Allicdata Part #: | CRD4110-25-ND |
Manufacturer Part#: |
CRD4110-25 |
Price: | $ 172.01 |
Product Category: | Sensors, Transducers |
Manufacturer: | CR Magnetics Inc. |
Short Description: | SENSOR CURRENT XFMR 25A AC |
More Detail: | Current Sensor 25A 1 Channel Transformer w/Conditi... |
DataSheet: | CRD4110-25 Datasheet/PDF |
Quantity: | 1000 |
1 +: | $ 156.37200 |
Series: | CRD4100 |
Packaging: | Bulk |
Part Status: | Active |
For Measuring: | AC |
Sensor Type: | Transformer w/Conditioning |
Current - Sensing: | 25A |
Number of Channels: | 1 |
Output: | RS485 |
Sensitivity: | -- |
Frequency: | 20Hz ~ 5kHz |
Linearity: | -- |
Accuracy: | ±0.5% |
Voltage - Supply: | 24V |
Response Time: | 250ms |
Current - Supply (Max): | 30mA |
Operating Temperature: | 0°C ~ 60°C |
Polarization: | Bidirectional |
Mounting Type: | DIN Rail, Panel |
Package / Case: | Module |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are essential components for measuring and controlling the flow of electricity in electrical components. In particular, they are used in applications such as motor protection, overload and short-circuit protection, motor starter protection, and power factor monitoring. The CRD4110-25 current transducer is a high-performance, cost-effective current transformer designed to measure currents ranging from 0.1 to 25 Amps.
Applications
The CRD4110-25 current transducer is designed to measure electrical current and provide the necessary outputs for a variety of applications, including motor protection, overload and short-circuit protection, motor starter protection, and power factor monitoring.
In particular, it can be used to protect motors by detecting current fluctuations. If current fluctuations exceed a pre-set limit, the normal operation is interrupted and an alarm signal is sent. This prevents overvoltages or overcurrents from occurring, helping to ensure the safe operation of the motor. Additionally, it can be used to monitor short-circuits in a power system to maintain system reliability and prevent outages. It can also be used to monitor and control motor starters, to ensure that the start-up current does not exceed the design current.
The CRD4110-25 is also useful for monitoring power factor. By monitoring power factor, it is possible to ensure the power factor is maintained within a specified range. This helps to improve the efficiency of the system, reduce emissions, and conserve energy.
Working Principle
The CRD4110-25 current transducer is a three-phase sensing device that monitors the current flowing through a three-phase system. It consists of three CTs (current transformers), each of which is designed to measure current in one phase. The output of the CT is proportional to the current in the phase and generates an alternating voltage output signal. These signals are then amplified and rectified to produce a voltage or current output signal.
The CTs are also equipped with a core that produces the output voltage. The magnetic field produced by the current in the phase is coupled to the core, inducing a voltage. This voltage is then rectified and amplified, resulting in a voltage output that is proportional to the current in the phase.
The output from the CTs is integrated and processed by a CPU and the relevant parameters are sent to the output. The output can then be used to control and monitor the power system, helping to ensure it operates safely and efficiently.
