Allicdata Part #: | 2056-60-B2LF-ND |
Manufacturer Part#: |
2056-60-B2LF |
Price: | $ 0.46 |
Product Category: | Circuit Protection |
Manufacturer: | Bourns Inc. |
Short Description: | GDT 600V 20% 5KA THROUGH HOLE |
More Detail: | Gas Discharge Tube 600V 5000A (5kA) ±20% 3 Pole Th... |
DataSheet: | 2056-60-B2LF Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
Moisture Sensitivity Level (MSL): | 1 (Unlimited) |
1000 +: | $ 0.41108 |
Series: | 2056 |
Packaging: | Tray |
Lead Free Status / RoHS Status: | -- |
Part Status: | Active |
Moisture Sensitivity Level (MSL): | -- |
Voltage - DC Spark Over (Nom): | 600V |
Impulse Discharge Current (8/20µs): | 5000A (5kA) |
Tolerance: | ±20% |
Number of Poles: | 3 |
Fail Short: | No |
Mounting Type: | Through Hole |
Package / Case: | Axial Cylinder, 3 Lead (Radial Bend) |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Gas Discharge Tube Arresters (GDTs) are devices which prevent surges in electrical transmission lines by absorbing the surge and then clasps it off the circuit. The 2056-60-B2LF is a GDT which is used in a variety of applications from industrial power systems to household appliances. This article will discuss the application field and working principle of the 2056-60-B2LF GDT.
Application Field
The 2056-60-B2LF GDT is an overvolting protection device which is used for a variety of applications. They are used in electrical systems such as those powering industrial machineries, medical devices, electronic equipment, and household appliances. The GDT plays an important role in these systems as a surge protector as any overvoltage surges could damage the electronics and cause permanent damage. The GDT is designed to allow normal electrical flow, and then divert any overvoltage surges away from the circuit, thus protecting it from becoming damaged.
Working Principle
The GDT works by using a gas discharge tube or a spark gap. A gas discharge tube consists of a sealed tube filled with an inert gas such as argon or nitrogen. The internal electrodes are also filled with the inert gas at moderate pressure. The electrodes are then connected to an external circuit, and the tube is charged with an electrical current. When the voltage of the circuit rises above the set level, the gas in the tube begins to ionize and a spark is created even if the current has decreased. The spark reaches the external electrodes, allowing the current to flow out of the tube and reducing the voltage of the circuit.
The amount of current that is diverted away from the circuit is determined by the size and shape of the gas discharge tube. The spark gap of the GDT also plays an important role in determining the amount of current that is dissipated. The spark gap is a gap between two electrodes which can be adjusted to allow less or more current to be diverted away from the circuit.
When the 2056-60-B2LF GDT is used in a circuit, it is important to make sure that the correct size and shape of the spark gap is chosen for the particular application. This will ensure that the GDT can effectively protect the circuit from damaging overvoltage surges.
