Allicdata Part #: | Z3368-ND |
Manufacturer Part#: |
MY2N-D2 DC12 (S) |
Price: | $ 12.93 |
Product Category: | Relays |
Manufacturer: | Omron Automation and Safety |
Short Description: | RELAY GEN PURPOSE DPDT 5A 12V |
More Detail: | General Purpose Relay DPDT (2 Form C) 12VDC Coil S... |
DataSheet: | MY2N-D2 DC12 (S) Datasheet/PDF |
Quantity: | 14 |
1 +: | $ 11.74950 |
10 +: | $ 10.44480 |
25 +: | $ 9.92250 |
50 +: | $ 9.40009 |
100 +: | $ 8.87789 |
250 +: | $ 8.09459 |
500 +: | $ 7.57232 |
Series: | MY |
Packaging: | Bulk |
Part Status: | Active |
Relay Type: | General Purpose |
Coil Type: | Non Latching |
Coil Current: | 75.0mA |
Coil Voltage: | 12VDC |
Contact Form: | DPDT (2 Form C) |
Contact Rating (Current): | 5A |
Switching Voltage: | 250VAC, 125VDC - Max |
Turn On Voltage (Max): | 9.6 VDC |
Turn Off Voltage (Min): | 1.2 VDC |
Operate Time: | 20ms |
Release Time: | 20ms |
Features: | Diode, LED Indicator |
Mounting Type: | Socketable |
Termination Style: | Plug In |
Operating Temperature: | -55°C ~ 70°C |
Contact Material: | Silver (Ag) |
Coil Power: | 900 mW |
Coil Resistance: | 160 Ohms |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
My2N-D2 DC12 (S) power relays are an ideal choice for industrial and commercial applications that require relays with a current capacity of over 2 Amps. The relays are designed for both AC and DC loads, and are UL and CSA approved. Polarity protection and surge suppression features and several other features make them a reliable choice for multiple applications.
Application Fields
My2N-D2 DC12 (S) power relays are designed for a broad range of applications, including but not limited to, lighting, heating, cooling, conveyor safety, motors, and pumps. They are also suitable for processes that require a high-reliability switching element, as well as applications that involve high-current loads. In addition, the relays can be used for a variety of domestic, commercial, and industrial safety systems, including emergency shut-off systems, fault protection systems, and protection from short-circuits or overloads.
Working Principle
My2N-D2 DC12 (S) power relays work by sensing changes in voltage, current, temperature, or other electrical property within an electrical circuit. When a sensor detects a certain set point or a particular condition, the relay activates and closes the electrical circuit, allowing the current to reach the desired destination. For example, when a current overload protection sensor detects that the current load is at an unsafe level, the power relay will automatically disconnect the power supply to prevent an overload or short circuit.
The main component of a power relay is the contact system. This consists of two or more sets of contacts, anchored to a beam that is actuated by a coil. When the coil is energized, the beam and contacts close, allowing current to pass through the relay.
My2N-D2 DC12 (S) power relays have a variety of features that make them suitable for a wide range of applications. These features include noise immunity, surge suppression, polarity protection, overload protection, and low voltage protection. All of these features help to ensure the relays are reliable, safe, and long-lasting.
Conclusion
So all in all, My2N-D2 DC12 (S) power relays are a great choice for applications that require a current capacity of over 2 Amps. The relays are suitable for a broad range of residential, commercial, and industrial applications, and their features make them a reliable and safe choice for any application.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
MY2N AC220/240 (S) | Omron Automa... | 12.28 $ | 775 | RELAY GEN PURPOSE DPDT 5A... |
MY2N AC110/120 (S) | Omron Automa... | 7.04 $ | 106 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-D2 DC24 (S) | Omron Automa... | 12.93 $ | 53 | RELAY GEN PURPOSE DPDT 5A... |
MY2N DC24 (S) | Omron Automa... | 6.81 $ | 69 | RELAY GEN PURPOSE DPDT 5A... |
MY2N DC12 (S) | Omron Automa... | 7.22 $ | 43 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-AC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-CR AC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-AC220/240 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-AC110/120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-CR AC200/220 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-DC24 | Omron Automa... | 9.64 $ | 60 | RELAY GEN PURPOSE DPDT 5A... |
MY2N AC24 (S) | Omron Automa... | 6.8 $ | 24 | RELAY GEN PURPOSE DPDT 5A... |
MY2N AC200/220 (S) | Omron Automa... | 7.91 $ | 24 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-D2 DC12 (S) | Omron Automa... | 12.93 $ | 14 | RELAY GEN PURPOSE DPDT 5A... |
MY2N-Y AC200/220 | Omron Automa... | 18.13 $ | 5 | RELAY GEN PURPOSE DPDT 7A... |
MY2N AC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-GS AC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-GS AC110/120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-GS AC200/220 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-GS AC220/240 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-GS DC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-GS DC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-GS DC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-GS DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS AC110/120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS AC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS AC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS DC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS DC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-GS DC6 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-J AC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-J AC110/120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-J AC200/220 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-CR-J AC220/240 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-J DC100/110 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-J DC12 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-J DC24 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-D2-J DC48 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
MY2N-J AC110/120 | Omron Automa... | 0.0 $ | 1000 | RELAY GEN PURP DPDTRelay ... |
General Purpose Relay Power PCB Relay SP...
RELAY GENERAL PURPOSERelay Coil
RELAY GEN PURP 4PDT 48VACRelay Coil
RELAY GEN PURP 4PDTRelay Coil
RELAYRelay Coil
CONN TERM BLOCKRelay Coil