Allicdata Part #: | L18P030S05R-ND |
Manufacturer Part#: |
L18P030S05R |
Price: | $ 4.96 |
Product Category: | Sensors, Transducers |
Manufacturer: | Tamura |
Short Description: | SENSOR CURRENT HALL 30A AC/DC |
More Detail: | Current Sensor 30A 1 Channel Hall Effect, Open Loo... |
DataSheet: | ![]() |
Quantity: | 1000 |
600 +: | $ 4.51143 |
Frequency: | DC ~ 100kHz |
Package / Case: | Module |
Mounting Type: | Through Hole |
Polarization: | Bidirectional |
Operating Temperature: | -30°C ~ 80°C |
Current - Supply (Max): | 15mA |
Response Time: | 5µs |
Voltage - Supply: | 5V |
Accuracy: | -- |
Linearity: | ±1% |
Series: | L18PXXXS05 |
Sensitivity: | -- |
Output: | Ratiometric, Voltage |
Number of Channels: | 1 |
Current - Sensing: | 30A |
Sensor Type: | Hall Effect, Open Loop |
For Measuring: | AC/DC |
Part Status: | Active |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current transducers are an important component of power management systems. Their purpose is to measure the amount of current that flows through an electrical system. The transducer\'s main job is to convert an electrical current, such as an AC sine wave into an appropriate digital or analog signal. The resulting signal is then processed by a computer or other hardware to calculate current, voltage, and other parameters.
The L18P030S05R is a current transducer that can measure AC and DC currents. It features a low-pass filter which filters out high frequency disturbances and unwanted noise, providing clean, accurate output signals. Moreover, it has a built-in temperature sensor which can be used to monitor the temperature of the transducer, ensuring its robust operation and reliable performance.
The L18P030S05R has wide range of applications in a number of industries. The most common uses are in the automotive and industrial power control systems. It is also used in AC power distribution systems to regulate currents and prevent large spikes in voltage and current. Additionally, it can be used in medical, aerospace, and military systems, as well as other demanding applications.
The working principle of the L18P030S05R transducer is based on the Faraday’s law of electromagnetic induction. When an electrical current is applied to the transducer, it induces a magnetic field around it. This field interacts with a secondary winding located inside the transducer, which results in a voltage being produced. This voltage is then converted to an appropriate digital or analog signal, which can be used for various calculations.
The L18P030S05R is a well-designed and reliable current transducer. It offers many advantages over other types of transducers, including high accuracy, low cost, durability, and wide application range. It is also easy to install and maintain, allowing it to provide reliable readings in any environment.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
L18P025D15 | Tamura | -- | 585 | SENSOR CURRENT HALL 25A A... |
L18P050D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 50A A... |
L18P030S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 30A A... |
L18P003S12 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P005S05 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P010S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P060S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P003D15 | Tamura | -- | 1885 | SENSOR CURRENT HALL 3A AC... |
L18P040D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 40A A... |
L18P020D15 | Tamura | 7.05 $ | 660 | SENSOR CURRENT HALL 20A A... |
L18P025S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P005D15 | Tamura | 6.12 $ | 1113 | SENSOR CURRENT HALL 5A AC... |
L18P015S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P025S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P060S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P025D15C | Tamura | 4.42 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P015S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P040S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P050S12 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P020S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 20A A... |
L18P020S05 | Tamura | 8.58 $ | 89 | SENSOR CURRENT HALL 20A A... |
L18P003S05R | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P060S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 60A A... |
L18P060D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 60A A... |
L18P010S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P050S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P010D15 | Tamura | -- | 279 | SENSOR CURRENT HALL 10A A... |
L18P030D15 | Tamura | -- | 1000 | SENSOR CURRENT HALL 30A A... |
L18P050S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 50A A... |
L18P010S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 10A A... |
L18P025S05 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 25A A... |
L18P003S05 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 3A AC... |
L18P005S05R | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P015S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 15A A... |
L18P030S05R | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 30A A... |
L18P005S12 | Tamura | 4.01 $ | 1000 | SENSOR CURRENT HALL 5A AC... |
L18P040S05R | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P040S05 | Tamura | 5.31 $ | 1000 | SENSOR CURRENT HALL 40A A... |
L18P020S12 | Tamura | 4.96 $ | 1000 | SENSOR CURRENT HALL 20A A... |
L18P015D15 | Tamura | -- | 49 | SENSOR CURRENT HALL 15A A... |
SENSOR CURRENT XFMR 40A ACCurrent Sensor...

SENSOR CURRENT XFMR 5A ACCurrent Sensor ...

SENSOR CURRENT HALL 15A AC/DCCurrent Sen...

3 PIECE KIT SENSOR CURRENT HALLCurrent S...

PACT RCP-4000A-1A-D190Current Sensor 100...

SENSOR CURRENT HALL 30A DCCurrent Sensor...