Allicdata Part #: | SU2D35UC-ND |
Manufacturer Part#: |
SU2D35UC |
Price: | $ 24.56 |
Product Category: | Circuit Protection |
Manufacturer: | Weidmuller |
Short Description: | CB PROTECTOR 1077 2P D 35A ACDC |
More Detail: | N/A |
DataSheet: | SU2D35UC Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 22.32720 |
Series: | SUxxxUC |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal Magnetic |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 35A |
Voltage Rating - AC: | 480V |
Voltage Rating - DC: | 125V |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | None |
Illumination Voltage (Nominal): | -- |
Mounting Type: | DIN Rail |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are electrical switches designed to protect circuits from short-circuits, overloads, and other hazardous electrical occurrences. The SU2D35UC is a popular circuit breaker that has been used in a wide range of industrial applications.
The SU2D35UC circuit breaker is a hydraulic-magnetic circuit breaker that has a breaking capacity of 35A. It provides a wide range of protection and is designed to quickly disconnect a faulted circuit from the power supply. Its hydraulic-magnetic design is also beneficial for applications that experience frequent on/off cycling or require occasional maintenance. The SU2D35UC provides a higher instantaneous interrupting current rating than other standard circuit breakers, which makes it suitable for applications with higher inrush currents.
The SU2D35UC is available in two models - Thermal and Thermal-Magnetic. The Thermal model is designed for motors and other high power-consuming applications, while the Thermal-Magnetic model provides additional protection against overcurrents. Both models feature a two-pole plug-in design, which allows for easy installation in panel boards and distribution boards. The circuit breaker also has a manual reset mode for trouble shooting and maintenance.
The working principle of the SU2D35UC circuit breaker is based upon the principle of magnetism. When circuit current exceeds its rated value, a magnetic field is generated within the breaker. This magnetic field causes the internal contact points to open and disconnect the circuit from the power supply. The thermal model also has a thermal element that trips the breaker in case of an overload. The thermal element is designed to open the breaker when the circuit current exceeds its rated value for a given duration of time.
The SU2D35UC circuit breakers are widely used in commercial, industrial, and residential applications. They are typically installed in panel boards, distribution boards, switchboards, switchgears, rental panels, and many other electrical systems. They are also used in motor control centers, gensets, gas turbines, UPS systems, and other industrial equipment. The SU2D35UC circuit breaker provides a reliable, cost-effective solution for overcurrent protection and interrupting current ratings compared to other standard circuit breakers.
In conclusion, the SU2D35UC circuit breaker is a reliable and cost-effective circuit protection solution for a range of applications. Its wide range of protection, thermal-magnetic protection, and two-pole plug-in design make it a great choice for industrial and commercial applications. Its magnetic working principle is also beneficial for applications that experience frequent on/off cycling or require occasional maintenance.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
SU2D10UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 10... |
SU2D12UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 12... |
SU2D13UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 13... |
SU2D15UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 15... |
SU2D16UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 16... |
SU2D1UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 1A... |
SU2D20UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 20... |
SU2D25UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 25... |
SU2D2UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 2A... |
SU2D30UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 30... |
SU2D32UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 32... |
SU2D3UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 3A... |
SU2D40UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 40... |
SU2D4UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 4A... |
SU2D50UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 50... |
SU2D5UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 5A... |
SU2D60UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 60... |
SU2D6UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 6A... |
SU2D8UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 8A... |
SU2D35UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 35... |
SU2D63UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 63... |
SU2D7UC | Weidmuller | 24.58 $ | 1000 | CB PROTECTOR 277/480V D 2... |
SU2D05AC | Weidmuller | 28.49 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D10AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D12AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D13AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D15AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D16AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/ |
SU2D1AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D20AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D25AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D2AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D30AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D32AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D3AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D40AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D4AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D50AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D5AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D60AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/F CURVE/... |
CIRCUIT BREAKER MAG-HYDR LEVER
CIRCUIT BREAKER MAG-HYDR LEVER
CIR BRKR MAG-HYDR 200A 160VDC
CIR BRKR MAG-HYDR
CIRC BRKR THRM
CIR BRKR MAG-HYDR LEVER 10A