| Allicdata Part #: | 2026-20-C2LF-ND |
| Manufacturer Part#: |
2026-20-C2LF |
| Price: | $ 0.68 |
| Product Category: | Circuit Protection |
| Manufacturer: | Bourns Inc. |
| Short Description: | GDT 200V 20% 20KA THROUGH HOLE |
| More Detail: | Gas Discharge Tube 200V 20000A (20kA) ±20% 3 Pole ... |
| DataSheet: | 2026-20-C2LF Datasheet/PDF |
| Quantity: | 1000 |
| Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
| Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
| 1000 +: | $ 0.61945 |
| Series: | TRIGARD® 2026 |
| Packaging: | Bulk |
| Lead Free Status / RoHS Status: | -- |
| Part Status: | Active |
| Moisture Sensitivity Level (MSL): | -- |
| Voltage - DC Spark Over (Nom): | 200V |
| Impulse Discharge Current (8/20µs): | 20000A (20kA) |
| Tolerance: | ±20% |
| Number of Poles: | 3 |
| Fail Short: | No |
| Mounting Type: | Through Hole |
| Package / Case: | Axial Cylinder, 3 Lead (Radial Bend) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
In the field of power engineering, the term "Gas Discharge Tubes (GDTs)" encompases a variety of devices used to provide electrical protection. GDTs are commonly used to protect power transmission lines and electronic circuits from transient voltage, such as lightning surges or high voltage switching. The 2026-20- C2LF is a type of GDT, specifically designed for lightning protection.
The 2026-20-C2LF achieves lightning surge protection through a combination of physical, electrical, and chemical principles. The physical principle behind its operation is the distinctive shape of the device itself. The 2026-20-C2LF is designed to have a narrow upper portion that contains a gas tube and a wide lower portion that contains two electrodes. The gas tube is filled with a special inert gas mixture, while the electrodes are made of a proprietary alloy that helps to regulate the electrical current.
The electrical principle underlying GDT operation is based on the physical characteristics of the device. As voltage increases, the current passing through the electrodes increases and triggers an ionization process. This process generates a current pulse that is conducted through the gas tube to the electrodes, gradually reducing its voltage. This process is known as "dielectric breakdown" and is responsible for the protection offered by GDTs.
Finally, the 2026-20-C2LF relies on a chemical principle known as the "arc-quenching" effect. The presence of a special inert gas mixture in the gas tube helps to extinguish the current pulse as it passes through the device. This helps to reduce the voltage to safe levels, thereby preventing further damage. The presence of the proprietary alloy electrodes further enhances the effect by providing additional resistance and dissipating some of the electrical current.
In conclusion, the 2026-20-C2LF GDT offers superior lightning surge protection through a combination of physical, electrical, and chemical principles. The device\'s distinctive shape helps to limit peak current while its gas tube and special alloy electrodes provide additional resistance to the current pulse. This helps to reduce the voltage to safe levels, thereby protecting the equipment from further damage.
