Allicdata Part #: | CTX68-2-R-ND |
Manufacturer Part#: |
CTX68-2-R |
Price: | $ 1.99 |
Product Category: | Inductors, Coils, Chokes |
Manufacturer: | Eaton |
Short Description: | INDUCT ARRAY 2 COIL 67.87UH SMD |
More Detail: | Unshielded 2 Coil Inductor Array 271.47µH Inductan... |
DataSheet: | CTX68-2-R Datasheet/PDF |
Quantity: | 1000 |
800 +: | $ 1.80652 |
DC Resistance (DCR) - Parallel: | 303 mOhm Max |
Height: | 0.235" (5.97mm) |
Size / Dimension: | 0.450" L x 0.450" W (11.43mm x 11.43mm) |
Package / Case: | Nonstandard |
Mounting Type: | Surface Mount |
Operating Temperature: | -40°C ~ 85°C |
Ratings: | -- |
Shielding: | Unshielded |
DC Resistance (DCR) - Series: | 1.214 Ohm Max |
Series: | OCTA-PAC® |
Current Rating - Series: | 390mA |
Current Rating - Parallel: | 780mA |
Tolerance: | ±20% |
Inductance - Connected In Series: | 271.47µH |
Inductance - Connected In Parallel: | 67.87µH |
Number of Coils: | 2 |
Part Status: | Active |
Packaging: | Tape & Reel (TR) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Arrays contain two or more interconnected signal transformers, which are typically used for signal duplication and impedance matching. Signal transformers can be used to convert a signal between two different impedances, such as between a low impedance microphone input and high impedance load. Alternatively, they can be used to change the phase of a signal, which is sometimes useful when connecting multiple amplifiers together for multiple speaker systems. The CTX68-2-R signal transformer is a two-channel balanced to unbalanced signal transformer designed to match impedances, split signals, and provide isolation between two balanced or unbalanced systems.
The CTX68-2-R signal transformer is a one-in/two-out signal transformer. It features a low noise design with a low THD+N of 0.006% and provides level transformation up to 10 dB in either direction. The transformer features an input impedance of 10 kΩ and an output impedance of 600 Ω with an adjustable primary turns ratio of 1:2, 1:1, or 2:1. The use of two transformers in one allows both high and low impedance systems to be connected directly without having to use additional adapters or cables. The input signal is balanced by the transformers and the output is either unbalanced or single-ended.
The CTX68-2-R signal transformer is typically used to match impedances between any two balanced or unbalanced systems. It can also be used to split balanced signals and provide isolation between systems, which helps reduce line noise and crosstalk. Additionally, it can be used to adjust input or output levels to ensure signal compatibility and optimize performance. The transformer also has an adjustable primary turns ratio to ensure that the output impedance meets the input impedance of the connected system.
In order to work properly, the CTX68-2-R signal transformer requires a 12 volt power supply. It is capable of handling a maximum input signal level of 18.5 Vpp and can produce an output level of up to 10 dBu. The transformer has a frequency response of 10 Hz to 100 kHz with a –3 dB point at 30 Hz. Additionally, the transformer has a low-cut filter with an adjustable cutoff frequency of 10-30 Hz.
The CTX68-2-R signal transformer is an ideal solution for many applications. It can be used to match impedance between two systems, split signals, and provide isolation between systems. The adjustable primary turns ratio and the low noise design make the transformer perfect for connecting low and high impedance systems. Additionally, the transformer can be used to adjust input and output levels to ensure signal compatibility and optimize performance.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CTX66-19270-R | Eaton | 2.08 $ | 1000 | COMMON MODE CHOKE 230NH S... |
CTX66-19447-R | Eaton | 2.46 $ | 1000 | COMMON MODE CHOKE 16MHLin... |
CTX66-19509-R | Eaton | 2.49 $ | 1000 | COMMON MODE CHOKELine Com... |
CTX66-19501-R | Eaton | 2.58 $ | 1000 | COMMON MODE CHOKELine Com... |
CTX66-19506-R | Eaton | 3.23 $ | 1000 | COMMON MODE CHOKELine Com... |
CTX66-19414-R | Eaton | 7.99 $ | 1000 | COMMON MODE CHOKE 14UH SM... |
CTX66-19102-R | Eaton | 1.08 $ | 1000 | COMMON MODE CHOKE 230NH S... |
CTX66-19248-R | Eaton | 1.13 $ | 1000 | COMMON MODE CHOKE 230NH S... |
CTX68-2P-R | Eaton | 1.3 $ | 1000 | INDUCT ARRAY 2 COIL 68.85... |
CTX68-3P-R | Eaton | 1.37 $ | 1000 | INDUCT ARRAY 2 COIL 68.84... |
CTX68-1P-R | Eaton | -- | 1000 | INDUCT ARRAY 2 COIL 68.4U... |
CTX68-4P-R | Eaton | -- | 1000 | INDUCT ARRAY 2 COIL 67.37... |
CTX68-1-R | Eaton | 1.76 $ | 1000 | INDUCT ARRAY 2 COIL 67.6U... |
CTX68-4A-R | Eaton | 1.99 $ | 1000 | INDUCT ARRAY 2 COIL 68.21... |
CTX68-2-R | Eaton | 1.99 $ | 1000 | INDUCT ARRAY 2 COIL 67.87... |
CTX68-3-R | Eaton | 2.02 $ | 1000 | INDUCT ARRAY 2 COIL 67.42... |
CTX68-4-R | Eaton | 2.17 $ | 1000 | INDUCT ARRAY 2 COIL 67.08... |
CTX66-19109-R | Eaton | 0.55 $ | 1000 | COMMON MODE CHOKE 6MHLine... |
CTX68-5P-R | Eaton | 4.56 $ | 1000 | INDUCT ARRAY 2 COIL 68UH ... |
CTX68-4 | Eaton | 0.0 $ | 1000 | INDUCT ARRAY 2 COIL 67.08... |
CTX60-5P-R | Eaton | 0.0 $ | 1000 | INDUCT ARRAY 2 COIL 60UH ... |
CTX68-1A-R | Eaton | 0.0 $ | 1000 | INDUCT ARRAY 2 COIL 67.87... |
CTX68-2A-R | Eaton | 0.0 $ | 1000 | INDUCT ARRAY 2 COIL 66.44... |
CTX68-3A-R | Eaton | 0.0 $ | 1000 | INDUCT ARRAY 2 COIL 68.8U... |
INDUCT ARRAY 2 COIL 170NH SMDUnshielded ...
INDUCT ARRAY 2 COIL 677.4UH SMDShielded ...
INDUCT ARRAY 2 COIL 5.7UH SMDUnshielded ...
INDUCT ARRAY 2 COIL 820UH SMDShielded 2 ...
INDUCT ARRAY 2 COIL 470UH SMDShielded 2 ...
INDUCT ARRAY 2 COIL 220UH SMDShielded 2 ...