Allicdata Part #: | 2806210-ND |
Manufacturer Part#: |
2806210 |
Price: | $ 502.43 |
Product Category: | Industrial Controls |
Manufacturer: | Phoenix Contact |
Short Description: | CONN TERM BLOCK |
More Detail: | N/A |
DataSheet: | 2806210 Datasheet/PDF |
Quantity: | 1000 |
Lead Free Status / RoHS Status: | Lead free / RoHS Compliant |
1 +: | $ 456.75000 |
Series: | * |
Part Status: | Active |
Lead Free Status / RoHS Status: | -- |
Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us: sales@allicdata.com
Current/Voltage transducer (CVT) systems are mainly digital devices used to measure, monitor and control the current and voltage parameters of electric power systems. The 2806210 CVT has a wide range of applications in diverse industries and can be used in different environments. This article will discuss the uses, working principle, and deployment of this transducer system.
Applications
The 2806210 transducer system is used in many different applications. It can be used for ac and dc monitoring, power system fault protection, load balancing, harmonic distortion analysis, power system stability improvement, motor control, and state estimation. This multi-functional device can be used in a wide range of projects that involve electric power systems where high accuracy measurement and control is desired. Some of the key benefits of the 2806210 CVT system include reliability, accuracy, and cost effectiveness.
This transducer can be used in quasi-frequency measurement, process control, utility grid control, power system fault protection, load balancing, power system stability improvement, motor control, state estimation, harmonic distortion analysis, and other related applications. For instance, the 2806210 transducer system can be used to automatically detect power system faults and abnormality in industrial plants and to monitor the power supply parameters and make adjustments accordingly. Additionally, it is widely used in utility grid control systems to ensure accurate power distribution in terms of voltage and current.
Working Principle
The 2806210 transducer system is designed to measure and monitor current and voltage values of electric power systems. It can measure both ac and dc currents. When ac current is measured, the device works as an analog-to-digital converter and measures the RMS values of the current and voltage. In the case of dc current, it works as a voltage-to-current converter. It can also be programmed to measure both ac and dc parameters simultaneously.
The device works by converting an alternating current or voltage to a digital signal. The transducer consists of a resistor, capacitor, and inductor that work together to convert the signal. The resistor measures the current, while the capacitor measures the voltage. The inductor acts as a filter to suppress high frequency noise that could affect the accuracy of the signal. The transducer then converts the signal to a corresponding digital signal.
The 2806210 transducer system also features over-voltage and over-current protection that is used to protect the digital signals from reaching a dangerous level. This ensures that the accuracy of the signal is maintained. Additionally, the device is equipped with an isolated output terminal that enables the system to be connected to a wide range of power systems.
Deployment
The 2806210 transducer system can be deployed in different scenarios depending on the application. It can be used in both pole-mounted and wall-mounted scenarios. For pole-mounted applications, the transducer should be mounted on the pole and connected to the power system using an appropriate connection cable. For wall-mounted applications, the device should be mounted on the wall in a suitable enclosure and connected to the power system using a suitable cable.
Additionally, the device should be configured properly before it is deployed. This includes setting the input voltage range and setting the output voltage range. It is also necessary to ensure that the device is properly monitored and maintained in order to ensure its reliable and accurate operation.
The 2806210 transducer system is a reliable and accurate device that has a wide range of applications. It can be used to measure and monitor current and voltage parameters of electric power systems and generate digital signals for further processing or evaluation. The device has a wide range of deployment scenarios, can be configured easily, and is easy to maintain and monitor.
