Allicdata Part #: | D7524.13.05-ND |
Manufacturer Part#: |
D7524.13.05 |
Price: | $ 40.29 |
Product Category: | Circuit Protection |
Manufacturer: | General Cable/Carol Brand |
Short Description: | PLUG-IT GFCI - CLAMSHELL |
More Detail: | N/A |
DataSheet: | D7524.13.05 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
6 +: | $ 36.62080 |
Series: | Plug-It® |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Type: | Plug with Receptacle |
Moisture Sensitivity Level (MSL): | -- |
Specifications: | 125V |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Ground fault circuit interrupters (GFCI\'s) are safety devices used in electrical circuits to detect a ground fault, or a disturbance in the balance between current going to and coming from electrical loads. They are designed to limit the amount of damage to devices caused by a ground fault. D7524.13.05 is an example of a GFCI and it is used in a wide variety of applications and it is important to understand how it works.
Application field
D7524.13.05 is commonly used in residential and commercial applications such as kitchens, wet bars, bathrooms, and laundry rooms to protect against electrical shock hazards in the event of a ground fault or power failure. It is also used in industrial applications such as manufacturing, food processing, and materials handling to prevent electric shock hazards in the event of a ground fault or power interruption.
It can also be used in conjunction with surge protectors to reduce the amount of electricity going to electrical components in the event of a surge of current. This helps protect delicate electronic components from damage caused by sudden spikes in power.
Working principle
The working principle of the D7524.13.05 GFCI is quite simple. When a ground fault occurs, the device detects a difference in current between the live wire and the ground wire. When the difference is detected, the GFCI interrupts the flow of electricity by breaking the circuit. This prevents any further damage and eliminates the risk of electric shock.
The D7524.13.05 GFCI also has a secondary safety feature that will trip if the RMS voltage increases or decreases too much. This is used in the event of a power failure or surge in order to protect sensitive electronic components.
Furthermore, the D7524.13.05 GFCI is designed to be “fail safe” so that when it trips, it cannot be reset until the issue causing the trip has been corrected. This ensures that the circuit will remain interrupted until the source of the problem has been fixed, thus eliminating any further risk of electric shock.
In summary, the D7524.13.05 GFCI is a useful and important safety device that helps protect people and their property from electric shocks and other hazards associated with electrical systems. It is used in a variety of residential, commercial, and industrial applications and should be employed wherever electricity is present.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
D7524.13.05 | General Cabl... | 40.29 $ | 1000 | PLUG-IT GFCI - CLAMSHELL |
PLUG GFCI 120VAC 15/20A AUTORST
CORD GFCI 120VAC 25' YEL TRITAP
CORD GFCI 120VAC 25' YEL SNG
CORD GFCI 120VAC 2' YEL TRITAP
CORD GFCI 120VAC 2' YEL SNG TAP
PLUG GFCI 120VAC 15A MAN RST