H3Y-4 AC200-230 60S Allicdata Electronics
Allicdata Part #:

H3Y-4AC200-23060S-ND

Manufacturer Part#:

H3Y-4 AC200-230 60S

Price: $ 76.08
Product Category:

Industrial Controls

Manufacturer: Omron Automation and Safety
Short Description: RELAY TIME DELAY 60SEC 3A 250V
More Detail: Off-Delay, On-Delay Time Delay Relay 4PDT (4 Form ...
DataSheet: H3Y-4 AC200-230 60S datasheetH3Y-4 AC200-230 60S Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1 +: $ 69.15510
Stock 1000Can Ship Immediately
$ 76.08
Specifications
Series: H3Y
Part Status: Active
Lead Free Status / RoHS Status: --
Relay Type: Mechanical Relay
Moisture Sensitivity Level (MSL): --
Function: Off-Delay, On-Delay
Circuit: 4PDT (4 Form C)
Delay Time: 2 Sec ~ 60 Sec
Contact Rating @ Voltage: 3A @ 250VAC
Voltage - Supply: 200 ~ 230VAC
Mounting Type: Socketable
Termination Style: Plug In
Timing Adjustment Method: Hand Dial
Timing Initiate Method: Input Voltage
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Time delay relays are used to provide an output after a predetermined amount of time has elapsed, and the H3Y-4 AC200-230 60S is no exception. This specific time delay relay has various applications in automation such as motor starters, production line control, and pump control. Furthermore, it has a timer function selectable between manual or automatic reset, a power saving feature, and a timer range of 0.05 seconds to 100 hours. In this article, we will explain how the H3Y-4 AC200-230 60S works and the main fields it can be utilized in.

Overview

The H3Y-4 AC200-230 60S is a general purpose time delay relay that is typically used for motor starters, production line control, and pump control. It can be triggered by an external voltage or control switch and has an adjustable time interval of 0.05 seconds to 100 hours that can be adjusted with a dial.

The H3Y-4 AC200-230 60S has a timer function selectable between manual and automatic reset. It also has voltage and current ratings of 200 to 230 VAC, and a maximum current of up to 15A. It is small, lightweight, and consists of a dustproof and waterproof case. In addition, it has a power saving feature that allows the timer to be operated with a lower input voltage that is at least 80% of the rated voltage.

Working Principle

The working principle of the H3Y-4 AC200-230 60S is fairly simple. When triggered by an external voltage or control switch, the time delay relay starts a timer. Once the timer reaches its predetermined time delay, it triggers an output. The timer can be set to a minimum of 0.05 seconds to a maximum of 100 hours by adjusting the time dial. By adjusting the timer delay, the user can control the timing of the output.

The H3Y-4 AC200-230 60S has a timer function selectable between manual and automatic reset. Manual reset requires user intervention to reset the timer after the predetermined time delay, while automatic reset allows the timer to reset itself after the predetermined time delay. The H3Y-4 AC200-230 60S also has a power saving feature that allows the timer to operate with a lower input voltage.

Application Field

The H3Y-4 AC200-230 60S is mainly used for motor starters, production line control, and pump control. Motor starters are used to control the starting and stopping of a motor. The timer delay can be adjusted to control the timing of the motor starting and stopping. Production line control is used to control the operation of a production line. The timer delay can be adjusted to control the timing of the production line operation. Lastly, the H3Y-4 AC200-230 60S can be used for pump control, where the timer delay can be adjusted to control the timing of a pump.

Conclusion

The H3Y-4 AC200-230 60S is a general purpose time delay relay that is typically used for motor starters, production line control, and pump control. It can be triggered by an external voltage or control switch and has an adjustable time interval between 0.05 seconds to 100 hours. The H3Y-4 AC200-230 60S has timer functions selectable between manual and automatic reset, as well as a power saving feature that allows it to be operated with a lower input voltage. The H3Y-4 AC200-230 60S has various applications such as motor starters, production line control, and pump control.

The specific data is subject to PDF, and the above content is for reference

Latest Products
DBB51CM2410S

SPDT DELAY ON RELEASE TIMR 10STime Delay...

DBB51CM2410S Allicdata Electronics
7-1437433-1

COMMERCIAL 2100Time Delay Relay Delay

7-1437433-1 Allicdata Electronics
1-1423153-0

COMMERCIAL 2100Time Delay Relay Delay

1-1423153-0 Allicdata Electronics
3-1437440-6

RELAY TIME DELAYTime Delay Relay Delay

3-1437440-6 Allicdata Electronics
1-1423158-0

RELAY TIME DELAYTime Delay Relay Delay

1-1423158-0 Allicdata Electronics
3-1423161-1

RELAY TIME DELAYTime Delay Relay Delay

3-1423161-1 Allicdata Electronics