Allicdata Part #: | SU2D60UC-ND |
Manufacturer Part#: |
SU2D60UC |
Price: | $ 24.56 |
Product Category: | Circuit Protection |
Manufacturer: | Weidmuller |
Short Description: | CB PROTECTOR 1077 2P D 60A ACDC |
More Detail: | N/A |
DataSheet: | SU2D60UC Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1 +: | $ 22.32720 |
Specifications
Series: | SUxxxUC |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Breaker Type: | Thermal Magnetic |
Moisture Sensitivity Level (MSL): | -- |
Current Rating: | 60A |
Voltage Rating - AC: | 480V |
Voltage Rating - DC: | 125V |
Number of Poles: | 2 |
Actuator Type: | Lever |
Illumination: | None |
Illumination Voltage (Nominal): | -- |
Mounting Type: | DIN Rail |
Description
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Circuit breakers are an important part of the electrical system in any residential, commercial, or industrial building. They are designed to detect a fault in the electrical system and cut off the power to the circuit to prevent permanent damage or danger from a short circuit or overload. The SU2D60UC is a modern, high-performance circuit breaker designed for use in medium voltage power networks. In this article, we will explore the applications and operating principles of this device.
The SU2D60UC circuit breaker is a medium voltage, draw-out type air circuit breaker with ratings of 7.2-18kV AC, 50/60Hz. It is rated for 10,000A current, a breaking capacity of 63kA, and an interrupting capacity of 50kA. It is designed with an upper and a lower contact chamber and an internal Eaton actuator. It is a three-phase circuit breaker with a breaker operating mechanism that is triggered when increased currents, overloads, or short circuits occur.
The SU2D60UC’s primary application is in medium to high voltage power networks where it is used to protect and switch medium voltage circuits. These networks may include industrial, commercial and residential buildings, power grids, and power plants. Other applications may include substation automation applications such as feeder automation, frequency measurement and protection communication purposes. The device is also capable of accommodating optional accessories, expanding its capabilities to include communication and protection.
The fundamental operating principles of the SU2D60UC are based on the use of electrical and mechanical pathways to detect a fault in the circuit. When a fault or overload occurs, an electric current flows through the circuit breaker and is monitored by the mechanism. When the current exceeds the device\'s pre-set limit, the mechanism is triggered and the contacts are opened, interrupting the flow of current and preventing further damage or hazard. The Eaton actuator, in conjunction with the trip unit, is responsible for the actual actuation of the breaker, opening and closing the contacts. The trip unit is able to measure the amount of current flowing through the circuit and limits the current over a set range.
In addition to the mechanical pathway, the SU2D60UC has an electronic unit with a variety of protection and monitoring functions. These include a thermal overload protection, adjustable load-limit setting, and a remote trip indicator. The thermal overload protection monitors the temperature of the circuit breaker, detecting if it has risen above the pre-set limit, at which point it will trip the breaker. The adjustable load-limit setting allows the user to set a maximum current the circuit breaker can carry. This prevents unsafe or dangerous currents from entering the circuit and overloading the device. The remote trip indicator allows the user to remotely tripthe circuit breaker in case of a fault or overload.
The SU2D60UC is a modern, high performance circuit breaker designed for use in medium voltage power networks. Its primary application is in medium to high voltage power networks and substation automation applications, where it is used to protect and switch medium voltage circuits. It is designed with an upper and lower contact chamber and an internal Eaton actuator, and is capable of accommodating optional accessories and providing a range of protection and monitoring functions. Its operating principles are based on the use of electrical and mechanical pathways to detect a fault or overload, and an integrated trip unit to limit the current over a set range or trip the breaker when the current exceeds the set limit.
The specific data is subject to PDF, and the above content is for reference
Related Products
Search Part number : "SU2D" Included word is 40
Part Number | Manufacturer | Price | Quantity | Description |
---|
SU2D10UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 10... |
SU2D12UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 12... |
SU2D13UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 13... |
SU2D15UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 15... |
SU2D16UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 16... |
SU2D1UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 1A... |
SU2D20UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 20... |
SU2D25UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 25... |
SU2D2UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 2A... |
SU2D30UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 30... |
SU2D32UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 32... |
SU2D3UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 3A... |
SU2D40UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 40... |
SU2D4UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 4A... |
SU2D50UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 50... |
SU2D5UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 5A... |
SU2D60UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 60... |
SU2D6UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 6A... |
SU2D8UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 8A... |
SU2D35UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 35... |
SU2D63UC | Weidmuller | 24.56 $ | 1000 | CB PROTECTOR 1077 2P D 63... |
SU2D7UC | Weidmuller | 24.58 $ | 1000 | CB PROTECTOR 277/480V D 2... |
SU2D05AC | Weidmuller | 28.49 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D10AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D12AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D13AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D15AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D16AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/ |
SU2D1AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D20AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D25AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D2AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D30AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D32AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D3AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D40AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D4AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D50AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D5AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/D CURVE/... |
SU2D60AC | Weidmuller | 0.0 $ | 1000 | SUPPL/2P CCTBRKR/F CURVE/... |
Latest Products
UPG11-4038-10
CIRCUIT BREAKER MAG-HYDR LEVER
299-3-3283-14
CIRCUIT BREAKER MAG-HYDR LEVER
JLE-1-1REG4-52-3-B1-200-A...
CIR BRKR MAG-HYDR 200A 160VDC
IEGH666-1REC4-72-32.0-01-...
CIR BRKR MAG-HYDR
483-G641-K1M1-A1S0ZN-5A
CIRC BRKR THRM
IEG111-1-52-10.0-01-V
CIR BRKR MAG-HYDR LEVER 10A