Allicdata Part #: | 495-2632-ND |
Manufacturer Part#: |
B88069X2930C102 |
Price: | $ 1.36 |
Product Category: | Circuit Protection |
Manufacturer: | EPCOS (TDK) |
Short Description: | GDT 230V 20% 5KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 230V 5000A (5kA) ±20% 2 Pole Th... |
DataSheet: | B88069X2930C102 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 1.22850 |
5 +: | $ 1.17180 |
10 +: | $ 1.11321 |
50 +: | $ 0.89838 |
100 +: | $ 0.76167 |
250 +: | $ 0.74214 |
500 +: | $ 0.62496 |
1000 +: | $ 0.55661 |
5000 +: | $ 0.48825 |
Series: | M51-A230X |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 230V |
Impulse Discharge Current (8/20µs): | 5000A (5kA) |
Tolerance: | ±20% |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are electrical components that are designed to protect electrical systems, components, and personnel from damage caused by lightning strikes or other sources of overvoltage. The B88069X2930C102 is an example of a GDT. In this article we will discuss the application field and working principle of this device.
The B88069X2930C102 Gas Discharge Tube Arrester is designed to provide overvoltage protection by discharge of high-voltage energy in short pulses at a low average current. It employs gas discharge tube technology to protect against lightning surges and fast transients, and uses Varistors as the main protection element. The device works according to the following principle: Its internal Varistors have a certain cut-off voltage rating, which acts as a threshold voltage below which the device does not turn on. When the device is exposed to an input voltage that exceeds this cutoff voltage, it activates and begins to discharge, dissipating the excess voltage and protecting the downstream components from damage.
The B88069X2930C102 Gas Discharge Tube Arrester is used in a variety of application fields, such as telecommunication networks, power lines, and industrial plants. In telecommunication networks, it can be used to protect system components from damage caused by lightning strikes, direct strikes, and other environmental effects. In power lines, it can be used to protect against surges caused by switching events, and in industrial plants, it can be used to provide surge protection for sensitive electronic equipment. It is also used in automotive systems, to protect against voltage transients caused by switches and relays, and in HVAC systems, to provide surge protection for sensors and controls.
In order to ensure proper and reliable operation, it is important to take into account the device’s power load requirements and to select the appropriate type for the application. For example, a device intended for automotive applications should be able to handle higher power surges than a device intended for telecommunications use. The device should also be installed in a way that it is not exposed to environmental conditions that could degrade its performance or reliability. Moreover, the device should be connected in series with the protected load in order to provide the most effective protection.
In summary, the B88069X2930C102 Gas Discharge Tube Arrester is a reliable and versatile device that can be used in a variety of application fields to provide effective surge protection. It is important to take into account the device’s power load requirements in order to ensure proper and reliable operation. Additionally, the device should be installed in a way that it is not exposed to environmental conditions that could degrade its performance or reliability, and should be placed in series with the protected load in order to provide the most comprehensive protection.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
B88069X1150S102 | EPCOS (TDK) | 0.0 $ | 1000 | EC 170XGas Discharge Tube... |
B88069X2351C102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
B88069X3340S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS1X-1Gas Discharge Tube ... |
B88069X3640C502 | EPCOS (TDK) | 0.0 $ | 1000 | FS1X-1Gas Discharge Tube ... |
B88069X3690S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS06X-1NGas Discharge Tub... |
B88069X3831B502 | EPCOS (TDK) | 0.0 $ | 1000 | ER6-A230XGas Discharge Tu... |
B88069X0400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS04X-1JMGas Discharge Tu... |
B88069X4251S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 4000V 20% 2KA THROUGH... |
B88069X4420C201 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 2200V 20% 20KA THREAD... |
B88069X4521B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 250V 20% 5KA T/H FAIL... |
B88069X4660C102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 230V 20% 5KA THROUGH ... |
B88069X4941B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KA T/H FAIL... |
B88069X5111B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
B88069X5400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS08X-1JMGas Discharge Tu... |
B88069X5460B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 230V 20% 5KAGas Disch... |
B88069X5571B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 250V 20% 5KA FAIL SHO... |
B88069X6331S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V THROUGH HOLEGas ... |
B88069X1080T502 | EPCOS (TDK) | 0.0 $ | 1000 | EC 150XGGas Discharge Tub... |
B88069X3320T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3350T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 1000V THROUGH HOLEGas... |
B88069X3450T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 1000V THROUGH HOLEGas... |
B88069X3560T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3630T502 | EPCOS (TDK) | 0.0 $ | 1000 | FS03X-1GGas Discharge Tub... |
B88069X3660T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 600V THROUGH HOLEGas ... |
B88069X3790T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X0410T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 400V THROUGH HOLEGas ... |
B88069X5980T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 850V THROUGH HOLEGas ... |
B88069X8821B502 | EPCOS (TDK) | 0.0 $ | 1000 | 2 ELECT / 3600VGas Discha... |
B88069X0240S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X1240B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X1480S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X2490C502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X3540S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X3780B162 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X5311S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X5311T502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6611B502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6650C253 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6920B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...