The specific data is subject to PDF, and the above content is for reference
| Part Number | Manufacturer | Price | Quantity | Description |
|---|
| 2026-15-C4LF | Bourns Inc. | 0.68 $ | 1000 | GDT 150V 20% 20KA THROUGH... |
| 2026-07-C18F | Bourns Inc. | 0.88 $ | 1000 | GDT 75V 20% 20KA THROUGH ... |
| 2026-35-C8 | Bourns Inc. | 0.68 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
| 2026-40-A | Bourns Inc. | 0.61 $ | 1000 | GDT 400V 20% 20KAGas Disc... |
| 2026-40-C2FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 400V 20% 20KA T/H FAI... |
| 5-202680-3 | TE Connectiv... | 111.31 $ | 1000 | PLUG KIT 2 MODULE G-SERIE... |
| 2026-23-C18 | Bourns Inc. | 0.68 $ | 1000 | GDT 230V 20% 20KA THROUGH... |
| 2026-30-C18 | Bourns Inc. | 0.68 $ | 1000 | GDT 300V 20% 20KA THROUGH... |
| 2026-23-C3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 230V 20% 20KA THROUGH... |
| 2026-25-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 250V 20% 20KA T/H FAI... |
| 2026-09-C4LF | Bourns Inc. | 0.68 $ | 1000 | GDT 90V 20% 20KA THROUGH ... |
| 2026-35-A1F | Bourns Inc. | 0.88 $ | 1000 | GDT 350V 20% 20KA FAIL SH... |
| 2026-60-CLF | Bourns Inc. | 0.64 $ | 1000 | GDT 600V 20% 20KA THROUGH... |
| 2026-15-C18 | Bourns Inc. | 0.68 $ | 1000 | GDT 150V 20% 20KA THROUGH... |
| LED4-20265 | Varitronix | 8.73 $ | 137 | BACKLIGHT FOR TRANSFL GLA... |
| 3448-2026 | 3M | 1.55 $ | 1000 | CONN STRAIN RELIEF 26POS ... |
| 2026-07-C2 | Bourns Inc. | 1.51 $ | 811 | GDT 75V 20% 20KA THROUGH ... |
| 2026-09-CLF | Bourns Inc. | 1.42 $ | 321 | GDT 90V 20% 20KA THROUGH ... |
| 2026-15-C4 | Bourns Inc. | 0.68 $ | 1000 | GDT 150V 20% 20KA THROUGH... |
| 2026-47-C3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 470V 20% 20KA THROUGH... |
| MDLS-20265-SS-LV-S-LED-04-G | Varitronix | 0.0 $ | 1000 | LCD MODULE 20X2 SLV SUPRT... |
| 2026-25-C2LF | Bourns Inc. | 1.51 $ | 1971 | GDT 250V 20% 20KA THROUGH... |
| 2026-23-CLF | Bourns Inc. | 0.64 $ | 1000 | GDT 230V 20% 20KA THROUGH... |
| 2026-47-C2 | Bourns Inc. | 0.68 $ | 1000 | GDT 470V 20% 20KA THROUGH... |
| 2026-25-A1F | Bourns Inc. | 0.88 $ | 1000 | GDT 250V 20% 20KA FAIL SH... |
| MIKROE-2026 | MikroElektro... | 34.64 $ | 100 | HEXIWEAR SMART WATCH CONT... |
| 2026-25-C8 | Bourns Inc. | 0.68 $ | 1000 | GDT 250V 20% 20KA THROUGH... |
| RH35M-6/202667 | ebm-papst In... | 0.0 $ | 1000 | FAN IMP MTRZD 365X170MM 2... |
| 2026-30-C3LF | Bourns Inc. | 0.68 $ | 1000 | GDT 300V 20% 20KA THROUGH... |
| 2026-40-C2LF | Bourns Inc. | 0.68 $ | 1000 | GDT 400V 20% 20KA THROUGH... |
| M39003/03-2026/98 | Vishay Sprag... | 15.49 $ | 1000 | CAP TANT 220UF 20% 10V AX... |
| 2026-07-C13 | Bourns Inc. | 0.68 $ | 1000 | GDT 75V 20% 20KA THROUGH ... |
| 2026-35-C4LF | Bourns Inc. | 0.68 $ | 1000 | GDT 350V 20% 20KA THROUGH... |
| CHG-2026-001010-KCP | 3M | 4.12 $ | 1000 | CONN RECEPT IDC 26POS 28-... |
| 2026-25-C3 | Bourns Inc. | 0.68 $ | 1000 | GDT 250V 20% 20KA THROUGH... |
| 2026-25-CBLF | Bourns Inc. | 0.68 $ | 1000 | GDT 250V 20% 20KA THROUGH... |
| 2026-30-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 300V 20% 20KA T/H FAI... |
| 2026-33-C2F | Bourns Inc. | 0.88 $ | 1000 | GDT 330V 20% 20KA T/H FAI... |
| 2026-07-C2FLF | Bourns Inc. | 0.88 $ | 1000 | GDT 75V 20% 20KA T/H FAIL... |
| DMC-20261NY-LY-CME-CPN | Kyocera Inte... | 0.0 $ | 1000 | LCD MOD CHAR 20X2 TRANSMI... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
2026-20-C2LF Datasheet/PDF