Allicdata Part #: | 7010.7090.37-ND |
Manufacturer Part#: |
7010.7090.37 |
Price: | $ 0.50 |
Product Category: | Circuit Protection |
Manufacturer: | Schurter Inc. |
Short Description: | FUSE BRD MNT 2A 125VAC/VDC AXIAL |
More Detail: | N/A |
DataSheet: | 7010.7090.37 Datasheet/PDF |
Quantity: | 1000 |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1500 +: | $ 0.45511 |
Response Time: | Fast |
Size / Dimension: | 0.093" Dia x 0.315" L (2.36mm x 8.00mm) |
Color: | -- |
Operating Temperature: | -55°C ~ 85°C |
Approvals: | CSA, UR |
Melting I²t: | 1.1 |
Breaking Capacity @ Rated Voltage: | 300A |
Mounting Type: | Through Hole |
Package / Case: | Cartridge, Non-Standard (Axial) |
Series: | 172322 |
Voltage Rating - DC: | 125V |
Voltage Rating - AC: | 125V |
Current Rating: | 2A |
Fuse Type: | Board Mount (Cartridge Style Excluded) |
Moisture Sensitivity Level (MSL): | -- |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Packaging: | Tape & Reel (TR) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Fuses: 7010.7090.37 Application Field and Working Principle
Fuses are an important component of any electrical system, as they play a critical role in protecting appliances, wiring, and people from incidents like fire and electric shock. Available in a variety of types, sizes, and styles, they can be found in most electrical systems. Of particular note is the widely-used 7010.7090.37 fuse, which is designed for use primarily in residential wiring including lighting circuits, HVAC systems, and electric pool and spa connections. Understanding the working principle, application field, and other details of 7010.7090.37 fuses is essential for proper installation and use.
7010.7090.37 Fuse Working Principle
7010.7090.37 fuses are what are commonly known as conventional fuses and operate on a standard blow fuse principle. The fuse has two contacts—one at either end of a wire, usually copper—and a fuse element which is placed between the contacts. The element is made from a metal alloy with an electrical resistance specific to that model. In operation, the amount of current allowed to flow through the circuit is limited by the electrical resistance of the fuse element.
When an excessive amount of current flows through the circuit, the element heats up and melts. The melted element then disconnects the two contacts and control of current flow is lost. This effectively breaks or "blows" the circuit, preventing a dangerous amount of electricity from passing through and potentially causing a fire or worse. The fuse must then be replaced with a new one of the same ratings before the circuit can be safely resumed.
7010.7090.37 Fuse Application Field
7010.7090.37 fuses are used primarily in residential wiring, including lighting circuit applications, HVAC systems, and electric pool and spa connections. The 7010.7090.37 fuse is designed with a capability of protecting equipment from overloads up to 32 amperes and short circuits up to 80 amperes. This makes them an ideal product for residential applications, as it offers a variety of protection capabilities to suit a wide range of uses.
In addition, these fuses are designed to be low profile, making them easy to install and hide beneath a panel or cover. The low profile design also reduces the chances of the fuse being accidentally removed while the power is still connected. This makes the 7010.7090.37 fuse an ideal choice for electricians and homeowners alike.
7010.7090.37 Fuse Installation and Maintenance Tips
Because 7010.7090.37 fuses are designed to protect against electrical overloads, they must be properly installed and maintained to ensure optimal protection. Here are a few tips to keep in mind when installing and servicing these fuses:
- Always ensure that wire size pairs correctly with the fuse size. If the wire size is too small for the fuse size, it may lead to a possible fire hazard.
- Carefully read and follow the manufacturer\'s instructions as it may differ from the Canadian Electrical Code.
- Always install the fuse in accordance with the manufacturer\'s instructions. This includes installation into the appropriate wire size, voltage and frequency.
- Check regularly for damages including corrosion, water damage or physical damage.
- Never replace a fuse with a different type than what is specified, as doing so may damage the associated equipment.
