Allicdata Part #: | 2030-23T-SMLF-ND |
Manufacturer Part#: |
2030-23T-SMLF |
Price: | $ 0.81 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GDT 185V 4KA SURFACE MOUNT |
More Detail: | Gas Discharge Tube 185V 4000A (4kA) 3 Pole Surfac... |
DataSheet: | 2030-23T-SMLF Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.73616 |
Series: | 2030-xxT-SM |
Packaging: | Bulk |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 185V |
Impulse Discharge Current (8/20µs): | 4000A (4kA) |
Tolerance: | -- |
Number of Poles: | 3 |
Fail Short: | No |
Mounting Type: | Surface Mount |
Package / Case: | 3-SMD Cylinder Square End |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDT)
Gas Discharge Tube Arresters (GDTs) are used in many electrical and electronic systems to protect against electrical transients caused by lightning. GDTs act as an auxiliary line to the main line and can dissipate large amounts of electrical energy without damage.
A gas discharge tube is a glass tube filled with a gas, usually argon or a mixture of argon and mercury vapor; it is also known as an over-voltage protector or surge protector. The tube is connected to the main line in series, and when an over-voltage transient is detected, the tube can discharge its energy to the ground. This discharges the voltage before it can reach and damage the components of the system.
GDTs are typically used in telecommunications systems, power systems, and radio frequency systems. An example of a GDT application is in a telecommunications system, where electrical transients could cause a momentary communication disruption. In power systems, GDTs can help protect sensitive equipment. In radio frequency and microwave systems, GDTs can protect against over-voltage interference.
GDTs have been used since the 1950s, and their technology has been continually improving. The basic working principle is the same, however: the GDT monitors the AC or DC voltage on the main power lines and detects any changes. When a change is detected, the GDT discharges a high-voltage impulse to the ground. This impulse dissipates the energy of the transient, preventing it from reaching the circuitry.
GDTs have a number of advantages. They are low-cost and reliable, and their quick-response time is one of their key features. Additionally, they are very efficient at dissipating energy and can handle very high levels of transient. GDTs are also relatively simple to install and maintain.
GDTs are also commonly used in applications such as railroad signaling devices, motion control systems, and security systems. GDTs can provide protection against transients that could otherwise damage the system. In motion control systems, for example, transients can cause unexpected stops or sudden direction changes which can lead to serious damage or even catastrophes. In security systems, GDTs can protect against transients that can cause false alarms.
GDTs are an important component of many electrical and electronic systems, and their application is becoming increasingly widespread. As technology advances, GDTs will become even more important. In the future, their applications may go beyond protection from transients, and they may be used as part of smart grids and other advanced applications.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
PTV09A-2030F-A103 | Bourns Inc. | 0.42 $ | 1000 | POT 10K OHM 1/20W CARBON ... |
PTV09A-2030F-B503 | Bourns Inc. | 0.42 $ | 1000 | POT 50K OHM 1/20W CARBON ... |
PTV09A-2030U-A102 | Bourns Inc. | 0.42 $ | 1000 | POT 1K OHM 1/20W CARBON L... |
PTV09A-2030U-B102 | Bourns Inc. | 0.42 $ | 1000 | POT 1K OHM 1/20W CARBON L... |
PTV09A-2030U-B104 | Bourns Inc. | 0.42 $ | 1000 | POT 100K OHM 1/20W CARBON... |
LMH060-2000-40F9-20300TW | Cree Inc. | 119.83 $ | 1000 | LED MOD 2000LM 4000K 230V... |
LMH060-2900-30F9-20300TW | Cree Inc. | 151.19 $ | 1000 | LED MOD 2900LM 3000K 230V... |
LMH060-2900-40F9-20300TW | Cree Inc. | 151.19 $ | 1000 | LED MOD 2900LM 4000K 230V... |
71661-2030 | Molex, LLC | 1.99 $ | 1000 | CONN PLUG RT ANG 30POS .0... |
15-92-2030 | Molex, LLC | 2.16 $ | 1000 | CONN PLUG VERTICAL 30POS ... |
PT-2030P-PQ | Mallory Sona... | 1.1 $ | 9 | AUDIO PIEZO TRANSDUCER 1-... |
EV_IDG-2030U | TDK InvenSen... | 42.45 $ | 1000 | EVAL BOARD* Sensor Evalu... |
55660-20302 | Amphenol FCI | 0.0 $ | 1000 | CONN SKT DIMM 184POS PCB1... |
10002394-20304 | Amphenol FCI | 0.0 $ | 1000 | CONN SKT DIMM 184POS PCB1... |
55660-20304 | Amphenol FCI | 0.0 $ | 1000 | CONN SKT DIMM 184POS PCB1... |
DEA252400BT-2030A1 | TDK Corporat... | -- | 2000 | FILTER BANDPASS 2.4GHZ WL... |
LMH060-2000-30F9-20300TW | Cree Inc. | 0.0 $ | 1000 | LED MOD 2000LM 3000K 230V... |
IEGZXF66-30808-2030 | Sensata-Airp... | 60.29 $ | 1000 | CIR BRKR MAG-HYDR ROCKER |
2030111200 | Dialight | 0.0 $ | 1000 | CAP MINI DIMMER PANEL IND... |
2030131200 | Dialight | 0.0 $ | 1000 | CAP MINI DIMMER PANEL IND... |
E-203064-10-9 | TE Connectiv... | 0.0 $ | 1000 | LABEL ID PRODUCT |
2030-15T-SM-RPLF | Bourns Inc. | 0.0 $ | 1000 | GDT 60V 4KA SURFACE MOUNT... |
2030-23T-SMLF | Bourns Inc. | 0.81 $ | 1000 | GDT 185V 4KA SURFACE MOUN... |
2030-42T-SMLF | Bourns Inc. | 0.95 $ | 1000 | GDT 360V 4KA SURFACE MOUN... |
2030.0025 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 2.5A 125VAC/... |
2030.0024 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 2A 125VAC/VD... |
2030.0020 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 800MA 125VAC... |
2030.0026 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 3.15A 125VAC... |
2030.0021 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 1A 125VAC/VD... |
2030.0022 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 1.25A 125VAC... |
2030.0023 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 1.6A 125VAC/... |
2030.0016 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 500MA 125VAC... |
2030.0017 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 630MA 125VAC... |
2030.0014 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 315MA 125VAC... |
2030.0015 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 400MA 125VAC... |
2030.0013 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 250MA 125VAC... |
2030.0018 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 710MA 125VAC... |
2030.0019 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 750MA 125VAC... |
2030.0256 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 3.15A 125VAC... |
2030.0543 | Schurter Inc... | 0.0 $ | 1000 | FUSE BRD MNT 250MA 125VAC... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...