Schurter Inc... | 0.85 $ | 1000 | FUSE BOARD MNT 250MA 125V... |
3404.0020.11 | Schurter Inc... | 0.44 $ | 488 | FUSE BRD MNT 8A 125VAC/VD... |
3404.0044.11 | Schurter Inc... | 0.34 $ | 1000 | FUSE BOARD MNT 375MA 125V... |
3404.0046.11 | Schurter Inc... | 0.44 $ | 400 | FUSE BOARD MNT 750MA 125V... |
3404.0122.11 | Schurter Inc... | 0.43 $ | 1000 | OMT 125 FUSE 6.3A T |
3404.2321.22 | Schurter Inc... | 0.91 $ | 1000 | FUSE BOARD MNT 375MA 125V... |
3404.2308.11 | Schurter Inc... | 1.18 $ | 1000 | FUSE BOARD MNT 630MA 125V... |
3404.0116.11 | Schurter Inc... | 0.43 $ | 2389 | FUSE BOARD MNT 2A 125VAC/... |
3404.0113.22 | Schurter Inc... | 0.29 $ | 1000 | FUSE BOARD MNT 750MA 125V... |
133-3404-006 | Cinch Connec... | 2.51 $ | 1000 | CONN MCX PLUG STR 50 OHM ... |
3404.0114.24 | Schurter Inc... | 0.27 $ | 1000 | FUSE BRD MNT 1A 125VAC/VD... |
3404.0112.22 | Schurter Inc... | 0.29 $ | 1000 | FUSE BOARD MNT 500MA 125V... |
3404.0043.11 | Schurter Inc... | 0.44 $ | 430 | FUSE BOARD MNT 350MA 125V... |
3404.0021.22 | Schurter Inc... | -- | 6750 | FUSE BRD MNT 10A 125VAC/V... |
3404.2418.11 | Schurter Inc... | 1.02 $ | 400 | FUSE BRD MNT 1.6A 277VAC ... |
3404-0-00-80-00-00-03-4 | Mill-Max Man... | 0.34 $ | 1000 | CONN PC PIN CIRCPC Pin Te... |
3404.0046.22 | Schurter Inc... | 0.3 $ | 1000 | FUSE BOARD MNT 750MA 125V... |
3404.2323.22 | Schurter Inc... | 0.91 $ | 1000 | FUSE BOARD MNT 750MA 125V... |
3404.0006.11 | Schurter Inc... | 0.43 $ | 157 | FUSE BOARD MNT 250MA 125V... |
3404.0019.24 | Schurter Inc... | 0.28 $ | 1000 | FUSE BRD MNT 7A 125VAC/VD... |
3404.0016.11 | Schurter Inc... | -- | 670 | FUSE BRD MNT 4A 125VAC/VD... |
3404.0009.22 | Schurter Inc... | 0.3 $ | 1000 | FUSE BRD MNT 1A 125VAC/VD... |
3404.2325.11 | Schurter Inc... | 0.94 $ | 1000 | FUSE BRD MNT 1.5A 125VAC/... |
131-3404-101 | Cinch Connec... | 4.68 $ | 1000 | CONN SMB PLUG R/A 50 OHM ... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD

FUSE BOARD MNT 3.15A 125VAC/VDC

FUSE BOARD MNT 350MA 125VAC/VDC

FUSE BRD MNT 2.5A 125VAC/VDC SMD

FUSE BRD MNT 1.6A 125VAC/VDC SMD

FUSE BOARD MNT 1A 250VAC RADIAL