Specifications
Series: SUxxxUC
Part Status: Active
Lead Free Status / RoHS Status: --
Breaker Type: Thermal Magnetic
Moisture Sensitivity Level (MSL): --
Current Rating: 60A
Voltage Rating - AC: 480V
Voltage Rating - DC: 125V
Number of Poles: 2
Actuator Type: Lever
Illumination: None
Illumination Voltage (Nominal): --
Mounting Type: DIN Rail
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Circuit breakers are an important part of the electrical system in any residential, commercial, or industrial building. They are designed to detect a fault in the electrical system and cut off the power to the circuit to prevent permanent damage or danger from a short circuit or overload. The SU2D60UC is a modern, high-performance circuit breaker designed for use in medium voltage power networks. In this article, we will explore the applications and operating principles of this device.
The SU2D60UC circuit breaker is a medium voltage, draw-out type air circuit breaker with ratings of 7.2-18kV AC, 50/60Hz. It is rated for 10,000A current, a breaking capacity of 63kA, and an interrupting capacity of 50kA. It is designed with an upper and a lower contact chamber and an internal Eaton actuator. It is a three-phase circuit breaker with a breaker operating mechanism that is triggered when increased currents, overloads, or short circuits occur.
The SU2D60UC’s primary application is in medium to high voltage power networks where it is used to protect and switch medium voltage circuits. These networks may include industrial, commercial and residential buildings, power grids, and power plants. Other applications may include substation automation applications such as feeder automation, frequency measurement and protection communication purposes. The device is also capable of accommodating optional accessories, expanding its capabilities to include communication and protection.
The fundamental operating principles of the SU2D60UC are based on the use of electrical and mechanical pathways to detect a fault in the circuit. When a fault or overload occurs, an electric current flows through the circuit breaker and is monitored by the mechanism. When the current exceeds the device\'s pre-set limit, the mechanism is triggered and the contacts are opened, interrupting the flow of current and preventing further damage or hazard. The Eaton actuator, in conjunction with the trip unit, is responsible for the actual actuation of the breaker, opening and closing the contacts. The trip unit is able to measure the amount of current flowing through the circuit and limits the current over a set range.
In addition to the mechanical pathway, the SU2D60UC has an electronic unit with a variety of protection and monitoring functions. These include a thermal overload protection, adjustable load-limit setting, and a remote trip indicator. The thermal overload protection monitors the temperature of the circuit breaker, detecting if it has risen above the pre-set limit, at which point it will trip the breaker. The adjustable load-limit setting allows the user to set a maximum current the circuit breaker can carry. This prevents unsafe or dangerous currents from entering the circuit and overloading the device. The remote trip indicator allows the user to remotely tripthe circuit breaker in case of a fault or overload.
The SU2D60UC is a modern, high performance circuit breaker designed for use in medium voltage power networks. Its primary application is in medium to high voltage power networks and substation automation applications, where it is used to protect and switch medium voltage circuits. It is designed with an upper and lower contact chamber and an internal Eaton actuator, and is capable of accommodating optional accessories and providing a range of protection and monitoring functions. Its operating principles are based on the use of electrical and mechanical pathways to detect a fault or overload, and an integrated trip unit to limit the current over a set range or trip the breaker when the current exceeds the set limit.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "SU2D" Included word is 40
Part Number Manufacturer Price Quantity Description
SU2D10UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 10...
SU2D12UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 12...
SU2D13UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 13...
SU2D15UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 15...
SU2D16UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 16...
SU2D1UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 1A...
SU2D20UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 20...
SU2D25UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 25...
SU2D2UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 2A...
SU2D30UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 30...
SU2D32UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 32...
SU2D3UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 3A...
SU2D40UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 40...
SU2D4UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 4A...
SU2D50UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 50...
SU2D5UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 5A...
SU2D60UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 60...
SU2D6UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 6A...
SU2D8UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 8A...
SU2D35UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 35...
SU2D63UC Weidmuller 24.56 $ 1000 CB PROTECTOR 1077 2P D 63...
SU2D7UC Weidmuller 24.58 $ 1000 CB PROTECTOR 277/480V D 2...
SU2D05AC Weidmuller 28.49 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D10AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D12AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D13AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D15AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D16AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/
SU2D1AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D20AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D25AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D2AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D30AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D32AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D3AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D40AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D4AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D50AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D5AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/D CURVE/...
SU2D60AC Weidmuller 0.0 $ 1000 SUPPL/2P CCTBRKR/F CURVE/...
Latest Products
UPG11-4038-10

CIRCUIT BREAKER MAG-HYDR LEVER

UPG11-4038-10 Allicdata Electronics
299-3-3283-14

CIRCUIT BREAKER MAG-HYDR LEVER

299-3-3283-14 Allicdata Electronics
JLE-1-1REG4-52-3-B1-200-A...

CIR BRKR MAG-HYDR 200A 160VDC

JLE-1-1REG4-52-3-B1-200-A-V Allicdata Electronics
IEGH666-1REC4-72-32.0-01-...

CIR BRKR MAG-HYDR

IEGH666-1REC4-72-32.0-01-V Allicdata Electronics
483-G641-K1M1-A1S0ZN-5A

CIRC BRKR THRM

483-G641-K1M1-A1S0ZN-5A Allicdata Electronics
IEG111-1-52-10.0-01-V

CIR BRKR MAG-HYDR LEVER 10A

IEG111-1-52-10.0-01-V Allicdata Electronics