Allicdata Part #: | L18P020S12-ND |
Manufacturer Part#: |
L18P020S12 |
Price: | $ 4.96 |
Product Category: | Sensors, Transducers |
Manufacturer: | Tamura |
Short Description: | SENSOR CURRENT HALL 20A AC/DC |
More Detail: | Current Sensor 20A 1 Channel Hall Effect, Open Loo... |
DataSheet: | ![]() |
Quantity: | 1000 |
600 +: | $ 4.51143 |
Frequency: | DC ~ 100kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -30°C ~ 80°C |
Current - Supply (Max): | 15mA |
Response Time: | 5µs |
Voltage - Supply: | 12V |
Accuracy: | -- |
Linearity: | ±1% |
Series: | L18PXXXS12 |
Sensitivity: | -- |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 20A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are important instruments in the electricity industry. They are used to measure and control current flows in power networks. The L18P020S12 is one such current transducer. It is a single-phase current transformer with an advanced switching technology and two independent components: an electronic module and a primary transformer.
The L18P020S12 has a wide application field due to its accurate current measurement as well as its high power handling capability. It is mainly used in medium to high power applications such as power stations, electricity distribution companies, electrical sub-stations, and engineering works. Other applications include electrical motor control systems, ventilation systems, HVAC, lighting, and power quality monitoring.
The working principle of the L18P020S12 is based on its two independent components: the primary transformer and the electronic module. The primary transformer measures the current in the system and converts it to a low voltage signal, which is then sent to the electronic module. The module amplifies the signal from the transformer and sends it to the measuring system. The output of the module can be monitored and used in controlling the system.
In conclusion, the L18P020S12 current transducer is a valuable instrument that is used in many electrical applications to measure and control current flows. It is composed of two independent components, the primary transformer and the electronic module, and its working principle is based on its two components. It is mainly used in medium to high power applications such as power stations, electrical sub-stations, and engineering works.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
L18P025D15 | Tamura | -- | 585 | SENSOR CURRENT HALL 25A A... |
L18P050D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 50A A... |
L18P030S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 30A A... |
L18P003S12 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P005S05 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P010S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P060S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P003D15 | Tamura | -- | 1885 | SENSOR CURRENT HALL 3A AC... |
L18P040D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 40A A... |
L18P020D15 | Tamura | 7.05 $ | 660 | SENSOR CURRENT HALL 20A A... |
L18P025S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P005D15 | Tamura | 6.12 $ | 1113 | SENSOR CURRENT HALL 5A AC... |
L18P015S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P025S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P060S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P025D15C | Tamura | 4.42 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P015S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P040S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P050S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P020S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 20A A... |
L18P020S05 | Tamura | 8.58 $ | 89 | SENSOR CURRENT HALL 20A A... |
L18P003S05R | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P060S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P060D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 60A A... |
L18P010S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P050S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P010D15 | Tamura | -- | 279 | SENSOR CURRENT HALL 10A A... |
L18P030D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 30A A... |
L18P050S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P010S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P025S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P003S05 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P005S05R | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P015S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P030S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 30A A... |
L18P005S12 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P040S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P040S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P020S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 20A A... |
L18P015D15 | Tamura | -- | 49 | SENSOR CURRENT HALL 15A A... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...

SENSOR CURRENT XFMR 5A ACCurrent Sensor ...

SENSOR CURRENT HALL 15A AC/DCCurrent Sen...

3 PIECE KIT SENSOR CURRENT HALLCurrent S...

PACT RCP-4000A-1A-D190Current Sensor 100...

SENSOR CURRENT HALL 30A DCCurrent Sensor...