BSPS3255TNCR Allicdata Electronics
Allicdata Part #:

BSPS3255TNCR-ND

Manufacturer Part#:

BSPS3255TNCR

Price: $ 0.69
Product Category:

Circuit Protection

Manufacturer: Eaton
Short Description: CMBND LGHTNNG CRRNT & SURGE1 REM
More Detail: Gas Discharge Tube 230V 3 Pole DIN Rail
DataSheet: BSPS3255TNCR datasheetBSPS3255TNCR Datasheet/PDF
Quantity: 1000
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Moisture Sensitivity Level (MSL): 1 (Unlimited)
1 +: $ 0.63000
Stock 1000Can Ship Immediately
$ 0.69
Specifications
Series: BPS
Packaging: Bulk 
Lead Free Status / RoHS Status: --
Part Status: Active
Moisture Sensitivity Level (MSL): --
Voltage - DC Spark Over (Nom): 230V
Impulse Discharge Current (8/20µs): --
Tolerance: --
Number of Poles: 3
Fail Short: No
Mounting Type: DIN Rail
Package / Case: Module
Description

Due to market price fluctuations, if you need to purchase or consult the price. You can contact us or emial to us:   sales@allicdata.com

Gas Discharge Tube Arresters (GDT) are designed to protect sensitive components from voltage transients, such as the voltage spikes caused by lightning strikes, the start-up or shut-down of power plants, and the sudden loss of grid supply. The BSPS3255TNCR belongs to this category of protection components and is designed to offer superior surge protection for sensitive equipment in a variety of applications. It offers high-voltage protection with low losses, while being compact and cost-effective.

The BSPS3255TNCR is a three-electrode gas discharge tube arranged in a TNC-R configuration. The electrodes are the anode and cathode electrodes, as well as the suppressor electrode. The anode electrode is the main surge protection element and is connected to the device\'s output. The cathode is connected to the ground, and the suppressor is connected to the device\'s input. This device is designed to limit the voltage to a safe level and redirect the surge current to the ground.

The BSPS3255TNCR application field covers fields such as information industry, communication systems, high-voltage power supplies, rectifiers, and other sensitive electronic equipment. In medical equipment, GDTs are used to protect patient monitors and electric surgical tools from being damaged by transient voltages. In telecommunication systems, GDTs are used in modems, routers, switches, and other devices to protect against interference from lightning strikes or electrical noise. Additionally, this device can be implemented to protect power supplies and rectifiers from surge current induced by sudden grid voltage changes, thereby preventing equipment damage and malfunction.

The working principle of the BSPS3255TNCR can be divided into three stages: charging, triggering, and discharging. During the charging stage, a current with a very low value flows between the cathode and anode electrodes. This current continues until the voltage between the electrodes reaches a certain level, called the breakdown or trigger voltage. At this point, a high-voltage spark jumps across the gap between the anode and cathode electrodes. This spark creates an electric arc that increases the voltage across the anode and cathode electrodes.

In the triggering stage, the electric arc is sustained when the voltage reaches the same level as the breakdown voltage. This stage is referred to as the avalanche voltage and is far higher than the breakdown voltage. This high voltage surge is diverted to the ground through the suppressor electrode, which is connected to the device\'s input. In the discharging stage, the electric arc between the electrodes is extinguished and the surge current is diverted to ground. This process helps protect the device and any connected equipment from potential damage due to transient voltages.

The BSPS3255TNCR is an effective device for protecting sensitive equipment from transient voltages. It offers superior surge protection with low losses, and is designed to limit voltage to a safe level and redirect surge current to ground. This makes it suitable for a variety of applications in fields such as the medical and telecommunication industries, and is also effective for protecting power supplies and rectifiers from transient grid voltages. With its compact design and cost-effectiveness, it is an ideal solution for protecting sensitive equipment from damage due to transient voltages.

The specific data is subject to PDF, and the above content is for reference

Related Products
Search Part number : "BSPS" Included word is 14
Part Number Manufacturer Price Quantity Description
BSPS1400WE Eaton 447.73 $ 1000 400V 1P SPARKGAP DIN SPD ...
BSPS1400WER Eaton 469.53 $ 1000 400V 1P SPARKGAP DIN SPD ...
BSPS2255TN Eaton 530.63 $ 1000 COMBIND LIGHTNING CURRENT...
BSPS1690WER Eaton 533.31 $ 1000 FUSE 690V 1P SPARKGAP DIN...
BSPS2255TT Eaton 544.23 $ 1000 COMBND LIGHTNNG CURRENT &...
BSPS2255TNR Eaton 552.18 $ 1000 CMBIND LGHTNG CRENT & SRG...
BSPS2255TTR Eaton 565.78 $ 1000 COMBND LGHTNG CURRNT & SU...
BSPS3255TNC Eaton 0.69 $ 1000 COMBND LIGHTNNG CURRENT &...
BSPS3255TNCR Eaton 0.69 $ 1000 CMBND LGHTNNG CRRNT & SUR...
BSPS31000PV Eaton 0.69 $ 1000 1000 VDC 3 POLE CONFIGURA...
BSPS4255TNS Eaton 0.69 $ 1000 COMBND LIGHTNNG CURRENT &...
BSPS4255TT Eaton 0.69 $ 1000 230/400V CMBND LIGHTNG CR...
BSPS4255TNSR Eaton 0.69 $ 1000 COMBND LIGHTNG CURRNT & S...
BSPS4255TTR Eaton 0.69 $ 1000 230/400V CMBIND LIGHTNG C...
Latest Products
B88069X9960B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9960B102 Allicdata Electronics
B88069X9630C152

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X9630C152 Allicdata Electronics
B88069X8591B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8591B102 Allicdata Electronics
B88069X8291S102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X8291S102 Allicdata Electronics
B88069X7831B502

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X7831B502 Allicdata Electronics
B88069X5131B102

GAS DISCHARGE TUBEGas Discharge Tube ...

B88069X5131B102 Allicdata Electronics