Conclusion
The CRD4110-25 current transducer is a high-performance, cost-effective transducer designed to measure currents ranging from 0.1 to 25 Amps. It is designed to measure electrical current and provide the necessary outputs for a variety of applications, including motor protection, overload and short-circuit protection, motor starter protection, and power factor monitoring. It consists of three CTs, each of which is designed to measure current in one phase, and the output is integrated and processed by a CPU. The output can then be used to control and monitor the power system, helping to ensure it operates safely and efficiently.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CRD4110-25 | CR Magnetics... | 172.01 $ | 1000 | SENSOR CURRENT XFMR 25A A... |
CRD4110-15 | CR Magnetics... | 172.01 $ | 1000 | SENSOR CURRENT XFMR 15A A... |
CRD4110-5 | CR Magnetics... | 172.01 $ | 1000 | SENSOR CURRENT XFMR 5A AC... |
CRD4110-1 | CR Magnetics... | 172.01 $ | 1000 | SENSOR CURRENT XFMR 1A AC... |
CRD4150-5 | CR Magnetics... | 220.91 $ | 1000 | SENSOR CURRENT XFMR 5A AC... |
CRD4150-1 | CR Magnetics... | 220.91 $ | 1000 | SENSOR CURRENT XFMR 1A AC... |
CRD4150-15 | CR Magnetics... | 220.91 $ | 1000 | SENSOR CURRENT XFMR 15A A... |
CRD4150-25 | CR Magnetics... | 220.91 $ | 1000 | SENSOR CURRENT XFMR 25A A... |
CRD4170-1 | CR Magnetics... | 293.51 $ | 1000 | SENSOR CURRENT XFMR 1A AC... |
CRD4170-15 | CR Magnetics... | 293.51 $ | 1000 | SENSOR CURRENT XFMR 15A A... |
CRD4170-25 | CR Magnetics... | 293.51 $ | 1000 | SENSOR CURRENT XFMR 25A A... |
CRD4170-5 | CR Magnetics... | 293.51 $ | 1000 | SENSOR CURRENT XFMR 5A AC... |
CRD485-232 | CR Magnetics... | 23.51 $ | 1000 | CONVERTER ACCESSORY |
CRD4510-300 | CR Magnetics... | 172.01 $ | 1000 | TRANSDCR VLT AC RS485 0-3... |
CRD4510-150 | CR Magnetics... | 172.01 $ | 1000 | TRANSDCR VLT AC RS485 0-1... |
CRD4550-150 | CR Magnetics... | 220.91 $ | 1000 | TRANSDCR VLT AC RS485 0-1... |
CRD4550-300 | CR Magnetics... | 220.91 $ | 1000 | TRANSDCR VLT AC RS485 0-3... |
CRD4570-150 | CR Magnetics... | 293.51 $ | 1000 | TRANSDCR VLT AC RS485 0-1... |
CRD4570-300 | CR Magnetics... | 293.51 $ | 1000 | TRANSDCR VLT AC RS485 0-3... |
CRD48L10-4IN4OUT | Cirrus Logic... | 306.6 $ | 3 | EVAL BRD CHAS REF BOARDCS... |
CRD48L11 | Cirrus Logic... | 546.0 $ | 12 | EVAL REFERENCE BOARD CS48... |
CRD4525-Q1 | Cirrus Logic... | 528.36 $ | 5 | REFERENCE BOARD FOR CS452... |
CRD44600-PH-FB | Cirrus Logic... | 528.44 $ | 1 | EVAL BOARD FOR CS44600CS4... |
CRD4412A | Cirrus Logic... | 0.0 $ | 1000 | REFERENCE DESIGN FOR CS44... |
CRD42L52 | Cirrus Logic... | 265.44 $ | 1 | REFERENCE DESIGN FOR CS42... |
CRD48DV2-USB | Cirrus Logic... | 175.0 $ | 1000 | EVAL BD 2CH 32BIT FF AUDI... |
CRD42L51 | Cirrus Logic... | 196.88 $ | 1000 | REF BOARD LV STEREO CODEC... |
CRD49834 | Cirrus Logic... | 235.2 $ | 1000 | BOARD EVAL FOR CS49834CS4... |
CRD497024-DC53 | Cirrus Logic... | 294.0 $ | 1000 | EVAL BOARD DUAL DSPEvalua... |
CRD42528 | Cirrus Logic... | 453.6 $ | 1000 | REF DESIGN FOR CS42528 CS... |
CRD4210 | Cirrus Logic... | 0.0 $ | 1000 | REFERENCE DESIGN FOR CS42... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...
SENSOR CURRENT XFMR 5A ACCurrent Sensor ...
SENSOR CURRENT HALL 15A AC/DCCurrent Sen...
3 PIECE KIT SENSOR CURRENT HALLCurrent S...
PACT RCP-4000A-1A-D190Current Sensor 100...
SENSOR CURRENT HALL 30A DCCurrent Sensor...