Allicdata Part #: | CG5400LTR-ND |
Manufacturer Part#: |
CG5400LTR |
Price: | $ 0.92 |
Product Category: | Circuit Protection |
Manufacturer: | Littelfuse Inc. |
Short Description: | GDT 400V 5KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 400V 5000A (5kA) 2 Pole Throug... |
DataSheet: | CG5400LTR Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.83222 |
Series: | CG5 |
Packaging: | Tape & Reel (TR) |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 400V |
Impulse Discharge Current (8/20µs): | 5000A (5kA) |
Tolerance: | -- |
Number of Poles: | 2 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT) are an important tool for the protection of electrical networks from lightning or other over-voltage damage. GDTs work by providing an impedance in the high-voltage circuit, and they create an electric shield around the protected area, preventing the passage of dangerous voltages. The CG5400LTR is an advanced lightning surge protection device, developed to provide high levels of protection in the most difficult electrical circuits and environments.
At the heart of the CG5400LTR is a metal-oxide varistor (MOV) which provides the only reliable means of protecting against severe over-voltage conditions. The MOV has a high-impedance material which absorbs the energy from the excessive current or voltage, dissipating it safely and protecting the circuit from damage. By incorporating this MOV in the CG5400LTR, surges can be rapidly dispersed or even prevented from occurring in the first place. The CG5400LTR is further protected by a gas discharge tube (GDT) arrester which can provide additional levels of protection, such as the limitation of peak voltage levels.
The CG5400LTR is a compact unit with a small footprint and is designed for use in a variety of applications. Its flexible design makes it suitable for use in a variety of environments, including industrial, commercial, and residential situations. It can be used to protect a wide range of electrical equipment, including computers, telecommunications equipment, motors, and transformers. The device is also suitable for direct mounted applications as well as point-of-use applications, such as with wiring in walls or ceilings.
The CG5400LTR is designed for a wide range of applications, but the most common application is in sensitive electronic equipment such as computers and telecommunications equipment. In this case, the device acts as a lightning arrester, preventing high voltage transients from entering and damaging the equipment. When lightning strikes, the MOV dissipates the energy of the current and allows the GDT to limit the peak voltage. In most cases, this prevents the device from damaging the equipment, but in rare cases, the MOV may become overloaded and allow the spike to pass through, which could cause damage.
The CG5400LTR is also suitable for use in circuits where a slight voltage over-shoot is expected. This could be due to a switching action in the circuit, or when a motor is started and draws high peak current. In this case, the MOV of the CG5400LTR will absorb the extra energy and prevent the potential damage from occurring.
The GDT of the CG5400LTR is rated at 10,000A for 5 to 500 µs, and 5,000A for 8/20 µs surges. This means that the device is capable of withstanding very high levels of voltage and current, and can provide excellent protection against electrical surges and transients. In addition to it\'s high surge rating, the CG5400LTR is also able to reduce the total amount of sag and swell, thus providing a more consistent voltage supply.
The CG5400LTR is a cost-effective solution for over-voltage protection, and is suitable for use in a wide range of applications. By employing an MOV and a GDT, it can provide high levels of protection and ensure reliable operation in even the toughest electrical environments. The CG5400LTR ensures excellent protection against lightning strikes, as well as other high-voltage transients, and is a reliable and cost-effective way to protect sensitive electrical equipment.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CG5470L | Littelfuse I... | 0.88 $ | 1000 | GDT 470V 5KA THROUGH HOLE... |
CG5400LTR | Littelfuse I... | 0.92 $ | 1000 | GDT 400V 5KA THROUGH HOLE... |
CG5470LNF | Littelfuse I... | 1.19 $ | 1000 | GDT 470V 5KA 470V W/ FAIL... |
CG5400L-02 | Littelfuse I... | 1.23 $ | 1000 | GDT 400V 5KA THROUGH HOLE... |
CG5470LS | Littelfuse I... | 2.23 $ | 1000 | S.A.STANDARD LEADED.470V ... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...