Allicdata Part #: | AG15PC202FB-K2M-ND |
Manufacturer Part#: |
AG15PC202FB-K2M |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Taiyo Yuden |
Short Description: | GDT 2000V 500V THROUGH HOLE |
More Detail: | Gas Discharge Tube 2000V ±500V 2 Pole Through Hol... |
DataSheet: | ![]() |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | AG |
Packaging: | Tape & Reel (TR) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Obsolete |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 2000V |
Impulse Discharge Current (8/20µs): | -- |
Tolerance: | ±500V |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Radial, Box |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT), such as AG15PC202FB-K2M, provide overvoltage protection from electrical noise generated by lightning, electrostatic discharge, or faults in power systems. They use a gas-filled tube between two electrodes and creates a spark gap in the tube which helps to direct energy from the system away from sensitive electronic equipment. This helps limit damage to system components from electrical noise.
The operation of an AG15PC202FB-K2M GDT is relatively simple. The device contains two metal electrodes inside a gas-filled tube. In the axon of the device, the electrodes are connected to a capacitor, and the voltage across the electrodes is monitored by the capacitor. Whenever a voltage spike occurs, the capacitor attempts to discharge its stored energy across the gap between the electrodes. When this happens, the gas inside the tube breaks down, and ionization of the gas occurs, forming an arc between the electrodes.
The main application of AG15PC202FB-K2M GDT’s is to protect electrical systems from power surges and transient voltages caused by lightning strikes. Additionally, they can be used to protect machinery from voltage fluctuations. Furthermore, GDTs are commonly employed in residential and commercial properties to prevent damage from power surges.
AG15PC202FB-K2M GDT’s are designed to absorb a certain amount of energy and current before they fail. This amount, known as the trip energy, is a measure of the current which can flow through the device before it breaks down. This is typically limited to a fraction of the rating of the device, so that it can provide protection to nearby equipment even if the device itself fails. This feature is what makes GDTs desirable for overvoltage protection.
The design of GDTs like the AG15PC202FB-K2M is such that the current which passes through the tube during normal operation is limited to safe levels. The arc which forms in the tube between the two electrodes has very low impedance, and so the current is kept to a minimum. This helps to ensure that any electrical noise or surges are dissipated quickly, and is crucial to the protection provided by GDTs.
AG15PC202FB-K2M GDTs are also designed to be used in a variety of different environments, and are usually rated for use in either outdoor or indoor applications. Outdoor GDTs are designed to withstand direct exposure to the elements, and are therefore usually much tougher and more resistant to damage. Indoor GDTs are designed to be more lightweight and are much easier to install.
In addition to providing overvoltage protection, AG15PC202FB-K2M GDTs can also be used to regulate the voltage of an electrical system. By including a GDT in the circuit, the voltage can be limited to a safe level. This helps prevent system components from being damaged by too much or too little voltage.
In conclusion, the AG15PC202FB-K2M is a specialized Gas Discharge Tube Arrester (GDT) and is used predominantly to provide overvoltage protection. Its design ensures that the current passing through the arc is limited to a safe level, while its ability to absorb energy during a fault makes it an ideal choice for residential and commercial locations. Furthermore, its ability to regulate voltage makes it suitable for use in a variety of different applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
AG15P152FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 1500V 500V THROUGH HO... |
AG15PC122FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 1200V 500V THROUGH HO... |
AG15P202FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 2000V 500V THROUGH HO... |
AG15PC152FS-K2U | Taiyo Yuden | 0.0 $ | 1000 | GDT 1500V 500V THROUGH HO... |
AG15PC252FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 2500V 500V THROUGH HO... |
AG15PC152FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 1500V 500V THROUGH HO... |
AG156W9B | 3M | 25.16 $ | 1000 | AG15.6W9 ANTI-GLARE FILTE... |
AG15P-5 | XP Power | 67.91 $ | 11 | SINGLE O/P, DC-HV DC PCB ... |
AG15PC202FB-K2M | Taiyo Yuden | 0.0 $ | 1000 | GDT 2000V 500V THROUGH HO... |
GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...

GAS DISCHARGE TUBEGas Discharge Tube ...