Allicdata Part #: | 1780-1000-ND |
Manufacturer Part#: |
ISOBLOCK I-FG-4C (25A 10V) |
Price: | $ 452.19 |
Product Category: | Industrial Controls |
Manufacturer: | Verivolt LLC |
Short Description: | MONITOR CURRENT SENSE 25A 4CH |
More Detail: | N/A |
DataSheet: | ISOBLOCK I-FG-4C (25A 10V) Datasheet/PDF |
Quantity: | 3 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 411.07500 |
10 +: | $ 397.37200 |
Series: | IsoBlock I-FG |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Type: | Current Transducer |
Moisture Sensitivity Level (MSL): | -- |
Input Range: | 0 ~ 25A |
Output: | ±10VDC |
Response Time: | 5µs |
Accuracy: | ±0.2% |
Voltage - Supply: | 8 ~ 28VDC |
Mounting Type: | DIN Rail |
Termination Style: | Screw Terminal |
Operating Temperature: | -25°C ~ 65°C |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Monitoring current or voltage accurately is one of the main tasks of a monitoring system, and the application and working principle of transducers such as the ISOBLOCK I-FG-4C (25A 10V) is a key factor in this process. Although the precise arrangement of the internal construction differs, all transducers of this type usually contain a transformer or current transformer. This section provides a useful insight into the application field and working principle of this type of transducer.
Transducers of this type, such as the ISOBLOCK I-FG-4C, are mainly used in conjunction with electrical metering systems. In this way, any changes to the input voltage or current can be accurately recorded and analysed. This data is usually used in the form of direct current (DC) signals that are proportional to the input signals. In addition, these transducers can also be used to monitor and adjust the current or voltage on the output ports.
The way these transducers work is fairly simple. When input signals (current or voltage) are received, the transducer converts them into secondary signals of equivalent electrical value. This expression of secondary signals provides the observer with an indication of the input, and allows them to make necessary adjustments to ensure that the output remains constant.
The primary components used in the ISOBLOCK I-FG-4 understand transducer are mainly transformers. These devices work by using electrical energy to create a magnetic field, which in turn causes a current to flow through the secondary winding. The current produced is then proportional to the current or voltage received, according to the law of induction.
It is also worth noting that these transducers can also be used as part of a measuring system, as well as to accurately monitor and regulate the voltage or current on the output ports. To use the ISOBLOCK I-FG-4 as a monitor, the user must connect it to the voltage or current source and to the source of the transformer output. The transducer will then convert the input signal into the corresponding output signal.
Sometimes, these transducers may also be used in conjunction with a programmable logic controller (PLC). In this configuration, the transducer will provide voltage or current input signals to the PLC, which then processes the signals to create an output signal. This output signal is then used to control the equipment connected to the PLC.
It is important to note that the ISOBLOCK I-FG-4 is designed for use in applications where safety is of utmost importance, and should not be used on systems that are not designed for safety. Always ensure that the transducer is used in accordance with the manufacturer’s instructions. Failure to follow the instructions may lead to severe injury or even death.
