Specifications
Series: MediaSensor™
Part Status: Active
Pressure Type: Sealed Gauge
Operating Pressure: 200 PSI (1378.95 kPa)
Output Type: Analog Voltage
Output: 0.5 V ~ 4.5 V
Accuracy: ±0.5%
Voltage - Supply: 5V
Port Size: Male - 1/4" (6.35mm) NPT
Port Style: Threaded
Features: Amplified Output, Temperature Compensated
Termination Style: Cable 3'
Maximum Pressure: --
Operating Temperature: -40°C ~ 105°C
Package / Case: Cylinder
Supplier Device Package: --
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Introduction to Pressure Sensors, Transducers and P51-200-S-A-I36-4.5OVP-000-000

Pressure is one of the five fundamental physical properties of matter. It can be measured in various ways, including with pressure sensors, transducers, and various types of gauges. Pressure sensors, transducers, and gauges have three primary functions: to measure pressure, to convert mechanical energy to electrical energy, or to convert electrical energy to mechanical energy. P51-200-S-A-I36-4.5OVP-000-000 is one type of pressure sensors, transducers and performs these functions.

Application Field and Working Principle of P51-200-S-A-I36-4.5OVP-000-000

P51-200-S-A-I36-4.5OVP-000-000 can be used for monitoring pressure in a wide range of industrial and consumer applications, such as medical, aerospace, and automotive industries, and for measuring pressure in various liquids, gases, and vacuum applications. The principle of operation of this type of pressure sensor is based on the Wheatstone bridge circuit. It consists of four strain-gauge resistors arranged in a bridge configuration. The resistance of the two series-connected strain-gauge resistors changes with the applied force due to the various factors as explained below.

Factors Affecting Resistance Change

The strain-gauge resistors are made from materials that are sensitive to strain. When there is an increase in pressure, the resistors deform, causing a reduction in resistance. Conversely, when there is a decrease in pressure, the resistance of the resistors increases. This resistance change is due to three main factors. The first factor is the material\'s inherent resistance to strain. The second factor is the strain\'s elasticity. Finally, the third factor is the temperature coefficient of the material. These three factors work together to determine the amount of strain caused by the applied force and, ultimately, the amount of resistance change.

Operation

The Wheatstone bridge circuit is used to measure the resistance change of the strain-gauge resistors. In this circuit, the resistors on one side of the bridge are connected in series and the other side is connected in parallel. When there is a pressure change, the resistance of the two series-connected resistors changes and causes a voltage imbalance between the two sides of the bridge. This voltage imbalance can be measured and used to determine the magnitude and direction of the pressure change.

Advantages and Disadvantages

The major advantage of P51-200-S-A-I36-4.5OVP-000-000 is its high accuracy and reliability. This type of pressure sensor is also small in size, making it suitable for use in compact systems. Additionally, it can be used to measure pressure in extreme environments, such as underwater or high-temperature applications. On the other hand, its major disadvantage is its narrow range of application. This type of pressure sensor is only suitable for applications where the pressure range is between 0-200 psi. Moreover, P51-200-S-A-I36-4.5OVP-000-000 can be costly to purchase.

Conclusion

P51-200-S-A-I36-4.5OVP-000-000 is a type of pressure sensor, transducer that can be used to measure pressure in various liquids, gases, and vacuum applications. This type of pressure sensor is small in size and has high accuracy and reliability. It can be used in extreme environments and is suitable for applications where the pressure range is between 0-200 psi. Its major disadvantage is its narrow range of application and cost.

The specific data is subject to PDF, and the above content is for reference

Latest Products
9781101

SST PRESSURE TRANSDUCERPressure Sensor

9781101 Allicdata Electronics
IPSU-G1003-5

PRSSR TRNS 0-100BR 4-20MA DINPressure Se...

IPSU-G1003-5 Allicdata Electronics
SSCSLNT001BD3A3

BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCSLNT001BD3A3 Allicdata Electronics
SSCMRRN005NDAA5

BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCMRRN005NDAA5 Allicdata Electronics
PX2EG1XX040BSCHX

HEAVY DUTY PRESSURE TRANSDUCERPressure S...

PX2EG1XX040BSCHX Allicdata Electronics
NBPMANS100MGUNV

BRD MNT PRESSURE SENSORSPressure Sensor ...

NBPMANS100MGUNV Allicdata Electronics