Allicdata Part #: | MK2PN-S-DC6-ND |
Manufacturer Part#: |
MK2PN-S-DC6 |
Price: | $ 0.00 |
Product Category: | Relays |
Manufacturer: | Omron Automation and Safety |
Short Description: | RELAY GEN PURPOSE DPDT 10A 6V |
More Detail: | General Purpose Relay DPDT (2 Form C) 6VDC Coil So... |
DataSheet: | MK2PN-S-DC6 Datasheet/PDF |
Quantity: | 1000 |
1 +: | 0.00000 |
Turn On Voltage (Max): | 4.8 VDC |
Coil Resistance: | 23.5 Ohms |
Coil Power: | 1.5 W |
Contact Material: | Silver (Ag) |
Operating Temperature: | -10°C ~ 40°C |
Termination Style: | Plug In, 8 Pin (Octal) |
Mounting Type: | Socketable |
Features: | LED Indicator, Mechanical Indicator, Test Button |
Release Time: | 20ms |
Operate Time: | 30ms |
Turn Off Voltage (Min): | 0.9 VDC |
Series: | MK |
Switching Voltage: | 250VAC, 250VDC - Max |
Contact Rating (Current): | 10A |
Contact Form: | DPDT (2 Form C) |
Coil Voltage: | 6VDC |
Coil Current: | 255mA |
Coil Type: | Non Latching |
Relay Type: | General Purpose |
Part Status: | Obsolete |
Packaging: | Bulk |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Power relays that draw over 2 amps of current have to switch large amounts of power. These relays must be properly paired to the application for safety and reliability. An example of such a relay is the MK2PN-S-DC6. This article explains the application field and working principle of this particular power relay.
MK2PN-S-DC6 Application Field
The MK2PN-S-DC6 is a latching power relay suitable for switching loads ranging from 3 to 6 A. The rated working voltage of the product is 24 VDC, the maximum working voltage is 200 VDC, and the maximum switching voltage is 250 VDC. This power relay is suitable for both AC and DC applications. It features movable contacts and quick connect terminals for easy connection and disconnection. The product also has a variety of different mounting options, as well as a built-in diode that protects against voltage transients.
The MK2PN-S-DC6 can be used in a variety of applications such as household appliances, access control systems, and vending machines. It can also be used in automotive and aerospace applications, including air conditioning and fuel systems. The product is a reliable and cost-effective alternative to other relays, thanks to its low power consumption and simple design.
MK2PN-S-DC6 Working Principle
Under normal operating conditions, the MK2PN-S-DC6 is a sealed relay, meaning it is sealed in a special housing to reduce the possibility of electric shock. The internal circuit of the relay consists of a coil, a contact and a restraining coil. The power supply activates the coil, which then generates a magnetic field. This magnetic field acts on the contact and causes it to move, thereby switching the circuit on or off.
The feature that makes the MK2PN-S-DC6 a latching relay is the restraining coil. When the power is switched off, this coil creates a counter magnetic field, which in turn prevents the contact from moving and keeps the circuit from switching off. This ensures that the circuit stays in the same state after power is lost.
The MK2PN-S-DC6 is a reliable and cost-effective solution for switching loads over 2 amps of current. It has a rated voltage of 24 VDC and can handle loads up to 6 A. This power relay is suitable for AC and DC applications, as well as a variety of mounting options. Moreover, it features a built-in diode to protect against voltage transients, and includes a restraining coil to maintain the circuit state when power is lost.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
MK2PD-I-DC110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PD-S-DC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PD-S-DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC100 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC240 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC50 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AP3 AC120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AP3 AC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AP3 DC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-DC110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I DC120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-DC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-AC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-AC220 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-AC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-AC240 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-AC50 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-I-DC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-S-AC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-S-AC50 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-S AC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-S-DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2PN-S-DC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-AC100 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-AC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S DC125 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-DC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S DC60 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-AC120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-AC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-DC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-DC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-S-AC220 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
MK2P-I-AC120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 10... |
General Purpose Relay Power PCB Relay SP...
RELAY GENERAL PURPOSERelay Coil
RELAY GEN PURP 4PDT 48VACRelay Coil
RELAY GEN PURP 4PDTRelay Coil
RELAYRelay Coil
CONN TERM BLOCKRelay Coil