Allicdata Part #: | 5MCLS-3R-B-ND |
Manufacturer Part#: |
5MCLS-3R-B |
Price: | $ 0.69 |
Product Category: | Circuit Protection |
Manufacturer: | Eaton |
Short Description: | MV R RATED FUSE |
More Detail: | N/A |
DataSheet: | 5MCLS-3R-B Datasheet/PDF |
Quantity: | 1000 |
1 +: | $ 0.63000 |
Series: | * |
Part Status: | Active |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses have been used for decades to protect equipment and wiring from damage due to overload or short circuits. A common type of fuse is the 5MCLS-3R-B. It is designed for low-voltage panelboards, switchgear, and other motor control equipment and used in industrial and commercial applications.
Application Field
The 5MCLS-3R-B fuse is suitable for operation at 600V or less. It contains a molded epoxy housing, which keeps the internal components protected from the environment. This design also makes it suitable for indoor, outdoor, underground, or wet locations. Additionally, because the fuse is temperature-rated for 75°C, it can be used in areas with high ambient temperatures.
The 5MCLS-3R-B is designed for use in AC systems. It is suitable for use on systems having an up to 600V isolation between hot and ground, neutral, and/or control circuits. Additionally, its application is not limited to AC motor control equipment. It has been used to protect other types of equipment including power supplies, transformers, rectifiers, and battery chargers.
Working Principle
The 5MCLS-3R-B fuse contains a cylindrical shape. Inside the cylindrical shape, a capsule is filled with a non-conductive material and a metal fuse element made from nickel, copper, or silver. When the current passes through the fuse element, it produces over-heating and melts the fuse element.
Once the fuse element has been melted, a spring mechanism pushes a plug up from the fuse to break the circuit. This opening of the circuit halts the current flow and thus protects the load from overload or short circuits. Additionally, when replacing the fuse, the plug will reset the spring and reset the fuse mechanism.
Conclusion
The 5MCLS-3R-B fuse is suitable for use on AC control systems with up to 600V isolation between the hot and neutral circuits. It is designed with an epoxy housing that offers protection from the environment. Additionally, because it is rated for 75°C, it can be used in areas with high ambient temperatures. When the current passes through the fuse element, it produces over-heating and melts the fuse element, which breaks the circuit and stops the current flow. This offers protection to the system by halting the current flow in the event of an overload or short circuit.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
5MCLS-18R-A | Eaton | 2.08 $ | 1000 | MV R RATED FUSE |
5MCLS-18R-B | Eaton | 2.08 $ | 1000 | MV R RATED FUSE |
5MCLS-24R-A | Eaton | 2.08 $ | 1000 | MV R RATED FUSE |
5MCLS-24R-B | Eaton | 2.08 $ | 1000 | MV R RATED FUSE |
5MCLS-2R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-2R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-3R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-3R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-4R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-4R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-12R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-12R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-5R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-5R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-6R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-6R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-9R-A | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
5MCLS-9R-B | Eaton | 0.69 $ | 1000 | MV R RATED FUSE |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL