Allicdata Part #: | P51-3000-S-J-MD-4.5V-000-000-ND |
Manufacturer Part#: |
P51-3000-S-J-MD-4.5V-000-000 |
Price: | $ 93.26 |
Product Category: | Sensors, Transducers |
Manufacturer: | SSI Technologies Inc |
Short Description: | SENSOR 3000PSI 3/8-24 UNF 4.5V |
More Detail: | Pressure Sensor 3000 PSI (20684.27 kPa) Sealed Gau... |
DataSheet: | ![]() |
Quantity: | 1000 |
5 +: | $ 84.77770 |
Specifications
Series: | MediaSensor™ |
Part Status: | Active |
Pressure Type: | Sealed Gauge |
Operating Pressure: | 3000 PSI (20684.27 kPa) |
Output Type: | Analog Voltage |
Output: | 0.5 V ~ 4.5 V |
Accuracy: | ±0.5% |
Voltage - Supply: | 5V |
Port Size: | Male - 3/8" (9.52mm) UNF |
Port Style: | Threaded |
Features: | Amplified Output, Temperature Compensated |
Termination Style: | MD, 4 Pin |
Maximum Pressure: | -- |
Operating Temperature: | -40°C ~ 105°C |
Package / Case: | Cylinder |
Supplier Device Package: | -- |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Pressure Sensors,Transducers
P51-3000-S-J-MD-4.5V-000-000 pressure transducers are devices used to measure pressure. They often consist of a pressure sensing element that has a diaphragm, a pressure-sensing cell, and some form of signal output such as a voltage, current, etc. Pressure transducers are used in a wide range of applications, from industrial processes to medical systems. The working principle of a pressure transducer is usually based on the measurement of resistance, capacitance, or both. This article will discuss the application field and working principle of P51-3000-S-J-MD-4.5V-000-000 pressure transducers.
One of the most common application fields for P51-3000-S-J-MD-4.5V-000-000 pressure transducers is within industrial process control. Here, the pressure transducer is used to measure and control various pressures within a system. This could include measuring the pressure of a gas or liquid within a process, or controlling the pressure in a pipe or container. In some industrial applications, the pressure transducer is used in a closed-loop system, such as in a pneumatic or hydraulic system. Here, the pressure transducer monitors the pressure and sends a signal to a controller. The controller then takes action, such as increasing or decreasing the pressure, based on the signal.
Another application field for P51-3000-S-J-MD-4.5V-000-000 pressure transducers is in medical devices. Here, the transducer is used to measure blood pressure, or other pressure levels within the body, such as within the lungs or heart. Pressure transducers are also often used in breathalyzers, where the pressure transducer can measure the pressure of air within the lungs of a person who has been drinking alcohol.
The working principle of P51-3000-S-J-MD-4.5V-000-000 pressure transducers is usually based on the measurement of resistance, capacitance, or a combination of both. This is due to the fact that pressure is related to resistance or capacitance because the amount of force that is applied to a sensing element will cause a change in either resistance or capacitance. For resistance-based pressure transducers, a sensing element which consists of a set of wires is embedded in a flexible material that can deform when pressure is applied to it. As the pressure is increased, the electrical resistance of the wires is also increased, thus providing a signal that can be used to measure the pressure. For capacitance-based pressure transducers, a sensing element comprises two plates that are insulated from each other. When pressure is applied to the plates, the amount of capacitance between them changes, thus providing a signal that can be used to measure the pressure.
In addition to the application field and working principle of P51-3000-S-J-MD-4.5V-000-000 pressure transducers, there are other important factors to consider when selecting a pressure transducer. These include the accuracy of the pressure transducer, its environmental resistance, its electrical specifications, and its pressure range. The accuracy of the transducer will determine the accuracy of the measurement, and the environmental resistance characteristics will determine whether it can be used in harsh environments. The electrical specifications will determine the type of wiring and connectors that will be needed for operation, and the pressure range will determine the range of pressure measurements that can be made. By considering these factors, the most appropriate P51-3000-S-J-MD-4.5V-000-000 pressure transducer can be selected for the application.
The specific data is subject to PDF, and the above content is for reference
Latest Products
9781101
SST PRESSURE TRANSDUCERPressure Sensor

IPSU-G1003-5
PRSSR TRNS 0-100BR 4-20MA DINPressure Se...

SSCSLNT001BD3A3
BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCMRRN005NDAA5
BRD MNT PRESSURE SENSORSPressure Sensor ...

PX2EG1XX040BSCHX
HEAVY DUTY PRESSURE TRANSDUCERPressure S...

NBPMANS100MGUNV
BRD MNT PRESSURE SENSORSPressure Sensor ...