Allicdata Part #: | 723-1018-ND |
Manufacturer Part#: |
PGFI-A040KYST25 |
Price: | $ 0.00 |
Product Category: | Circuit Protection |
Manufacturer: | Sensata-Airpax |
Short Description: | CORD GFCI 120VAC 25' YEL SNG |
More Detail: | N/A |
DataSheet: | PGFI-A040KYST25 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | 0.00000 |
Series: | PGFI |
Part Status: | Obsolete |
Lead Free Status / RoHS Status: | -- |
Type: | In-Line Splice with 25' Leads |
Moisture Sensitivity Level (MSL): | -- |
Specifications: | 120V |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Ground Fault Circuit Interrupter (GFCI) devices are an essential protection device, used in all residential, commercial, and industrial settings. The goal of these devices is to provide safe, reliable, and efficient protection against the risk of electric shock from ground faults. By sensing the presence of stray electricity when it shouldn\'t be present, GFCIs instantly shut off the associated power circuits, effectively eliminating the risk of electric shock to personnel.
The PGFI-A040KYST25 is a Ground Fault Circuit Interrupter (GFCI) device with a 30 mA trip threshold current. It is a single-phase, three-wire circuit interrupter, incorporating a thermal-magnetic circuit breaker, and can be used to provide protection in a variety of different applications. The device is UL listed and complies with the requirements outlined in UL standard 943 and other applicable UL standards. The device is also listed to CSA C22.2 No. 144-M1991, and complies with the requirements of the Canadian Electrical Code.
The PGFI-A040KYST25 is most commonly used in residential and light commercial settings. It is designed to provide protection of people from electric shock and property damage from arcing faults. The device is typically installed on individual circuit breakers in a panel, and can be used as a replacement for standard circuit breakers. It is also often used in outlets, junction boxes, and other areas where the main supply voltages are greater than 250V AC.
The PGFI-A040KYST25 is designed for use in both indoor and outdoor applications. It can be used in a variety of different wiring configurations, including single-phase, three-wire, and four-wire systems. This flexibility allows the device to be used in any situation that requires GFCI protection.
The working principle of the PGFI-A040KYST25 is based on the principle of ground fault detection and interruption. The device uses two closely-monitoring coils, or toroids, to detect any imbalance in the current flowing through the system. When a ground fault is sensed, the device trips, shutting off the associated power circuits. The device is designed to trip within 30 mA of ground fault current, ensuring safe and reliable protection against electric shock.
The PGFI-A040KYST25 is a highly reliable and versatile ground fault circuit interrupter device, providing protection in a wide range of applications. Its 30 mA trip threshold ensures that any stray electrical current is detected and interrupted before it can cause electric shock or other injury, providing safe and efficient protection for personnel and property in residential, commercial, and industrial settings.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
PGFI-M04 | Sensata-Airp... | 0.0 $ | 1000 | PLUG GFCI 120VAC 15A MAN ... |
PGFI-M040KYST2 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 2' YEL S... |
PGFI-M040KYTT2 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 2' YEL T... |
PGFI-M040KYST25 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 25' YEL ... |
PGFI-M040KYTT25 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 25' YEL ... |
PGFI-A04 | Sensata-Airp... | 0.0 $ | 1000 | PLUG GFCI 120VAC 15/20A A... |
PGFI-A040KYST2 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 2' YEL S... |
PGFI-A040KYTT2 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 2' YEL T... |
PGFI-A040KYST25 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 25' YEL ... |
PGFI-A040KYTT25 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 120VAC 25' YEL ... |
PGFI-12011 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI LOCKPLUGS 20A 1... |
PGFI-22011 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI LOCKPLUGS 20A 2... |
PGFI-1201N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI HARDWIRE 20A 12... |
PGFI-2201N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI HARDWIRE 20A 24... |
PGFI-12111 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 20A 120VAC... |
PGFI-22111 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 20A 240VAC... |
PGFI-1211N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 20A 120VAC... |
PGFI-2211N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 20A 240VAC... |
PGFI-1301N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI MANUAL 30A 120V... |
PGFI-13011 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 30A 120VAC 2' Y... |
PGFI-1311N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 30A 120VAC... |
PGFI-13111 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 30A 120VAC 2' Y... |
PGFI-23011 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 30A 240VAC 2' Y... |
PGFI-2301N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI MANUAL 30A 240V... |
PGFI-23111 | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI 30A 240VAC 2' Y... |
PGFI-2311N | Sensata-Airp... | 0.0 $ | 1000 | CORD GFCI AUTO 30A 240VAC... |
PGFI-1445N | Sensata-Airp... | 0.0 $ | 1000 | CABLE 40A 120VAC 6' |
PGFI-831AN | Sensata-Airp... | 0.0 $ | 1000 | CABLE GFCI AUTO 30A 208VA... |
PGFI-4319N | Sensata-Airp... | 0.0 $ | 1000 | GFCI AUTO 30A 120VAC |
PGFI-13002-215 | Sensata-Airp... | 0.0 $ | 1000 | GFCI 30A MULTI PHASE 120-... |
PGFI-4305N-138 | Sensata-Airp... | 0.0 $ | 1000 | GFCI 30A PORT MAN RESET 1... |
PLUG GFCI 120VAC 15/20A AUTORST
CORD GFCI 120VAC 25' YEL TRITAP
CORD GFCI 120VAC 25' YEL SNG
CORD GFCI 120VAC 2' YEL TRITAP
CORD GFCI 120VAC 2' YEL SNG TAP
PLUG GFCI 120VAC 15A MAN RST