In conclusion, the ISOBLOCK I-FG-4C (25A 10V) current and voltage transducers are designed to provide accurate monitoring and regulation of current and voltage. They use transformers or current transformers to convert input signals into secondary signals of equivalent electrical value, which are then used to make necessary adjustments to ensure accuracy and stability. In addition, the transducer can also be used in conjunction with a PLC to provide regulated output signals, thus making it an extremely useful tool for monitoring applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
ISOBLOCK V-4C (50V 5V) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 50VIN 5... |
ISOBLOCK V-1C (500VAC 7VAC) | Verivolt LLC | 197.3 $ | 1000 | MONITOR VOLT SENS 500VIN ... |
ISOBLOCK V-1C (250VAC 7VAC) | Verivolt LLC | 197.3 $ | 1000 | MONITOR VOLT SENS 250VIN ... |
ISOBLOCK V-1C (150VAC 7VAC) | Verivolt LLC | 197.3 $ | 1000 | MONITOR VOLT SENS 150VIN ... |
ISOBLOCK V-1C (1500V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 1500VIN... |
ISOBLOCK V-1C (1000V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 1000VIN... |
ISOBLOCK V-1C (750V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 750VIN ... |
ISOBLOCK V-1C (500V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 500VIN ... |
ISOBLOCK V-1C (300V 10V0.1%) | Verivolt LLC | 349.06 $ | 999 | MONITOR VOLT SENS 300VIN ... |
ISOBLOCK V-1C (200V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 200VIN ... |
ISOBLOCK V-1C (100V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 300VIN ... |
ISOBLOCK V-1C (50V 10V0.1%) | Verivolt LLC | 349.06 $ | 1000 | MONITOR VOLT SENS 50VIN 1... |
ISOBLOCK I-FG-4C (50A 10V) | Verivolt LLC | 452.19 $ | 1000 | MONITOR CURRENT SENSE 50A... |
ISOBLOCK I-FG-4C (6A 10V) | Verivolt LLC | 452.19 $ | 1000 | MONITOR CURRENT SENSE 6A ... |
ISOBLOCK I-FG-4C (50A 5V) | Verivolt LLC | 452.19 $ | 1000 | MONITOR CURRENT SENSE 50A... |
ISOBLOCK V-4C (750V 10V) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 750VIN ... |
ISOBLOCK V-4C (500VAC 7VAC) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 500VIN ... |
ISOBLOCK V-4C (750V 5V) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 750VIN ... |
ISOBLOCK V-4C (500V 5V) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 500VIN ... |
ISOBLOCK V-4C (300V 5V) | Verivolt LLC | 660.19 $ | 1000 | MONITOR VOLT SENS 300VIN ... |
ISOBLOCK V-4C (1500V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | SENSOR VOLT 1500V HI PERF |
ISOBLOCK V-4C (1000V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | SENSOR VOLT 1000V HI PERF |
ISOBLOCK V-4C (750V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | SENSOR VOLT 750V HI PERF |
ISOBLOCK V-4C (500VAC 7VAC0.1%) | Verivolt LLC | 0.69 $ | 1000 | SENSOR VOLT 7V HI PERF |
ISOBLOCK V-4C (500V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 500VIN ... |
ISOBLOCK V-4C (300V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 300VIN ... |
ISOBLOCK V-4C (250VAC 7VAC0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 100VIN ... |
ISOBLOCK V-4C (150VAC 7VAC0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 50VIN 7... |
ISOBLOCK V-4C (100V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 100VIN ... |
ISOBLOCK V-4C (50V 10V0.1%) | Verivolt LLC | 0.69 $ | 1000 | MONITOR VOLT SENS 50VIN 1... |
ISOBLOCK Q-4C (HR) | Verivolt LLC | 0.69 $ | 1000 | ISOLATOION AMP QUAD HR |
ISOBLOCK Q-4C (LR) | Verivolt LLC | 0.69 $ | 1000 | ISOLATOION AMP QUAD LR |
ISOBAR6DBS | Tripp Lite | 56.35 $ | 1000 | SURGE SUPP DSS 6OUT 6'COR... |
ISOBLOCK I-FG-1C (25A 10V) | Verivolt LLC | 125.22 $ | 9 | MONITOR CURRENT SENSE 25A |
ISOBLOCK I-FG-1C (15A 10V) | Verivolt LLC | 125.22 $ | 4 | MONITOR CURRENT SENSE 15A |
ISOBLOCK I-FG-1C (50A 10V) | Verivolt LLC | 125.22 $ | 33 | MONITOR CURRENT SENSE 50A |
ISOBLOCK I-FG-1C (25A 5V) | Verivolt LLC | 125.22 $ | 3 | MONITOR CURRENT SENSE 25A |
ISOBLOCK I-FG-1C (15A 5V) | Verivolt LLC | 125.22 $ | 3 | MONITOR CURRENT SENSE 15A |
ISOBLOCK I-FG-1C (6A 10V) | Verivolt LLC | 125.22 $ | 2 | MONITOR CURRENT SENSE 6A |
ISOBLOCK I-FG-1C (50A 5V) | Verivolt LLC | 125.22 $ | 1 | MONITOR CURRENT SENSE 50A |
VOLT DIVIDER 3KV IN 200MV OUT
VOLT DIVIDER 5KV IN 200MV OUT
SIGNAL CONVERTER/DISCONNECTOR
TRANSDUCER MEASURING
TRANSDUCR AC VOLT 5V-OUT 500V-IN
VOLT DIVIDER 2KV IN 200MV OUT