ATT2BU Allicdata Electronics

ATT2BU Connectors, Interconnects

Allicdata Part #:

ATT2BU-ND

Manufacturer Part#:

ATT2BU

Price: $ 5.59
Product Category:

Connectors, Interconnects

Manufacturer: Amphenol Pcd
Short Description: CONN TERM BLK FEED THRU 12-24AWG
More Detail: Terminal Block Connector 6 Position Feed Through B...
DataSheet: ATT2BU datasheetATT2BU Datasheet/PDF
Quantity: 1000
Moisture Sensitivity Level (MSL): 1 (Unlimited)
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
100 +: $ 5.07780
Stock 1000Can Ship Immediately
$ 5.59
Specifications
Voltage - IEC: 400V
Stripping Length: 9mm
Material Flammability Rating: --
Material - Insulation: Polyamide (PA66), Nylon 6/6
Fuse Type: --
Color: Blue
Features: --
Wire Gauge or Range - mm²: 0.5-2.5mm²
Wire Gauge or Range - AWG: 12-24 AWG
Voltage - UL: 300V
Current - UL: 25A
Series: ATT
Current - IEC: 24A
Termination Style: Screw
Terminal - Width: 6.0mm
Number of Levels: 3
Number of Positions: 6
Disconnect Type: --
Moisture Sensitivity Level (MSL): --
Type: Feed Through
Lead Free Status / RoHS Status: --
Part Status: Active
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Terminal Blocks - Din Rail, Channel are a type of electrical connection unit used for establishing electrical connections between two components of an electronic device. A basic terminal block consists of two parts: an insulating base (which is usually made from plastic) and a pair of conductors or contacts, which are typically made from copper. The two parts are separated by an insulating layer between them. The two parts are then connected to a power source, usually through a terminal strip, and the electrical connection is made when a conductor is attached to each contact. The terminal blocks are designed to provide an efficient and accurate power transfer, and the contact pairs are usually spaced apart so that the desired current level is transmitted through them.

ATT2BU terminal blocks are a type of Din Rail, Channel-type terminal blocks. As with other types, their primary purpose is to provide an efficient and accurate power transfer. However, they provide a few additional features that make them ideal for many applications. Namely, their shape makes them particularly suitable for applications involving high current and voltage levels. The ATT2BU terminal blocks are designed so that they can accommodate large currents, up to 200A in some cases. They also feature a two-position design, allowing them to support multiple conductors at the same time.

When it comes to their working principle, ATT2BU terminal blocks consist of two parts: the base and the contacts. The base is usually made of a plastic material and carries a layer of insulating material in between the two contacts. As mentioned earlier, the contacts are typically made from copper, allowing for efficient power transfer between the two contacts. The contacts also have an encasing layer that ensures the contacts are securely mounted to the base. The contacts of the ATT2BU terminal blocks are designed to snap into the base, and they can be attached or detached easily as needed.

To make a connection, the contacts of the ATT2BU terminal blocks would need to be attached to the two components being connected. Most of the time, this is done with screws. The screws would penetrate the plastic base of the terminal blocks and allow the contacts to be securely attached to the components. Once the contacts are attached, the power between the two components is then established. This is done simply by the contacts being loosely connected, allowing for a safe and accurate power transfer.

ATT2BU terminal blocks are ideal for a variety of applications, mainly when high currents and voltages are required. Their two-position design allows multiple contacts to be connected to one terminal block, making them perfect for applications which involve energy-intensive components. Furthermore, their screw-on design ensures components are securely connected, and their insulation ensures no electrical current is safely transmitted between them.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "ATT2" Included word is 16
Part Number Manufacturer Price Quantity Description
ATT2CL12 Amphenol Pcd 0.36 $ 1000 SHORT LINK COMB INSUL DIN...
ATT2CL13 Amphenol Pcd 0.53 $ 1000 SHORT LINK COMB INSUL DIN...
ATT2CL14 Amphenol Pcd 0.7 $ 1000 SHORT LINK COMB INSUL DIN...
ATT2SL12 Amphenol Pcd 0.76 $ 1000 SHORTING LINK PRE-ASSY 2P...
ATT2MT1 Amphenol Pcd 0.34 $ 1000 MARKING TAGS DIN RAIL 6MM...
ATT2SL13 Amphenol Pcd 1.13 $ 1000 SHORTING LINK PRE-ASSY 3P...
ATT2SL14 Amphenol Pcd 1.44 $ 1000 SHORTING LINK PRE-ASSY 4P...
ATT2CL110 Amphenol Pcd 1.51 $ 1000 SHORT LINK COMB INSUL DIN...
ATT2SL110 Amphenol Pcd 3.42 $ 1000 SHORTING LINK PRE-ASSY 10...
ATT2 Amphenol Pcd 5.59 $ 1000 CONN TERM BLK FEED THRU 1...
ATT2BK Amphenol Pcd 5.59 $ 1000 CONN TERM BLK FEED THRU 1...
ATT2BU Amphenol Pcd 5.59 $ 1000 CONN TERM BLK FEED THRU 1...
ATT2R Amphenol Pcd 5.59 $ 1000 CONN TERM BLK FEED THRU 1...
ATT2Y Amphenol Pcd 5.59 $ 1000 CONN TERM BLK FEED THRU 1...
ATT2TS Amphenol Pcd 0.43 $ 1000 TERM BLOCK RAIL 6MM TEST ...
ATT2EP Amphenol Pcd 0.69 $ 1000 TERM BLOCK RAIL 6MM END P...
Latest Products
3248166

TERM BLK MICRO FEED THRU 8POSTerminal Bl...

3248166 Allicdata Electronics
3005329

CONN TERM BLK FEED THRU 14-26AWGTerminal...

3005329 Allicdata Electronics
1013700000

CONN TERM BLK DISCONN 12-26AWGTerminal B...

1013700000 Allicdata Electronics
1313360000

CONN TERM BLK FEED THRU 12-26AWGTerminal...

1313360000 Allicdata Electronics
2749880

CONN TERM BLK FEED THRU 2-20 AWGTerminal...

2749880 Allicdata Electronics
3005138

CONN TERM BLK DISCONNECT 6-24AWGTerminal...

3005138 Allicdata Electronics