
Allicdata Part #: | P51-100-S-AA-I12-20MA-000-000-ND |
Manufacturer Part#: |
P51-100-S-AA-I12-20MA-000-000 |
Price: | $ 90.19 |
Product Category: | Sensors, Transducers |
Manufacturer: | SSI Technologies Inc |
Short Description: | SENSOR 100PSIS 7/16 UNF 4-20 MA |
More Detail: | Pressure Sensor 100 PSI (689.48 kPa) Sealed Gauge ... |
DataSheet: | ![]() |
Quantity: | 1000 |
5 +: | $ 81.99100 |
Specifications
Series: | MediaSensor™ |
Part Status: | Active |
Pressure Type: | Sealed Gauge |
Operating Pressure: | 100 PSI (689.48 kPa) |
Output Type: | Analog Current |
Output: | 4 mA ~ 20 mA |
Accuracy: | ±0.5% |
Voltage - Supply: | 8 V ~ 30 V |
Port Size: | Male - 7/16" (11.11mm) UNF |
Port Style: | Threaded |
Features: | Amplified Output, Temperature Compensated |
Termination Style: | Cable 1' |
Maximum Pressure: | -- |
Operating Temperature: | -40°C ~ 105°C |
Package / Case: | Cylinder |
Supplier Device Package: | -- |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Pressure Sensors, Transducers
P51-100-S-AA-I12-20MA-000-000 is a type of pressure sensor, transducer that measures the pressure, force or displacement of gases and liquids. It is made up of a pressurized sensing element, usually a diaphragm, and a base leadboard containing integrated electronic circuits and connections. The sensing element senses the pressure from the pressure port and sends an electrical signal to a transducer amplifier, which then sends an output signal into the load and signal port. The transducer amplifier then amplifies the signal, which is converted from one form of energy to another, so that a digital signal can be read by an electronic program. The output from the transducer amplifiers is transmitted to a third port, which is the output port, where it can be read by a computer, display, or other electronic device. Typically, pressure sensors have characteristics such as pressure range and pressure type. Pressure range refers to the amount of pressure that can be measured before a system is considered outside of its normal operating range. Pressure type refers to the type of pressure that can be measured, such as absolute, gauge, or differential. The working principle of a pressure transducer is based on the concept of the Wheatstone bridge. A Wheatstone bridge is an electrical circuit composed of four resistors connected in a bridge configuration. The bridge configuration creates a voltage divider that produces a voltage output signal based on the changes in the resistance in each of the resistors. The pressure transducer is designed so that when pressure is applied to the sensing element, the resistance in the bridge circuit changes. This change in resistance is then translated into a voltage, which is sent to the transducer amplifier. The transducer amplifier amplifies the signal and sends an output, which is then transmitted to the third port. The range of pressure that a pressure transducer can measure is determined by the design of the sensing element. For example, a transducer designed to measure pressure up to 50 psi could also be used to measure points below that. The maximum output of a pressure transducer is typically limited by the maximum input the transducer amplifier can handle. P51-100-S-AA-I12-20MA-000-000 is a type of pressure sensor, transducer that is designed for general purpose applications. It has an operating temperature of -40 to +140°F and is designed to work with a broad range of pressure liquids and gases. The transducer is powered by a 12-20mA current and has a 0.4-2.0 inHg range. The P51-100-S-AA-I12-20MA-000-000 is commonly used in many types of commercial and industrial applications, such as factory automation, process control, material handling, and energy managements systems. Generally, the pressure transducer is used to measure air pressure, water pressure, and other types of hydraulic and pneumatic pressure. The P51-100-S-AA-I12-20MA-000-000 pressure transducer can be connected to a variety of systems other than the primary sensing point. Some of these systems include indicator devices, computers, and other third-party systems. The transducer can be connected to any of these systems using a variety of different connection types, such as Modbus and 4-20mA. Pressure transducers are an important component in many systems because they are reliable, repeatable, and accurate. They are also relatively easy to install and maintain. The P51-100-S-AA-I12-20MA-000-000 pressure transducer is a reliable and accurate device that is designed for a variety of applications.The specific data is subject to PDF, and the above content is for reference
Latest Products
9781101
SST PRESSURE TRANSDUCERPressure Sensor

IPSU-G1003-5
PRSSR TRNS 0-100BR 4-20MA DINPressure Se...

SSCSLNT001BD3A3
BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCMRRN005NDAA5
BRD MNT PRESSURE SENSORSPressure Sensor ...

PX2EG1XX040BSCHX
HEAVY DUTY PRESSURE TRANSDUCERPressure S...

NBPMANS100MGUNV
BRD MNT PRESSURE SENSORSPressure Sensor ...