Conclusion
The 2056-60-B2LF GDT is an important device which can be used for a variety of applications. It is capable of diverting damaging overvoltage surges away from a circuit and preventing it from becoming damaged. It works by using a spark gap to divert the current away from the circuit. The size and shape of the spark gap is important in determining the amount of current that is dissipated. By choosing the correct size and shape of the spark gap, the 2056-60-B2LF GDT can effectively protect circuits and ensure the safety of electronics.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
CY3250-20566 | Cypress Semi... | 64.96 $ | 4 | KIT EMULATION ICE POD PSO... |
205628-3 | TE Connectiv... | 27.88 $ | 1000 | AUTOWIRE KIT,15 POS,25 X ... |
205629-9 | TE Connectiv... | 43.3 $ | 1000 | CONN PLUG 36POS M SERIES |
205629-1 | TE Connectiv... | 45.27 $ | 1000 | CONN PLUG 36POS M SERIES |
205629-3 | TE Connectiv... | 53.33 $ | 1000 | CONN PLUG 36POS M SERIES |
205694-1 | TE Connectiv... | 0.0 $ | 1000 | HDR PIN ASSY, KEYING, LON... |
VB10-2056 | Cinch Connec... | 2.48 $ | 1000 | CONN BNC PLUG STR CRIMPBN... |
205689-2 | TE Connectiv... | 12.8 $ | 604 | CONN PLUG 28 POS PANEL MT... |
205690-2 | TE Connectiv... | 13.49 $ | 247 | CONN RECEPT BLOCK 28POS M... |
2056-440-AL | RAF Electron... | 0.35 $ | 15657 | HEX STANDOFF #4-40 ALUM 7... |
2056T-440-AL | RAF Electron... | 0.35 $ | 2929 | HEX STANDOFF #4-40 ALUM 1... |
2056-440-AL-7 | RAF Electron... | 0.36 $ | 6657 | HEX STANDOFF #4-40 ALUM 7... |
2056-256-AL-7 | RAF Electron... | 0.36 $ | 3452 | HEX STANDOFF #2-56 ALUM 7... |
2056T-440-AL-7 | RAF Electron... | 0.36 $ | 4712 | HEX STANDOFF #4-40 ALUM 1... |
2056T-256-AL | RAF Electron... | 0.57 $ | 1425 | HEX STANDOFF #2-56 ALUM 1... |
2056T-256-AL-7 | RAF Electron... | 0.6 $ | 1495 | HEX STANDOFF #2-56 ALUM 1... |
2056-256-N | RAF Electron... | 1.15 $ | 1925 | HEX STANDOFF #2-56 NYLON ... |
2056T-256-SS | RAF Electron... | 2.13 $ | 300 | HEX STANDOFF #2-56 SS 11.... |
2056-440-AL-6 | RAF Electron... | 0.64 $ | 1000 | HEX STANDOFF #4-40 ALUM 7... |
2056-440-S-12 | RAF Electron... | 0.75 $ | 614 | HEX STANDOFF #4-40 STEEL ... |
2056-440-SS | RAF Electron... | 0.76 $ | 654 | HEX STANDOFF #4-40 SS 7/1... |
2056-440-N | RAF Electron... | 1.15 $ | 931 | HEX STANDOFF #4-40 NYLON ... |
SR-2056B | Essentra Com... | 0.39 $ | 3000 | RIVET SNAP 0.220" NYLON B... |
SR-2056W | Essentra Com... | 0.39 $ | 3000 | RIVET SNAP 0.220" NYLON W... |
SRVO-2056B | Essentra Com... | 0.22 $ | 1000 | RIVET SNAP 0.220" NYLON B... |
PGC-2056 | Littelfuse I... | 73.81 $ | 1000 | 200:5 CT 2.2" ID 55MM |
205607-2 | TE Connectiv... | 6.26 $ | 282 | PIN BLK,15 POSN,AUTOWIRE1... |
205606-3 | TE Connectiv... | 8.36 $ | 298 | 15 POS. SOC. BLOCK15 Posi... |
2056-14-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 145V 20% 5KAGas Disch... |
2056-35-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 350V 20% 5KAGas Disch... |
2056-42-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 420V 20% 5KAGas Disch... |
2056-20-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 200V 20% 5KAGas Disch... |
2056-23-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 230V 20% 5KAGas Disch... |
2056-25-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 250V 20% 5KAGas Disch... |
2056-40-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 400V 20% 5KAGas Disch... |
2056-47-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 470V 20% 5KAGas Disch... |
2056-60-ALF | Bourns Inc. | 0.41 $ | 1000 | GDT 600V 20% 5KAGas Disch... |
2056-09-B3LF | Bourns Inc. | 0.46 $ | 1000 | GDT 90V 20% 5KA THROUGH H... |
2056-20-B3LF | Bourns Inc. | 0.46 $ | 1000 | GDT 200V 20% 5KA THROUGH ... |
2056-23-B3LF | Bourns Inc. | 0.46 $ | 1000 | GDT 230V 20% 5KA THROUGH ... |
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...
GAS DISCHARGE TUBEGas Discharge Tube ...