Allicdata Part #: | 1920-1553-ND |
Manufacturer Part#: |
3G30UM |
Price: | $ 37.42 |
Product Category: | Circuit Protection |
Manufacturer: | Altech Corporation |
Short Description: | CIR BRKR THRM-MAG 30A LEVER |
More Detail: | N/A |
DataSheet: | ![]() |
Quantity: | 12 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 34.02000 |
5 +: | $ 32.31900 |
10 +: | $ 30.61800 |
50 +: | $ 25.51500 |
100 +: | $ 23.81400 |
250 +: | $ 22.11300 |
Series: | UM |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal Magnetic |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 30A |
Voltage Rating - AC: | 480V |
Number of Poles: | 3 |
Actuator Type: | Lever |
Illumination: | None |
Illumination Voltage (Nominal): | -- |
Mounting Type: | DIN Rail |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are devices used to protect electrical circuits from damage incidents caused by overloads, short circuits and ground faults. They are designed to detect and respond to dangerous levels of current, as well as providing a visible indicator, alerting operators to any issues. 3G30UM circuit breakers are specially designed for applications that require superior protection features and outstanding performance. In this article, we will discuss the application fields of 3G30UM circuit breakers, as well as the working principles that make them so reliable.
Application Fields
3G30UM circuit breakers are commonly used in medium voltage applications, such as motor control centers, UPS systems, electrical power distribution systems, and high rise buildings. These circuit breakers provide superior protection features and are able to withstand extended overload and short circuit currents. They are designed to detect and respond quickly to dangerous levels of current, as well as providing a visible indicator.
For example, 3G30UM circuit breakers can be used in high rise buildings, providing superior protection from a cascade of overload and short circuit events. When the overload events exceed their preset protection thresholds, the circuit breaker will react and trips the circuit. This allows the 3G30UM circuit breakers to quickly respond and shut down the circuit in the event of an overload, thereby protecting the building’s electrical systems.
In addition, 3G30UM circuit breakers are also commonly used in motor control centers, ups systems, and electrical power distribution systems. These breakers provide reliable and cost-effective protection from overloads, as well as providing an easy to monitor and clearly visible indicator. For example, in electrical power distribution systems, these circuit breakers are used to protect the system from overloads and short circuits, as well as providing an easy to read indicator system.
Working Principles
3G30UM circuit breakers use an integrated solid-state trip unit that incorporates a microprocessor core, advanced logical control and digital signal processing. This trip unit is capable of monitoring the incoming current, comparing it to the preset overload and short circuit protection thresholds and responding immediately if necessary. When sizing the breakers, they are typically installed such that they can withstand twice the motor full-load current as detected by the microprocessor.
The 3G30UM circuit breakers employ a number of different elements that help provide protection against dangerous levels of current. The devices are typically equipped with a thermal-magnetic trip unit that monitors the incoming current levels and is capable of responding immediately if necessary. This trip unit is also equipped with a thermal element that detects the temperature of the incoming current and shut off the breaker if it is too hot. In addition, the circuit breakers are also equipped with a magnetic trip unit that detects the presence of a high level of inductive current in the electrical system.
The 3G30UM circuit breakers also feature an adjustable instantaneous current setting, which is used to adjust the level of current the breaker can withstand before responding. This setting allows the breaker to be adjusted in order to provide protection against short circuit or overload events. This setting can be easily adjusted on a standard circuit breaker panel.
Finally, the 3G30UM circuit breakers employ a stationary contact system. The stationary contact system ensures that the breaker will maintain contact with the incoming current even if the current levels vary significantly over time. This helps to ensure that the breaker will be able to respond quickly to any level of current, without the need to constantly readjust the settings.
In conclusion, 3G30UM circuit breakers are specially designed devices that provide superior protection features, outstanding performance and reliable protection from a range of dangerous levels of current. As discussed above, these circuit breakers can be used in a range of application fields, such as Motor Control Centers and Electrical Power Distribution systems. Moreover, the working principles that make the 3G30UM circuit breakers so reliable include a number of elements, such as a thermal-magnetic trip unit, magnetic trip units, adjustable instantaneous current settings and a stationary contact system.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
3G30UM | Altech Corpo... | 37.42 $ | 12 | CIR BRKR THRM-MAG 30A LEV... |
CIRCUIT BREAKER MAG-HYDR LEVER

CIRCUIT BREAKER MAG-HYDR LEVER

CIR BRKR MAG-HYDR 200A 160VDC

CIR BRKR MAG-HYDR

CIRC BRKR THRM

CIR BRKR MAG-HYDR LEVER 10A