Allicdata Part #: | 495-4373-ND |
Manufacturer Part#: |
B88069X7460B102 |
Price: | $ 2.91 |
Product Category: | Circuit Protection |
Manufacturer: | EPCOS (TDK) |
Short Description: | GDT 400V 25% 20KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 400V 20000A (20kA) ±25% 3 Pole ... |
DataSheet: | B88069X7460B102 Datasheet/PDF |
Quantity: | 148 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 2.64600 |
5 +: | $ 2.55780 |
10 +: | $ 2.46960 |
50 +: | $ 1.94040 |
100 +: | $ 1.58760 |
250 +: | $ 1.54350 |
500 +: | $ 1.32300 |
1000 +: | $ 1.23480 |
5000 +: | $ 1.10250 |
Series: | T63 |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 400V |
Impulse Discharge Current (8/20µs): | 20000A (20kA) |
Tolerance: | ±25% |
Number of Poles: | 3 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder, 3 Lead (Radial Bend) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Comprehensive protectio n plays an essential role in limiting the damage caused by overvoltage and overcurrent events as electricity grids grow more and more complex. One measure used for this purpose is a Gas Discharge Tube Arresters (GDT) such as the B88069X7460B102. As an example of the surge suppression category within the arrester family, this device carries out the important function of diverting and grounding fault energy during such incidents. This article will explain the application field and working principle of the B88069X7460B102.
The GDT component comes in a metal protection tube encasing, creating an excellent visual appearance. Its primary purpose is to provide overvoltage protection, and it is most commonly used to protect simple AC/DC circuits from overvoltage. These GDTs are available in a range of sizes and are generally utilized in equipment and systems related to national defense, electronic communications, computer and control, anti-submarine navigation, aerospace and medical equipment. They can also be installed between the lightning protection unit and the main circuit.
A GDT is made up of a central cylinder filled with different types of gas, such as a vacuum, or a combination of air, nitrogen, and other gases. It also features two electrodes connected to the external circuitry, and both electrodes are metal contacts that conduct electricity when activated. When the GDT is subjected to a high voltage, the ions in the gas become excited and create an electric arc. This is the principle behind the GDT working – ions in the gas are already in a state of equilibrium, so when the voltage applied to the GDT exceeds a certain level, the electrons become excited and generate an electric discharge. The electric arc is then conducted through the two electrodes and creates a ground fault.
The B88069X7460B102 is equipped with a pressure insensitive gas chamber, allowing it to withstand higher surge stress over a wide range of operating temperatures. This is due to its configurable pressure range which can be adjusted to meet specific requirements. For example, it can be configured to ensure adequate basic protection for components at higher temperatures, or at a lower temperature setting to protect against high voltage transient surges.
The B88069X7460B102 also has a built-in varistor for improved overvoltage protection. A varistor is a component connected to the system’s power supply that is designed to absorb energy. The varistor allows for higher current levels and improved reactivity, and also offers protection against high voltages. It is highly efficient and provides effective overvoltage protection.
Apart from its advanced protection characteristics, the B88069X7460B102 GDT also offers wide temperature stability. This ensures dependable protection, even under extreme temperature changes and rapidly changing surge patterns. Additionally, its surge-resistant construction guarantees a long service life, making it one of the most reliable surge protection components available.
In summary, the B88069X7460B102 GDT is a comprehensive surge protection component designed for AC/DC circuits. It is equipped with a pressure insensitive gas chamber and a built-in varistor, which together form a powerful overvoltage protection system. This system is further enhanced by its wide temperature stability, making it an ideal choice for applications that require reliable surge suppression.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
B88069X1150S102 | EPCOS (TDK) | 0.0 $ | 1000 | EC 170XGas Discharge Tube... |
B88069X2351C102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
B88069X3340S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS1X-1Gas Discharge Tube ... |
B88069X3640C502 | EPCOS (TDK) | 0.0 $ | 1000 | FS1X-1Gas Discharge Tube ... |
B88069X3690S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS06X-1NGas Discharge Tub... |
B88069X3831B502 | EPCOS (TDK) | 0.0 $ | 1000 | ER6-A230XGas Discharge Tu... |
B88069X0400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS04X-1JMGas Discharge Tu... |
B88069X4251S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 4000V 20% 2KA THROUGH... |
B88069X4420C201 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 2200V 20% 20KA THREAD... |
B88069X4521B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 250V 20% 5KA T/H FAIL... |
B88069X4660C102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 230V 20% 5KA THROUGH ... |
B88069X4941B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KA T/H FAIL... |
B88069X5111B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
B88069X5400S102 | EPCOS (TDK) | 0.0 $ | 1000 | FS08X-1JMGas Discharge Tu... |
B88069X5460B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 230V 20% 5KAGas Disch... |
B88069X5571B502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 250V 20% 5KA FAIL SHO... |
B88069X6331S102 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 350V THROUGH HOLEGas ... |
B88069X1080T502 | EPCOS (TDK) | 0.0 $ | 1000 | EC 150XGGas Discharge Tub... |
B88069X3320T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3350T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 1000V THROUGH HOLEGas... |
B88069X3450T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 1000V THROUGH HOLEGas... |
B88069X3560T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X3630T502 | EPCOS (TDK) | 0.0 $ | 1000 | FS03X-1GGas Discharge Tub... |
B88069X3660T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 600V THROUGH HOLEGas ... |
B88069X3790T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 800V THROUGH HOLEGas ... |
B88069X0410T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 400V THROUGH HOLEGas ... |
B88069X5980T502 | EPCOS (TDK) | 0.0 $ | 1000 | GDT 850V THROUGH HOLEGas ... |
B88069X8821B502 | EPCOS (TDK) | 0.0 $ | 1000 | 2 ELECT / 3600VGas Discha... |
B88069X0240S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X1240B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X1480S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X2490C502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X3540S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X3780B162 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X5311S102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X5311T502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6611B502 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6650C253 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
B88069X6920B102 | EPCOS (TDK) | 0.0 $ | 1000 | GAS DISCHARGE TUBEGas Dis... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...