P51-50-A-Y-P-4.5OVP-000-000 Allicdata Electronics
Allicdata Part #:

P51-50-A-Y-P-4.5OVP-000-000-ND

Manufacturer Part#:

P51-50-A-Y-P-4.5OVP-000-000

Price: $ 93.26
Product Category:

Sensors, Transducers

Manufacturer: SSI Technologies Inc
Short Description: SENSOR 50PSI 7/16-20-2B .5-4.5V
More Detail: Pressure Sensor 50 PSI (344.74 kPa) Absolute Femal...
DataSheet: P51-50-A-Y-P-4.5OVP-000-000 datasheetP51-50-A-Y-P-4.5OVP-000-000 Datasheet/PDF
Quantity: 1000
5 +: $ 84.77770
Stock 1000Can Ship Immediately
$ 93.26
Specifications
Series: MediaSensor™
Part Status: Active
Pressure Type: Absolute
Operating Pressure: 50 PSI (344.74 kPa)
Output Type: Analog Voltage
Output: 0.5 V ~ 4.5 V
Accuracy: ±1%
Voltage - Supply: 5V
Port Size: Female - 7/16" (11.11mm) UNF
Port Style: Threaded
Features: Amplified Output, Temperature Compensated
Termination Style: Packard, 3 Pin
Maximum Pressure: --
Operating Temperature: -40°C ~ 105°C
Package / Case: Cylinder
Supplier Device Package: --
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Pressure sensors, transducers, and P51-50-A-Y-P-4.5OVP-000-000 are components of a pressure system used to measure various parameters of a given fluid field. Pressure transducers are used to convert mechanical pressure into an electrical signal. The P51-50-A-Y-P-4.5OVP-000-000 is a type of pressure transducer used in a wide range of applications including industrial process control, air-flow analysis, and medical research.A pressure transducer system is composed of at least three components: the primary sensing element, the signal conditioning circuitry, and the output device. The primary sensing element is the part that measures the pressure, and it consists of an assemblage of materials that will generate a signal when subjected to pressure. The signal conditioner amplifies the signal generated by the primary transducer and converts it into a standard electrical signal. The output device is typically a display or a controller, which is triggered by the received signal and in turn activates another part of the system.The P51-50-A-Y-P-4.5OVP-000-000 is a pressure transducer system that comes in several different configurations. Depending on the application, the unit can be used to measure pressure, pressure differences, or flow rates. The unit is designed for use in low-pressure applications, and it is designed with an accuracy level of 0.25%.The primary sensing element of the P51-50-A-Y-P-4.5OVP-000-000 is a piezoelectric ceramic crystal that generates an electrical charge when it is subjected to pressure. The crystal is protected by metal diaphragms that are used to protect the crystal from contaminants. The transduction also contains a damping element to limit the resonances of the ceramic element and thus increase the maximum frequency response of the system.The signal conditioning circuitry of the P51-50-A-Y-P-4.5OVP-000-000 is an integrated circuit that amplifies the electrical signal generated by the ceramic crystal and filters the signal to reduce the noise generated by outside sources. The output from the signal conditioning circuitry is a linear voltage signal that is proportional to the pressure. The signal is then processed by a controller that will adjust the settings of a control system based on the received signal.The P51-50-A-Y-P-4.5OVP-000-000 transducer has a wide range of applications. It is used in the industrial environment for measuring pressure or process control, in the medical industry for measuring pressure or flow rate, and in research into air flow. The accuracy level of the unit makes it suitable for use in critical applications where very precise measurements are required. In addition, the transducer’s ability to withstand a wide range of temperature makes it suitable for use in harsh and changing environments.The P51-50-A-Y-P-4.5OVP-000-000 pressure transducer is a reliable and robust device that is suitable for use in a wide range of applications. The transducer combines the primary sensing element, signal conditioning circuitry, and output controller into one unit, which makes it easy to install and use. The accuracy level of the transducer makes it suitable for use in critical applications, while its ability to withstand a wide range of temperatures makes it suitable for use in harsh and changing environments. The P51-50-A-Y-P-4.5OVP-000-000 is an ideal pressure transducer for measuring pressure, pressure differences, or flow rates in a variety of different settings.

The specific data is subject to PDF, and the above content is for reference

Latest Products
9781101

SST PRESSURE TRANSDUCERPressure Sensor

9781101 Allicdata Electronics
IPSU-G1003-5

PRSSR TRNS 0-100BR 4-20MA DINPressure Se...

IPSU-G1003-5 Allicdata Electronics
SSCSLNT001BD3A3

BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCSLNT001BD3A3 Allicdata Electronics
SSCMRRN005NDAA5

BRD MNT PRESSURE SENSORSPressure Sensor ...

SSCMRRN005NDAA5 Allicdata Electronics
PX2EG1XX040BSCHX

HEAVY DUTY PRESSURE TRANSDUCERPressure S...

PX2EG1XX040BSCHX Allicdata Electronics
NBPMANS100MGUNV

BRD MNT PRESSURE SENSORSPressure Sensor ...

NBPMANS100MGUNV Allicdata Electronics