7010.7090.37 fuses are a widely used safety feature that ensures the protection of homes, businesses, and other structures from fire and electric shock. By understanding the application field, working principle, and installation and maintenance tips associated with this type of fuse, it is possible to safely and effectively install and maintain these fuses for maximum protection.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
SS-701010-NF | Stewart Conn... | 0.76 $ | 130 | CONN MOD JACK 10P10C R/A ... |
7010-0001 | Amulet Techn... | 4.16 $ | 1000 | PEN STYLUS |
7010X5-A | Visual Commu... | 0.36 $ | 1903 | LED YELLOW-GRN CLEAR 1206... |
701008 | Phoenix Cont... | 2.23 $ | 1000 | CONN TERM BLK FEED THRU 6... |
7010X1 | Visual Commu... | 0.0 $ | 1000 | LED RED CLEAR 1206 SMDRed... |
7010X5 | Visual Commu... | 0.0 $ | 1000 | LED GREEN CLEAR 1206 SMDG... |
7010X7 | Visual Commu... | 0.0 $ | 1000 | LED YELLOW CLEAR 1206 SMD... |
7010.1780.12 | Schurter Inc... | 2.83 $ | 1000 | FUSE BOARD MNT 125MA 250V... |
7010.7160.13 | Schurter Inc... | 1.63 $ | 1000 | FUSE BRD MNT 12A 32VAC/VD... |
7010.2450 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 3A 125VAC |
7010.2220 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 500MA 125VAC |
7010.2410 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 1.5A 125VAC |
7010.2440 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 2.5A 125VAC |
7010.2470 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 4A 125VAC |
7010.2480 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 5A 125VAC |
7010.2610 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 6.3A 125VAC |
7010.2630 | Schurter Inc... | 3.26 $ | 1000 | FUSE GLASS 10A 125VAC |
7010.9969.57 | Schurter Inc... | -- | 1000 | FUSE BOARD MOUNT 6.3A 125... |
7010.9963.57 | Schurter Inc... | 0.49 $ | 1000 | FUSE BOARD MOUNT 2A 125VA... |
7010.9962.57 | Schurter Inc... | 0.49 $ | 1000 | FUSE BOARD MOUNT 1.5A 125... |
7010.9966.57 | Schurter Inc... | 0.49 $ | 1000 | FUSE BOARD MOUNT 3.5A 125... |
7010.9961.57 | Schurter Inc... | 0.49 $ | 1000 | FUSE BOARD MOUNT 1A 125VA... |
7010.7070.37 | Schurter Inc... | 0.5 $ | 1000 | FUSE BRD MNT 1A 125VAC/VD... |
7010.7090.37 | Schurter Inc... | 0.5 $ | 1000 | FUSE BRD MNT 2A 125VAC/VD... |
7010.9513.57 | Schurter Inc... | 0.5 $ | 1000 | FUSE BOARD MNT 2A 125VAC/... |
7010.9901.57 | Schurter Inc... | 0.53 $ | 1000 | FUSE BOARD MNT 125MA 125V... |
7010.9903.57 | Schurter Inc... | 0.53 $ | 1000 | FUSE BOARD MNT 375MA 125V... |
7010.9914.57 | Schurter Inc... | 0.53 $ | 1000 | FUSE BRD MNT 7A 63VAC 125... |
7010.7031.47 | Schurter Inc... | 0.6 $ | 1000 | FUSE MSA COLOR CODED |
7010.7051.47 | Schurter Inc... | 0.6 $ | 1000 | FUSE MSA COLOR CODED |
7010.7071.47 | Schurter Inc... | 0.6 $ | 1000 | FUSE MSA COLOR CODED |
7010.9513.03 | Schurter Inc... | 0.61 $ | 1000 | FUSE BOARD MNT 2A 125VAC/... |
7010.9904.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BOARD MNT 500MA 125V... |
7010.9907.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BRD MNT 1.5A 125VAC/... |
7010.9905.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BRD MNT 750MA 125VAC... |
7010.9906.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BRD MNT 1A 125VAC/VD... |
7010.9909.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BRD MNT 2.5A 125VAC/... |
7010.9903.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BOARD MNT 375MA 125V... |
7010.9902.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BOARD MNT 250MA 125V... |
7010.9901.03 | Schurter Inc... | 0.64 $ | 1000 | FUSE BOARD MNT 125MA 125V... |
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 3.15A 125VAC/VDC
FUSE BOARD MNT 350MA 125VAC/VDC
FUSE BRD MNT 2.5A 125VAC/VDC SMD
FUSE BRD MNT 1.6A 125VAC/VDC SMD
FUSE BOARD MNT 1A 250VAC RADIAL