The specific data is subject to PDF, and the above content is for reference
Part Number | Manufacturer | Price | Quantity | Description |
---|
2806-2-00-01-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-2-00-50-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-3-00-01-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-3-00-50-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-2-00-80-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SNGTerminal T... |
2806-3-00-80-00-00-07-0 | Mill-Max Man... | 0.46 $ | 1000 | TERM TURRET SNGTerminal T... |
2806-1-00-01-00-00-07-0 | Mill-Max Man... | 0.49 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-1-00-50-00-00-07-0 | Mill-Max Man... | 0.49 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-1-00-80-00-00-07-0 | Mill-Max Man... | 0.49 $ | 1000 | TERM TURRET SNGTerminal T... |
2806-4-00-01-00-00-07-0 | Mill-Max Man... | 0.5 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-4-00-50-00-00-07-0 | Mill-Max Man... | 0.5 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-4-00-80-00-00-07-0 | Mill-Max Man... | 0.5 $ | 1000 | TERM TURRET SNGTerminal T... |
2806-2-00-44-00-00-07-0 | Mill-Max Man... | 0.5 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-3-00-44-00-00-07-0 | Mill-Max Man... | 0.5 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-1-00-44-00-00-07-0 | Mill-Max Man... | 0.53 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806-4-00-44-00-00-07-0 | Mill-Max Man... | 0.53 $ | 1000 | TERM TURRET SINGLE L=12.2... |
2806016 | Phoenix Cont... | 322.25 $ | 1000 | CONN TERM BLOCK |
2806210 | Phoenix Cont... | 502.43 $ | 1000 | CONN TERM BLOCK |
28065 | Parallax Inc... | 18.18 $ | 21 | LSM9DS1 9-AXIS IMU MODULE... |
TX18AB00-2806 | TE Connectiv... | 40.07 $ | 1000 | CONN BACKSHELL ADPT SZ 28... |
TXR18AB00-2806AI | TE Connectiv... | 37.05 $ | 1000 | CONN BACKSHELL ADPT SZ 28... |
IUGN66-28061-1 | Sensata-Airp... | 95.49 $ | 1000 | CIRCUIT BREAKER MAG-HYDR ... |
ADT-2806-SF-BMF-02 | Cinch Connec... | 0.0 $ | 1000 | CONN ADAPT SMA JACK TO BM... |
IUGN66-28061-2 | Sensata-Airp... | 68.77 $ | 1000 | CIR BRKR MAG-HYDR LEVER |
2806090 | Phoenix Cont... | 502.43 $ | 1000 | CONN TERM BLOCK |
2806223 | Phoenix Cont... | 0.69 $ | 1000 | CONN TERM BLOCK |
2806100 | Phoenix Cont... | 0.69 $ | 1000 | CONN TERM BLOCK |
2806236 | Phoenix Cont... | 0.69 $ | 1000 | CONN TERM BLOCK |
2806249 | Phoenix Cont... | 0.69 $ | 1000 | CONN TERM BLOCK |
28061-03 | Honeywell Se... | 0.0 $ | 1000 | COUNTER HOUR METER |
2806600 | Phoenix Cont... | 6.93 $ | 1000 | FUSE TR5 1A |
2806058 | Phoenix Cont... | 128.21 $ | 1000 | CONN TERM BLOCK |
2806061 | Phoenix Cont... | 139.99 $ | 1000 | CONN TERM BLOCK |
2806074 | Phoenix Cont... | 187.11 $ | 1000 | CONN TERM BLOCK |
2806087 | Phoenix Cont... | 304.92 $ | 1000 | CONN TERM BLOCK |
2806045 | Phoenix Cont... | 91.48 $ | 1000 | CONN TERM BLOCK |
28060-16 | Honeywell Se... | 63.92 $ | 1000 | COUNTER HOUR METER |
28061-01 | Honeywell Se... | 64.05 $ | 1000 | COUNTER HOUR METER |
PA-DSO-2806 | Logical Syst... | 15.2 $ | 1000 | ADAPTER 28-DIP BOARD- Soc... |
PA-DSO-2806-D420-28/2 | Logical Syst... | 21.96 $ | 1000 | ADAPTER 28DIP BD W/2 28SO... |
VOLT DIVIDER 3KV IN 200MV OUT
VOLT DIVIDER 5KV IN 200MV OUT
SIGNAL CONVERTER/DISCONNECTOR
TRANSDUCER MEASURING
TRANSDUCR AC VOLT 5V-OUT 500V-IN
VOLT DIVIDER 2KV IN 200MV OUT